18341 E El Buho Pequeno
Gold Canyon, AZ 85118
602-283-2507

Local Reviews
for queen creek, az

Rated 4.9 out of 5 stars based on 20 customer reviews

Great Service

  • Overall Experience
  • Quality
  • Price
  • Convenience

Amazing Service!!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Very friendly

Very prompt and amazing service

  • Overall Experience
  • Quality
  • Price
  • Convenience

Friendly, with a flexible schedule.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great Service

Steve is always thorough and diligent.


Response from Affordable Appliance Repair:

Shawn, Thank your so much for letting us know how the technician did for you, it is greatly appreciated.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Awesome customer service!

Steve was fantastic! He first returned my call in a timely manner, offered to come see my machine the SAME DAY, and arrived right on time. He was obviously knowledgeable, and did not up charge me on anything beyond the cause of my call. Overall wonderful experience during a stressful time. Thank you, Steve!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Always amazing service!

Recently called for service on our dryer. Steve came out same day diagnosed the issue and repaired it. These guys are fantastic. I wouldn't call anyone else for our appliance repairs.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Knowledgeable service and fair price

I would recommend this company for all my appliance repair needs

  • Overall Experience
  • Quality
  • Price
  • Convenience

Fantastic Service

Steve came out quickly and diagnosed the problem with our fridge. He found the part that we needed and gave us a quote and then came back to tell us he’d found it cheaper and would pass on the savings to us. He came back the next day to fix it and everything is working awesome! He was friendly and affordable and even fixed a few things that he noticed were amiss and didn’t charge us extra. Awesome experience!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great Service!!

Our Refrigerator stopped running. Steve came out and assessed the problem the morning after we called. The next day he returned with the parts and did the repairs. Steve offers great service at reasonable rates. I will definitely refer him to my friends and family.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for queen creek, az

Steve R.

Steve R. Job Checkin

CONCERN: Customer reports refrigerator is not as cold as it should be. DIAGNOSTIC AND CAUSE: Inspected wall outlet for proper voltage output, voltage output normal at the time of inspection. Inspected for voltage input at the compressor, compressor voltage input normal at the time of inspection. NOTE: Compressor was running and cooling unit down. Inspected voltage input at the condenser fan motor, input voltage was normal at the time of inspection. Found condenser fan motor Locked up and not running. CORRECTION: Replaced condenser fan motor and tested. Operation now normal.


Cameron D.

Cameron D. Job Checkin

CONCERN: Customer reports washer is not unlocking. CAUSE: Found washer control became stuck. CORRECTION: Performed hard reset and tested, operation now normal. No leaks upon completion. CONCERN: Customer reports dishwasher soap dispenser is not working. CAUSE: Found soap dispenser failed. CORRECTION: Replaced dishwasher soap dispenser and tested, operation now normal. No leaks upon completion.


Steve R.

Steve R. Job Checkin

CONCERN: Customer reports Glass Cooktop burner is not working CAUSE: Found burner element failed. CORRECTION: Replaced and tested, operation now normal. NOTE: Burner element receptacle is in good working order at the time of inspection. Infinite switch is performing as designed at the time of inspection.


Steve R.

Steve R. Job Checkin

CONCERN: Customer reports refrigerator is not as cold as it should be. DIAGNOSTIC AND CAUSE: Inspected wall outlet for proper voltage output, voltage output normal at the time of inspection. Inspected for voltage input at the compressor, compressor voltage input normal at the time of inspection. NOTE: Compressor was running and cooling unit down. Inspected voltage input at the condenser fan motor, input voltage was normal at the time of inspection. Found condenser fan motor Locked up and not running. CORRECTION: Replaced condenser fan motor and tested. Operation now normal.


Steve R.

Steve R. Job Checkin

CONCERN: Washer is not draining or spinning DIAGNOSTIC AND CAUSE: Inspected washer for proper output voltage from washer control to the washer motor, voltage output is normal at the time of testing. Inspected washer pump, Found washer pump failure. CORRECTION: Replaced washer pump and tested. Operation now normal.


