18341 E El Buho Pequeno
Gold Canyon, AZ 85118
602-283-2507

Local Reviews
for peoria, az

Rated 5.0 out of 5 stars based on 10 customer reviews

Great service very polite

Carlos was on time went right to the problem fixed the problem in minutes and made sure everything worked the right way !!!!!!!!

  • Overall Experience
  • Quality
  • Price
  • Convenience

  • Overall Experience
  • Quality
  • Price
  • Convenience

  • Overall Experience
  • Quality
  • Price
  • Convenience

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great Service!!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great and quick service!

Our service tech Carlos, was just the nicest guy and his apprentice likewise. Will definitely keep this number! As far as price, when you need parts that's not really up to the company and our part was quite a bit but they did a great job and it was our choice to fix or not. :)

  • Overall Experience
  • Quality
  • Price
  • Convenience

Perfect service

Carlos was great. Did everything he said he was going to and within the time frames he said he’d do it. Would absolutely use this company again and Carlos specifically.

  • Overall Experience
  • Quality
  • Price
  • Convenience

a great service

very satisfied

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service. On time, knowledgeable serviceman.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for peoria, az

Christopher M.

Christopher M. Job Checkin

CONCERN: Customer reports refrigerator is leaking water onto floor. CAUSE: Technician inspected water supply line from wall to refrigerator water valve. No leaks at supply hose. Inspected water valve for leaks, no leaks at water valve, inspected refrigerator micro tubing, found micro tubing failure. CORRECTION: Replaced and repaired refrigerator micro tubing and check for further leaks. NO LEAKS UPON COMPLETION.


Christopher M.

Christopher M. Job Checkin

CONCERN: Customer reports oven is not heating DIAGNOSTIC AND CAUSE: Tested for proper voltage from wall outlet to terminal block Voltage good. Tested voltage from terminal block to control, voltage good. Tested voltage from control to ignitor, voltage good. Found oven ignitor has electrical short. CORRECTION: Replaced ignitor and tested, operation now normal.


Christopher M.

Christopher M. Job Checkin

Installed customer supplied parts.


Christopher M.

Christopher M. Job Checkin

CONCERN: Customer reports washer is leaking water onto floor. CAUSE: Washer drain hose failed. CORRECTION: Replaced washer drain hose and tested, operation now normal. NO LEAKS UPON COMPLETION.


Christopher M.

Christopher M. Job Checkin

CONCERN: Customer reports Refrigerator is not cooling properly. DIAGNOSTIC AND CAUSE: Test compressor operation to see if the compressor was running. Compressor was not running. Tested for voltage from adaptive defrost control board to compressor. No voltage from the main control board to the compressor. Cause of failure found ADC main control board shorted at the output line voltage to the compressor. CORRECTION: Replaced ADC main control board and tested. Operation now normal.


Christopher M.

Christopher M. Job Checkin

CONCERN: Customer reports washer is not working. CAUSE: Found washer main control board failed. CORRECTION: Replaced main control board and tested. Operation now normal.


Carlos V.

Carlos V. Job Checkin

CONCERN: Dryer takes too long to dry clothes, dryer does get hot though. DIAGNOSTIC AND CAUSE: Tested dryer for proper heater element operation. Heater operation is normal. Inspected heater thermostat operation for short cycling condition, thermostat is short cycling. Inspected dryer air flow at the duct flume, air flow is normal at this time, no signs of flow restriction. Cause, Wall vent clogged with lint. CORRECTION: Performed dryer vent cleaning, tested for restrictions, operation now normal


Carlos V.

Carlos V. Job Checkin

CONCERN: Customer reports refrigerator is leaking water. DIAGNOSTIC AND CAUSE: Inspected water supply line for leaks, no leaks at the refrigerator water supply line. Inspected internal water refrigerator water lines for leaks, internal refrigerator water line are normal at the time of inspection. Inspected refrigerator defrost drain line for water leaks, found the source of the leak coming from the refrigerator defrost drain. Removed freezer panel to inspect for clogged drain line. Found the defrost drain restricted with ice and debris. CORRECTION: Cleared the refrigerator defrost drain of ice, install drain kit and debris, operation now normal.


Carlos V.

Carlos V. Job Checkin

CONCERN: Customer reports KITCHEN AID refrigerator is not working properly. DIAGNOSTIC AND CAUSE: Inspected refrigerator for proper voltage supply, voltage is normal at the time of inspection. Inspected for proper voltage from terminal block to control, voltage is normal at the time of inspection. Inspected voltage from control to DC inverter, found voltage supply to the inverter normal however no voltage coming out of the inverter to the compressor. Found compressor inverter control board failed. CORRECTION: Replaced compressor inverter control board and tested. Operation now normal.


Carlos V.

Carlos V. Job Checkin

CONCERN: LG Dryer takes too long to dry clothes, dryer does get hot though. DIAGNOSTIC AND CAUSE: Tested dryer for proper heater element operation. Heater operation is normal. Inspected heater thermostat operation for short cycling condition, thermostat is short cycling. Inspected dryer air flow at the duct flume, air flow is normal at this time, no signs of flow restriction. Cause, Wall vent clogged with lint. CORRECTION: Performed dryer vent cleaning, tested for restrictions, operation now normal


Christopher M.

Christopher M. Job Checkin

CONCERN: Customer reports MAYTAG washer is not working properly. Model MVWC565FWODIAGNOSTIC AND CAUSE: Inspected wall outlet for voltage output, voltage output to washer normal at the time of inspection. Inspect voltage to control, voltage to control was normal at the time of inspection. Inspected signal from control to washer shift actuator, found washer shift actuator failed. CORRECTION: Replaced washer shift actuator and tested, operation now normal.


Christopher M.

Christopher M. Job Checkin

CONCERN: Customer reports KITCHEN AID refrigerator is leaking water onto floor. CAUSE: Technician inspected water supply line from wall to refrigerator water valve. No leaks at supply hose. Inspected water valve for leaks, no leaks at water valve, inspected refrigerator micro tubing, found micro tubing failure. CORRECTION: Replaced and repaired refrigerator micro tubing and check for further leaks. NO LEAKS UPON COMPLETION.


Carlos V.

Carlos V. Job Checkin

CONCERN: Customer reports Jenn Air refrigerator is leaking water onto floor. Model JCD2290HES DIAGNOSTIC AND CAUSE: Inspected water supply line to refrigerator for leaks, no leaks found at this time. Inspected water valve for leaks, found water valve failure. CORRECTION: Replaced water valve and tested. Operation now normal.


Carlos V.

Carlos V. Job Checkin

CONCERN: Customer reports LG dryer does not work. Model DLEX3470W DIAGNOSTIC AND CAUSE: Tested wall outlet for proper voltage, line voltage normal at time of inspection. Inspected terminal block for short or burnt wiring, terminal block and wiring normal. Inspected voltage to dryer controls, voltage normal at dryer controls. Inspected unit for missing neutral, Found neutral missing at dryer door switch. CORRECTION: Replaced dryer door switch and tested, operation now normal.


Carlos V.

Carlos V. Job Checkin

CONCERN: Dishwasher does not respond to commands. CAUSE: Touch pad Failure. CORRECTION: Replaced touch pad and tested, operation now normal.