3421 S Halsted Place
Chandler, AZ 85286
602-283-2507

Local Reviews
for rio verde, az

Rated 5.0 out of 5 stars based on 6 customer reviews

Excellent service from David!! My only issue is communicating with staff when U called office to follow up on parts and scheduling.

David Riddle was exceptional!!!! He figured out the issues quickly and explained what needed ti happen. Communicating with the iffuce was my only concern.


Response from Affordable Appliance Repair:

Gail, Thank you so much, I will pass this along to David

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent Service

Everything was great. The service call as easy to schedule, and Dave showed up as promised. Took him about 1 hour, and he successfully fixed my dishwasher for a fair price.


Response from Affordable Appliance Repair:

RON, Very much appreciated, thank you!!!

  • Overall Experience
  • Quality
  • Price
  • Convenience

The best appliance service ever!

David is the best! Vast knowledge. Very likable - fair prices.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great, attentive, punctual service.

We had a great experience with this company and technician Joey. Professional, punctual, and Joey worked diligently to get our appliance repaired.


Response from Affordable Appliance Repair:

Lori, Thank you so much

  • Overall Experience
  • Quality
  • Price
  • Convenience

Good,competant service.

All went very well.


Response from Affordable Appliance Repair:

Cortland, Very grateful, thank you!!!!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent service!

Quickly and efficiently diagnosed our refrigerator/ freezer problem and repaired it. Highly recommended!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for rio verde, az

Spencer B.

Spencer B. Job Checkin

CONCERN: Customer reports Refrigerator is not cooling properly. DIAGNOSTIC AND CAUSE: Test compressor operation to see if the compressor was running. Compressor was not running. Tested for voltage from adaptive defrost control board to compressor. No voltage from the main control board to the compressor. Cause of failure found ADC main control board shorted at the output line voltage to the compressor. CORRECTION: Replaced ADC main control board and tested. Operation now normal. CONCERN: Customer reports refrigerator section is not getting cold but freezer is still working properly. CAUSE: Found back panel and evaporator coils covered in frost. Tested the refrigerator defrost bi-metal thermostat for continuity, refrigerator defrost bi-metal continuity failed test. Refrigerator defrost bi-metal has electrical short. CORRECTION: Defrosted refrigerator evaporator coils and replaced defrost bi-metal thermostat. Operation now normal.


Spencer B.

Spencer B. Job Checkin

CONCERN: Customer reports Refrigerator is not cooling properly. DIAGNOSTIC AND CAUSE: Test compressor operation to see if the compressor was running. Compressor was not running. Tested for voltage from adaptive defrost control board to compressor. No voltage from the main control board to the compressor. Cause of failure found ADC main control board shorted at the output line voltage to the compressor. CORRECTION: Replaced ADC main control board and tested. Operation now normal. CONCERN: Customer reports refrigerator section is not getting cold but freezer is still working properly. CAUSE: Found back panel and evaporator coils covered in frost. Tested the refrigerator defrost bi-metal thermostat for continuity, refrigerator defrost bi-metal continuity failed test. Refrigerator defrost bi-metal has electrical short. CORRECTION: Defrosted refrigerator evaporator coils and replaced defrost bi-metal thermostat. Operation now normal.


David R.

David R. Job Checkin

CONCERN: Customer reports ice maker is not making ice. DIAGNOSTIC AND CAUSE: Inspected water supply lines for leaks, no leaks from supply lines at the time of inspection. Inspected freezer for proper temperature output, temperature output in freezer normal at the time of inspection. Inspected for proper voltage to the ice maker, voltage to ice maker is normal at the time of inspection. Found voltage to the Ice maker normal however ice maker will not call for water from the refrigerator water valve. Found the ice maker failed. CORRECTION: Replaced ice maker and tested. Operation now normal. No leaks upon completion.


David R.

David R. Job Checkin

CONCERN: Customer reports oven is leaving lights on dimly even when off. CAUSE: Found main control board failure. CORRECTION: Gave estimate to replace. CONCERN: Customer reports oven is not working properly, lights do not shut off when switched off but stay dim. DIAGNOSTIC AND CAUSE: Inspected oven for proper wall outlet voltage to the oven, Output voltage normal at the time of inspection. Inspected voltage input at the main control board, input voltage to the main control board normal at the time of inspection. Found oven main control board failed. CORRECTION: Replaced and tested, operation now normal.