Cameron D.

Cameron D. Job Checkin

CONCERN: Customer reports refrigerator is leaking water into ice maker. DIAGNOSTIC AND CAUSE: Inspected water supply line to icemaker, found inlet tube filled ice. Verified good water pressure to unit. Found water inlet valve failed. CORRECTION: Replaced water valve and tested. Operation now normal. NO LEAKS ON COMPLETION Installed steal braided water supply hose from wall to refrigerator water valve. Inspected for leaks and tested. NO LEAKS UPON COMPLETION.


Cameron D.

Cameron D. Job Checkin

CONCERN: Customer reports dryer is not heating. DIAGNOSTIC AND CAUSE: Inspected dryer for proper voltage from the wall to the cord terminal block, voltage normal. Inspected voltage from terminal block to dryer control assembly, voltage normal. Inspected continuity on all thermal safety thermostats, all thermal safeties are normal. Inspected continuity at heater element, found dryer heating element failed. CORRECTION: Replaced dryer heating element and tested. Operation now normal.


Steve R.

Steve R. Job Checkin

CONCERN: Customer reports freezer not cooling CAUSE: Found bad cold control unit. CORRECTION:Replaced Cold control and defrost timer,tested. Operation now normal.


Steve R.

Steve R. Job Checkin

CONCERN: Customer reports washer is leaking CAUSE: Found washer pressure switch hose loose CORRECTION: Repaired hose and tested, operation now normal.


Steve R.

Steve R. Job Checkin

CONCERN: Microwave display is not working. CAUSE: Found thermal safety shorted out. CORRECTION: Removed microwave from cabinet to access thermal safety. Replaced thermal safety and tested, operation now normal.


Steve R.

Steve R. Job Checkin

CONCERN: Customer reports microwave display is not working. CAUSE: Microwave display shorted. CORRECTION: Replaced microwave display with main board and tested, operation now normal.


Daren O.

Daren O. Job Checkin

CONCERN: Customer reports that the washer is not draining. DIAGNOSTIC AND CAUSE: Inspected wall outlet for proper voltage to washer, voltage output from wall outlet normal at the time of inspection. Inspected voltage output from control to washer drain pump, voltage to drain pump normal at the time of inspection. Found washer pump impeller was trying to turn however the technician found washer drain pump clogged with debris. CORRECTION: Removed drain pump to clear debris and re-installed, check for leaks and tested, Operation now normal.


Steve R.

Steve R. Job Checkin

CONCERN: Customer reports refrigerator seems to run all the time. CAUSE: Found condenser coils clogged with debris. CORRECTION: Clean condenser coils and tested, operation now normal.


Steve R.

Steve R. Job Checkin

CONCERN: Customer reports refrigerator section is not getting cold but freezer is still working properly. CAUSE: Found back panel and evaporator coils covered in frost. Tested the refrigerator defrost bi-metal thermostat for continuity, refrigerator defrost bi-metal continuity failed test. Refrigerator defrost bi-metal has electrical short. CORRECTION: Defrosted refrigerator evaporator coils and replaced defrost bi-metal thermostat. Operation now normal. CONCERN: Customer reports refrigerator is not working properly. CAUSE: Found refrigerator defrost timer failed. CORRECTION: Replaced refrigerator defrost timer and tested. Operation now normal.


Daren O.

Daren O. Job Checkin

CONCERN: Refrigerator section is not getting cold. DIAGNOSTIC AND CAUSE: Inspected voltage from terminal block to compressor, voltage normal at the time of inspection. Tested compressor operation, compressor operation normal at the time of inspection. Inspected voltage to evaporator fan motor, voltage normal at the time of inspection. Found evaporator fan motor failed. CORRECTION: Replaced refrigerator evaporator fan motor and tested. Operation now normal.