18341 E El Buho Pequeno
Gold Canyon, AZ 85118
602-283-2507

Local Reviews
for tempe, az

Rated 4.9 out of 5 stars based on 13 customer reviews

Very helpful!

The process was so easy and affordable. David was incredibly knowledgeable and helpful.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Awesome service - awesome price.

I was so pleased with AARs fast follow up & service to my dryer. Cameron came out and went right to work - letting me watch - and explained things as he went. It was very clear was the issue was, what he had to do to fix it & he got it taken care of. I’m so happy to have my dryer working again!!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Awesome Service


Response from Affordable Appliance Repair:

Thank you so much for taking the time to let us know how we did.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service

Serviceman was knowledgeable and friendly

  • Overall Experience
  • Quality
  • Price
  • Convenience

  • Overall Experience
  • Quality
  • Price
  • Convenience

Five stars! All categories.

Very pleased with everything. Professionalism, timeliness of repair, questions answered, and the cost.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service

  • Overall Experience
  • Quality
  • Price
  • Convenience

Doug went over and above.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent and Fast!

Mike from AAR fixed my refrigerator/freezer yesterday and couldn’t have been more courteous and friendly. Service was prompt, even faster than expected, and he showed and talked to me about the issues. Today it’s running perfectly! Thank you!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service!

David was so quick to know exactly what was wrong with our dryer. He was knowledgeable and even showed me what piece we needed to get and where to get it from. Great service and great team!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for tempe, az

Daren O.

Daren O. Job Checkin

CONCERN: Customer reports dryer is making a loud noise. CAUSE: Found dryer idler pulley failed. CORRECTION: Replaced dryer idler pulley and tested, operation now normal.


Donald D.

Donald D. Job Checkin

CONCERN: Customer reports washer is not spinning. CAUSE: Found washer splutch assembly failed. CORRECTION: Replaced washer splutch assembly and tested, operation is now normally.


Rene  G.

Rene G. Job Checkin

CONCERN: Customer reports dishwasher is not draining properly. DIAGNOSTIC AND CAUSE: Inspected wall outlet for proper voltage to dishwasher, voltage normal at the time of inspection. Inspected voltage to main control input, dishwasher main control input voltage normal at the time of inspection. Inspected main control output voltage to the dishwasher drain pump, main control output voltage, normal at the time of inspection. Inspected voltage to drain pump and found proper operating voltage to Dishwasher drain pump, dishwasher drain pump impeller still not working. Dishwasher drain pump failed. CORRECTION: Replaced dishwasher drain pump and tested, operation now normal. CONCERN: Customer reports washer water inlet is not working properly. CAUSE: Found washer water valve failed. CORRECTION: Replaced washer water valve and tested. Operation now normal. NOTE: After repairs were completed inspected for leaks, no leaks at time of completion


David R.

David R. Job Checkin

CONCERN: Customer reports refrigerator is not cooling properly. CAUSE: Found refrigeration system low on freon. CORRECTION: Recharged system and tested. Operation now normal. Note: NO GUARANTEE ON RECHARGING SYSTEM. Since a refrigerator that is low on freon has a known leak we cannot guarantee performance of the unit after freon has been refilled. When a welded unit is low on freon it has leaked out, however we cannot determine the rate at which a leak is. Customer has acknowledged that this is a temporary fix only and is not to be considered a long lasting repair.


Daren O.

Daren O. Job Checkin

CONCERN: Customer reports Refrigerator is not cooling properly. DIAGNOSTIC AND CAUSE: Test compressor operation to see if the compressor was running. Compressor was running. Cause of failure found ADC main control board shorted at the output line voltage to the defrost thermostat and issue with main pcb.CORRECTION: Replaced ADC main control board and defrost thermostat.cleared evap of frost buildup Operation now normal.


Daren O.

Daren O. Job Checkin

CONCERN: Customer reports dishwasher is leaking. DIAGNOSTIC AND CAUSE: Inspected water supply lines to the dishwasher, supply lines are normal at the time of inspection. Inspected dishwasher water valve for leaks, dishwasher water valve is normal. Filled dishwasher with water to inspect for leaks, found dishwasher door gasket failed. CORRECTION: Replaced door gasket and tested for leaks. Operation now normal.


