18341 E El Buho Pequeno
Gold Canyon, AZ 85118
602-283-2507

Local Reviews
for surprise, az

Rated 5.0 out of 5 stars based on 6 customer reviews

Carlos was great

  • Overall Experience
  • Quality
  • Price
  • Convenience

Annual Service for Washer & Dryer

For a few years, I have used Affordable Appliance for routine service and repairs...always request Carlos, who is calm, talented, professional. A couple of suggestions: Please park vehicles on the street parallel to sidewalk to avoid any wheel marks/oil drops on driveway; was surprised that routine cleaning was $70 for washer and $70 for dryer. I had understood that this routine service call was to be $75. There were no repairs, just a half hour of cleaning.

  • Overall Experience
  • Quality
  • Price
  • Convenience

wonderful service

Carlos was extremely courteous, kind,and explained everything to me. He showed me that my garbage disposer was cracked and leaking slowly. I called your company because it froze up after being away since March 23rd. Carlos replaced it with a new unit, and made sure all fittings were secure.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Honest, Dependable Service!

We were quite pleased with the service we received! We appreciate that someone answered the call right away and had a service person call us back the same day so we could explain the problems we were having. The next day Chris came out to our home - earlier than expected - and repaired our washer after immediately diagnosing the problem. I appreciate that he took a picture of what was causing the washer to not work so I could see it for myself and send it to my husband. We're very happy with the service fee amount and their honesty about what was wrong with the washer. Thanks!!

  • Overall Experience
  • Quality
  • Price
  • Convenience

On time, clean and efficient

  • Overall Experience
  • Quality
  • Price
  • Convenience

Both Carlos and Evan arrived when they said they would, both extremely courteous and went about fixing the problem. I would highly recommend both of

I will continue to use this company and spread the word to my neighbors if they are in need of such services.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for surprise, az

Christopher M.

Christopher M. Job Checkin

CONCERN: Customer reports Garbage disposal is not working. CAUSE: Garbage disposal breaker tripped. CORRECTION: RE-Set Garbage disposal breaker and tested, operation now normal.


Donald D.

Donald D. Job Checkin

CONCERN: Customer reports dishwasher is not draining. CAUSE: Garbage disposal plug not removed. CORRECTION: Tested dishwasher pump for proper voltage and inspected for restrictions. Found restriction at garbage disposal plug, removed plug and tested. Operation now normal.


Carlos V.

Carlos V. Job Checkin

CONCERN: Customer reports microwave is not working properly. CAUSE: Tested Microwave door switches for continuity, found microwave interlock door switches have electrical short and failed. CORRECTION: Replace microwave interlock door switches and tested. Operation now normal. CONCERN: Customer reports dryer is making a loud noise. CAUSE: Found dryer drum bearing failed. CORRECTION: Replaced and tested. Operation now normal.


Carlos V.

Carlos V. Job Checkin

CONCERN: Customer reports washer is not turning on CAUSE: Found washer no power to control board CORRECTION: Reset power supply (noise reduce control board) and tested, operation now normal.


Carlos V.

Carlos V. Job Checkin

CONCERN: Customer reports washer is fault OE CAUSE: Found washer drive shaft dirty CORRECTION: Remove tub and clean out drive shaft and tested, operation now normal.


Christopher M.

Christopher M. Job Checkin

CONCERN: Customer reports washer water inlet is not working properly. CAUSE: Found washer water valve failed. CORRECTION: Replaced washer water valve and tested. Operation now normal. NOTE: After repairs were completed inspected for leaks, no leaks at time of completion


Christopher M.

Christopher M. Job Checkin

CONCERN: Dryer takes too long to dry clothes, dryer does get hot though. DIAGNOSTIC AND CAUSE: Tested dryer for proper heater element operation. Heater operation is good. Inspected dryer air flow at the duct flume, air flow is normal at this time, no signs of flow restriction. Cause, Wall vent clogged with lint. CORRECTION: Performed dryer vent cleaning, tested for restrictions, operation now normal


Carlos V.

Carlos V. Job Checkin

CONCERN: Customer reports WHIRLPOOL washer is not agitating. CAUSE: Washer agitator gears stripped. CORRECTION: Replaced agitator gears, screw and tested, operation now normal.