David R.

David R. Job Checkin

CONCERN: Customer reports oven is leaving lights on dimly even when off. CAUSE: Found main control board failure. CORRECTION: Gave estimate to replace CONCERN: Customer reports oven is not working properly, lights do not shut off when switched off but stay dim. DIAGNOSTIC AND CAUSE: Inspected oven for proper wall outlet voltage to the oven, Output voltage normal at the time of inspection. Inspected voltage input at the main control board, input voltage to the main control board normal at the time of inspection. Found oven main control board failed. CORRECTION: Replaced and tested, operation now normal.


Spencer B.

Spencer B. Job Checkin

CONCERN: Customer reports dishwasher door malfunctioning. DIAGNOSTIC AND CAUSE: Inspected door for visible damage, door is good condition at the time of inspection. Inspected door hinges for damage, no visible damage at the time of inspection. Inspected door springs and links, found dishwasher door hinge links failed. CORRECTION: Replaced link kit and tested. Operation now normal.


Spencer B.

Spencer B. Job Checkin

CONCERN: Customer reports refrigerator is leaking water onto floor. CAUSE: Technician inspected water supply line from wall to refrigerator water valve. No leaks at supply hose. Inspected water valve for leaks, no leaks at water valve, inspected refrigerator micro tubing, found micro tubing failure. Near water valve for both lines CORRECTION: Replaced micro tubes and repaired refrigerator micro tubing and check for further leaks. NO LEAKS UPON COMPLETION. CONCERN: Customer reports refrigerator seems to run all the time. CAUSE: Found condenser coils clogged with debris. CORRECTION: Clean condenser coils and tested, operation now normal.


Spencer B.

Spencer B. Job Checkin

CONCERN: Customer reports microwave is not working. DIAGNOSTIC AND CAUSE: Inspected power supply at the wall for 120V, voltage at supply line normal at time of inspection. Inspected control board for visible signs of shorts, no signs of shorts a the control board. Inspected microwave 20 amp safety fuse for shorts. Microwave fuse shorted. CORRECTION: Replaced microwave fuse and tested, operation now normal.


David R.

David R. Job Checkin

Installed customer supplied parts for dishwasher, including main control board, control panel with touch control, and drain pump.


David R.

David R. Job Checkin

CONCERN: Customer reports one of the freezer lights is out. CAUSE: Found LED light failed. CORRECTION: Replaced LED assembly and tested. Operation now normal.


David R.

David R. Job Checkin

CONCERN: Customer reports refrigerator lights are dim/flickering. CAUSE: Found one light fixture failed. CORRECTION: Replaced light fixture behind ice maker and tested. Operation now normal. No leaks upon completion.


David R.

David R. Job Checkin

CONCERN: Customer reports refrigerator is leaking intermittently. CAUSE: Found defrost drain line valve turned in wrong direction. CORRECTION: Adjusted valve and tested. Operation now normal. No leaks upon completion.


David R.

David R. Job Checkin

CONCERN: Customer reports refrigerator is leaking water. CAUSE: Unable to duplicate customer concern at this time. Refrigerator is performing as designed at time of inspection.


Joseph J.

Joseph J. Job Checkin

CONCERN: Customer reports Refrigerator is not cooling properly. DIAGNOSTIC AND CAUSE: Test compressor operation to see if the compressor was running. Compressor was running. No voltage from the main control board to the evaporator fan motor . Cause of failure found main control board shorted at the output line voltage to the fan CORRECTION: Replaced main control board and tested. Operation now normal.


Joseph J.

Joseph J. Job Checkin

CONCERN: Customer reports that the dishwasher is not working. DIAGNOSTIC AND CAUSE: Inspected for proper output voltage from wall outlet to dishwasher, output voltage normal at the time of inspection. Inspected for proper input voltage from junction box to control board, voltage input to control board normal at time of inspection. Inspected output voltage from dishwasher control board to dishwasher pump and motor assembly, output voltage to pump and motor assembly normal at the time of inspection. Found dishwasher pump and motor failed. CORRECTION: Replaced dishwasher pump and motor assembly and tested, operation now normal. No leaks upon completion.