Response from Affordable Appliance Repair:

We were in the city of Sun City West working on a GE refrigerator that was not working. We found the main control board had failed and after replacing it operation was normal.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Really professional

Both men were knowledgeable and had my oven problem solved quickly. They were very polite and friendly too.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for sun city west, az

Christopher M.

Christopher M. Job Checkin

CONCERN: Customer reports refrigerator is leaking water. DIAGNOSTIC AND CAUSE: Inspected water supply line for leaks, no leaks at the refrigerator water supply line. Inspected internal water refrigerator water lines for leaks, internal refrigerator water line are normal at the time of inspection. Inspected refrigerator defrost drain line for water leaks, found the source of the leak coming from the refrigerator defrost drain. Removed freezer panel to inspect for clogged drain line. Found the defrost drain restricted with ice and debris. CORRECTION: Cleared the refrigerator defrost drain of ice and debris, operation now normal.


Carlos V.

Carlos V. Job Checkin

CONCERN: Customer reports Refrigerator is not cooling properly. DIAGNOSTIC AND CAUSE: Test compressor operation to see if the compressor was running. Compressor was not running. Tested for voltage from adaptive defrost control board to compressor. No voltage from the main control board to the compressor. Cause of failure found ADC main control board shorted at the output line voltage to the compressor. CORRECTION: Replaced ADC main control board and tested. Operation now normal.


Carlos V.

Carlos V. Job Checkin

CONCERN: Customer reports oven door glass is cracked. CORRECTION: Replaced oven door glass and tested, operation now normal.


Carlos V.

Carlos V. Job Checkin

CONCERN: Customer reports Frigidaire refrigerator ice maker defrosting . Model LGUB2642LF9 CAUSE: Found back panel and evaporator coils covered in frost. Tested the refrigerator defrost bi-metal thermostat for continuity, refrigerator defrost bi-metal continuity failed test. Refrigerator defrost bi-metal has electrical short. CORRECTION: Defrosted refrigerator evaporator coils and replaced defrost bi-metal thermostat. Operation now normal.


Christopher M.

Christopher M. Job Checkin

CONCERN: Customer reports ice maker is not making ice. DIAGNOSTIC AND CAUSE: Inspected water supply lines for leaks, no leaks from supply lines at the time of inspection. Inspected freezer for proper temperature output, temperature output in freezer normal at the time of inspection. Inspected for proper voltage to the ice maker, voltage to ice maker is normal at the time of inspection.Found voltage to the Ice maker normal however ice maker will not call for water from the refrigerator water valve. Found the ice maker failed. CORRECTION: Replaced ice maker and tested. Operation now normal


Carlos V.

Carlos V. Job Checkin

CONCERN: Customer reports Oven is not heating. CAUSE: Tested wall receptacle for proper voltage, line voltage at wall receptacle is normal. Inspected oven cord and terminal block for wear or electrical shorts. No signs of electrical short at power cord or oven terminal block. Inspected oven bake element terminal and found Oven bake element terminal failure. CORRECTION: Replaced oven bake element and tested. Operation now normal.


Carlos V.

Carlos V. Job Checkin

CONCERN: Customer reports ice maker is not making ice. DIAGNOSTIC AND CAUSE: Inspected water supply lines for leaks, no leaks from supply lines at the time of inspection. Inspected freezer for proper temperature output, temperature output in freezer normal at the time of inspection. Inspected for proper voltage to the ice maker, voltage to ice maker is normal at the time of inspection.Found voltage to the Ice maker normal however ice maker will not call for water from the refrigerator water valve. Found the ice maker failed. CORRECTION: Replaced ice maker and tested. Operation now normal


Carlos V.

Carlos V. Job Checkin

CONCERN: Washer is not draining or spinning DIAGNOSTIC AND CAUSE: Inspected washer for proper output voltage from washer control to the washer motor, voltage output is normal at the time of testing. Inspected washer pump, Found washer pump failure. CORRECTION: Replaced washer pump and tested. Operation now normal.