Donald D.

Donald D. Job Checkin

CONCERN: Customer reports dryer is not heating. CAUSE: Inspected dryer wall receptacle for proper voltage to the dryer, voltage to the dryer is normal at the time of inspection. Inspected dryer terminal block and cord for visible shorts, no shorts found at terminal block or cord at the time of inspection. Inspected dryer heater continuity on the heater element, heating element tested good at the time of inspection, Tested thermal safety for continuity, no continuity present, Found dryer thermal safety shorted out. CORRECTION: Replaced dryer thermal safety and tested. Operation now normal.


Daren O.

Daren O. Job Checkin

CONCERN: Customer reports dishwasher is not working properly. DIAGNOSTIC AND CAUSE: Tested the dishwasher for proper voltage to the dishwasher terminal junction box. Voltage to junction box is normal. Tested voltage from the junction box to the main control board, voltage test normal. Tested voltage from the dishwasher main control board out to water valve and dishwasher float. Found no power going through the dishwasher main control board. CORRECTION: Replaced dishwasher main control board and tested, operation now normal.


David R.

David R. Job Checkin

CONCERN: Customer reports that the Refrigerator is not getting cold. CAUSE: Inspected wall voltage for proper output, voltage output is normal. Inspected compressor for proper voltage, voltage to compressor is normal. Inspected compressor starter for proper continuity, no continuity at the compressor starter. Tested compressor windings for electrical shorts, no shorts at compressor windings. CORRECTION: Replaced compressor starter and tested. Operation now normal.


David R.

David R. Job Checkin

CONCERN: Customer reports that both ovens are not heating properly. CORRECTION: Replaced oven temperature sensors and tested oven operation. Operation now normal upon completion of repair.


Doug D.

Doug D. Job Checkin

CONCERN: Customer reports refrigerator is not as cold as it should be. DIAGNOSTIC AND CAUSE: Inspected wall outlet for proper voltage output, voltage output normal at the time of inspection. Inspected for voltage input at the compressor, compressor voltage input normal at the time of inspection. NOTE: Compressor was running and cooling unit down. Inspected voltage input at the condenser fan motor, input voltage was normal at the time of inspection. Found condenser fan motor Locked up and not running. CORRECTION: Replaced condenser fan motor and tested. Operation now normal. CONCERN: Customer reports refrigerator seems to run all the time. CAUSE: Found condenser coils clogged with debris. CORRECTION: Clean condenser coils and tested, operation now normal.


Spencer B.

Spencer B. Job Checkin

CONCERN: Customer reports SAMSUNG dryer is making a loud noise. CAUSE: Found dryer idler pulley failed. and right rear roller wheel CORRECTION: Replaced dryer idler pulley and roller wheel tested, operation now normal.


Steve R.

Steve R. Job Checkin

CONCERN: Customer reports LG Washer is not draining or spinning MODEL WM2075CCW DIAGNOSTIC AND CAUSE: Inspected washer for proper output voltage from washer control to the washer motor, voltage output is normal at the time of testing. Inspected washer pump, Found washer pump failure. CORRECTION: Replaced washer pump and tested. Operation now normal.


David R.

David R. Job Checkin

CONCERN: Customer reports GE Refrigerator is not cooling properly at times. DIAGNOSTIC AND CAUSE: Test compressor operation to see if the compressor was running. Compressor was running. Tested for voltage from adaptive defrost control board to compressor. Voltage from the main control board to the compressor normal at this time. Cause of failure most likely ADC main control board relay sticking. CORRECTION: Replaced ADC main control board and tested. Operation now normal.


David R.

David R. Job Checkin

CONCERN: Customer reports GE refrigerator is not as cold as it should be. Model DLT18ICSVRBS DIAGNOSTIC AND CAUSE: Inspected wall outlet for proper voltage output, voltage output normal at the time of inspection. Inspected for voltage input at the compressor, compressor voltage input normal at the time of inspection. NOTE: Compressor was running and cooling unit down. Inspected voltage input at the condenser fan motor, input voltage was normal at the time of inspection. Found condenser fan motor Locked up and not running. CORRECTION: Replaced condenser fan motor and tested. Operation now normal.