Christopher M.

Christopher M. Job Checkin

CONCERN: Customer reports MAYTAG dryer is not heating Mod# SDG3606AWW CAUSE: Found dryer glow ignitor failed. CORRECTION: Replaced dryer glow ignitor and tested. Operation now normal.


Carlos V.

Carlos V. Job Checkin

CONCERN: Customer reports that the Maytag washer is not draining. DIAGNOSTIC AND CAUSE: Inspected wall outlet for proper voltage to washer, voltage output from wall outlet normal at the time of inspection. Inspected voltage output from control to washer drain pump, voltage to drain pump normal at the time of inspection. Found washer pump impeller was trying to turn however the technician found washer drain pump clogged with debris. CORRECTION: Removed drain pump to clear debris and re-installed, check for leaks and tested, Operation now normal.


Carlos V.

Carlos V. Job Checkin

CONCERN: Customer reports refrigerator is not getting cold on refrigerator side. DIAGNOSTIC AND CAUSE: Inspected compressor operation, evaporator fan and condenser fan operation, all normal. Found frost build up on evaporator coils. Tested defrost heater for continuity, Found defrost heater and limiter shorted. CORRECTION: Replaced defrost heater and limiter. Tested operation, all normal upon completion.


Carlos V.

Carlos V. Job Checkin

CONCERN: Customer reports Refrigerator is not cooling properly. DIAGNOSTIC AND CAUSE: Test compressor operation to see if the compressor was running. Compressor was not running. Tested for voltage from adaptive defrost control board to compressor. No voltage from the main control board to the compressor. Cause of failure found ADC main control board shorted at the output line voltage to the compressor. CORRECTION: Replaced ADC main control board and tested. Operation now normal.


Carlos V.

Carlos V. Job Checkin

CONCERN: Customer reports washer making a loud noise. CAUSE: Found washer rear tub bearings failed. CORRECTION: Replace both rear tub bearings and seal. Operation is now normal


Carlos V.

Carlos V. Job Checkin

CONCERN: Customer reports refrigerator is leaking water onto floor. DIAGNOSTIC AND CAUSE: Inspected water supply line to refrigerator for leaks, no leaks found at this time. Inspected water valve for leaks, found water valve failure. CORRECTION: Replaced water valve and tested. Operation now normal.


Carlos V.

Carlos V. Job Checkin

CONCERN: Customer reports GE Refrigerator/freezer is not cooling properly. Model ZIRS36NMHLH CAUSE: Found refrigeration system low on freon. CORRECTION: Recharged system and tested. Operation now normal. Note: NO GUARANTEE ON RECHARGING SYSTEM. Since a refrigerator that is low on freon has a known leak we cannot guarantee performance of the unit after freon has been refilled. When a welded unit is low on freon it has leaked out, however we cannot determine the rate at which a leak is. Customer has acknowledged that this is a temporary fix only and is not to be considered a long lasting repair.Thurs 1-3 GE Ref not cool enough Pinnacle/219th ave Near CIMARRON GOLF COURSE in Surprise AZ Model ZIRS36NMHLH evap fan motor WR60X10139, bi metal WR50X10003, heater WR49X10016, condenser fan motor WR60X10348

CONCERN: Customer reports GE Refrigerator/freezer is not cooling properly. Model ZIRS36NMHLH CAUSE: Found refrigeration system low on freon. CORRECTION: Recharged system and tested. Operation now normal. 
Note: NO GUARANTEE ON RECHARGING SYSTEM. Since a refrigerator that is low on freon has a known leak we cannot guarantee performance of the unit after freon has been refilled. When a welded unit is low on freon it has leaked out, however we cannot determine the rate at which a leak is. Customer has acknowledged that this is a temporary fix only and is not to be considered a long lasting repair.Thurs 1-3 GE Ref not cool enough Pinnacle/219th ave Near CIMARRON GOLF COURSE in Surprise AZ 
Model ZIRS36NMHLH evap fan motor WR60X10139, bi metal WR50X10003, heater WR49X10016, condenser fan motor WR60X10348