Carlos V.

Carlos V. Job Checkin

CONCERN: Customer reports dishwasher is not working properly. DIAGNOSTIC AND CAUSE: Tested the dishwasher for proper voltage to the dishwasher terminal junction box. Voltage to junction box is normal. Tested voltage from the junction box to the main control board, voltage test normal. Tested voltage from the dishwasher main control board out to water valve and dishwasher float. Found no power going through the dishwasher main control board. CORRECTION: Push all plugs to control board and tested, operation now normal.


Carlos V.

Carlos V. Job Checkin

CONCERN: Customer reports dishwasher is not working properly. DIAGNOSTIC AND CAUSE: Tested the dishwasher for proper voltage to the dishwasher terminal junction box. Voltage to junction box is normal. Tested voltage from the junction box to the main control board, voltage test normal. Tested voltage from the dishwasher main control board out to water valve and dishwasher float. Found no power going through the dishwasher main control board. CORRECTION: Replaced dishwasher main control board and tested, operation now normal.


Carlos V.

Carlos V. Job Checkin

CONCERN: Customer reports ice maker is not making ice. DIAGNOSTIC AND CAUSE: Inspected water supply lines for leaks, no leaks from supply lines at the time of inspection. Inspected freezer for proper temperature output, temperature output in freezer normal at the time of inspection. Inspected for proper voltage to the ice maker, voltage to ice maker is normal at the time of inspection.Found voltage to the Ice maker normal however ice maker will not call for water from the refrigerator water valve. Found the ice maker failed. CORRECTION: Replaced ice maker and tested. Operation now normal CAUSE: Found refrigerator water filter. CORRECTION: Replaced refrigerator water filter and tested for leaks. Operation now normal.


Christopher M.

Christopher M. Job Checkin

CONCERN: Customer reports refrigerator is leaking water onto floor. CAUSE: Technician inspected water supply line from wall to refrigerator water valve. No leaks at supply hose. Inspected water valve for leaks, no leaks at water valve, inspected refrigerator micro tubing, found micro tubing failure. CORRECTION: Replaced and repaired refrigerator micro tubing and check for further leaks. NO LEAKS UPON COMPLETION.


Carlos V.

Carlos V. Job Checkin

CONCERN: Customer reports Whirlpool Refrigerator is not cooling properly. Model GB2FHDXWQ02 DIAGNOSTIC AND CAUSE: Test compressor operation to see if the compressor was running. Compressor was not running. Tested for voltage from adaptive defrost control board to compressor. No voltage from the main control board to the compressor. Cause of failure found ADC main control board shorted at the output line voltage to the compressor. CORRECTION: Replaced ADC main control board and tested. Operation now normal. NRH Johnson/128th ave In Sun City West Arizona


Carlos V.

Carlos V. Job Checkin

CONCERN: Customer reports Frigidaire ice maker is not making ice. Model FRS6R5ESBF DIAGNOSTIC AND CAUSE: Inspected water supply lines for leaks, no leaks from supply lines at the time of inspection. Inspected freezer for proper temperature output, temperature output in freezer normal at the time of inspection. Inspected for proper voltage to the ice maker, voltage to ice maker is normal at the time of inspection.Found voltage to the Ice maker normal however ice maker will not call for water from the refrigerator water valve. Found the ice maker failed. CORRECTION: Replaced ice maker and tested. Operation now normal Beardsley/stardust In Sun City West Arizona


Carlos V.

Carlos V. Job Checkin

CONCERN: Customer reports that the Kenmore ice maker is not functioning properly. Model 106.51564104 DIAGNOSTIC AND CAUSE: Tested output power from control to ice maker, power output is normal. Tested water supply to refrigerator, water supply to refrigerator is normal. Tested ice maker thermostat for continuity, thermostat continuity is normal. Tested ice maker optics, emitter and receiver boards are not communicating. Cause failed ice maker emitter and receiver boards failed. CORRECTION: Replaced ice maker emitter and receiver board and tested, operation is now normal. W10757851