18341 E El Buho Pequeno
Gold Canyon, AZ 85118
602-283-2507

Local Reviews
for tempe, az

Rated 4.9 out of 5 stars based on 15 customer reviews

Great

Joey was great. I will use you again

  • Overall Experience
  • Quality
  • Price
  • Convenience

well done

  • Overall Experience
  • Quality
  • Price
  • Convenience

Very helpful!

The process was so easy and affordable. David was incredibly knowledgeable and helpful.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Awesome service - awesome price.

I was so pleased with AARs fast follow up & service to my dryer. Cameron came out and went right to work - letting me watch - and explained things as he went. It was very clear was the issue was, what he had to do to fix it & he got it taken care of. I’m so happy to have my dryer working again!!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Awesome Service


Response from Affordable Appliance Repair:

Thank you so much for taking the time to let us know how we did.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service

Serviceman was knowledgeable and friendly

  • Overall Experience
  • Quality
  • Price
  • Convenience

  • Overall Experience
  • Quality
  • Price
  • Convenience

Five stars! All categories.

Very pleased with everything. Professionalism, timeliness of repair, questions answered, and the cost.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service

  • Overall Experience
  • Quality
  • Price
  • Convenience

Doug went over and above.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for tempe, az

Donald D.

Donald D. Job Checkin

CONCERN: Customer reports ice maker is not making ice. DIAGNOSTIC AND CAUSE: Inspected water supply lines for leaks, no leaks from supply lines at the time of inspection. Inspected freezer for proper temperature output, temperature output in freezer normal at the time of inspection. Inspected for proper voltage to the ice maker, voltage to ice maker is normal at the time of inspection.Found voltage to the Ice maker normal however ice maker will not call for water from the refrigerator water valve. Found the ice maker failed. CORRECTION: Replaced ice maker and tested. Operation now normal. No leaks upon completion.


Donald D.

Donald D. Job Checkin

CONCERN: Customer reports washer making a loud noise. CAUSE: Found washer rear tub bearings failed. CORRECTION: Replace both rear tub bearings and seal. Operation is now normal. No leaks upon completion. CONCERN: Dryer takes too long to dry clothes, dryer does get hot though. DIAGNOSTIC AND CAUSE: Tested dryer for proper heater element operation. Heater operation is normal. Inspected heater thermostat operation for short cycling condition, thermostat is short cycling. Inspected dryer air flow at the duct flume, air flow is normal at this time, no signs of flow restriction. Cause, Wall vent clogged with lint. CORRECTION: Performed dryer vent cleaning, tested for restrictions, operation now normal


Daren O.

Daren O. Job Checkin

CONCERN: Customer reports refrigerator door is not sealing properly. Seals worn on upper french doors. Lower freezer door seal check ok at this time. CAUSE: Found refrigerator door gasket failed. CORRECTION: Replaced door gasket and tested, operation now normal.


Daren O.

Daren O. Job Checkin

CONCERN: Customer reports refrigerator is not working properly. CAUSE: Found refrigerator defrost timer failed. CORRECTION: installed new defrost timer board and bi metal thermostat. Test unit. Test ok.


Cameron D.

Cameron D. Job Checkin

CONCERN: Customer reports Oven door is misaligned and will not function correctly. CAUSE: Found right door hinge failed. CORRECTION: Replaced door hinge and tested. Operation now normal.


Cameron D.

Cameron D. Job Checkin

CONCERN: Customer reports that the washer is not draining. DIAGNOSTIC AND CAUSE: Inspected wall outlet for proper voltage to washer, voltage output from wall outlet normal at the time of inspection. Inspected voltage output from control to washer drain pump, voltage to drain pump normal at the time of inspection. Found washer pump impeller was trying to turn however the technician found washer drain pump clogged with debris. CORRECTION: Removed drain pump to clear debris and re-installed, check for leaks and tested, Operation now normal. No leaks upon completion.


Joseph J.

Joseph J. Job Checkin

CONCERN: Customer reports dishwasher is not draining. CAUSE: Found debris stuck in drain pump impeller restricting operation. CORRECTION: Removed drain pump and cleared debris. Tested unit operation is now normal. No leaks upon completion.


Daren O.

Daren O. Job Checkin

CONCERN: Customer reports ice maker is not making ice. DIAGNOSTIC AND CAUSE: Inspected water supply lines for leaks, no leaks from supply lines at the time of inspection. Inspected freezer for proper temperature output, temperature output in freezer normal at the time of inspection. Inspected for proper voltage to the ice maker, voltage to ice maker is normal at the time of inspection.Found voltage to the Ice maker normal however ice maker will not call for water from the refrigerator water valve. Found the ice maker failed. CORRECTION: Replaced ice maker and tested. Operation now normal


Daren O.

Daren O. Job Checkin

CONCERN: Customer reports washer is going out of balance, not working. CAUSE: Found washer suspension rods weak, suspension teather broke on tub ring. Lid switch wires broken from being out of balance. CORRECTION: Replaced suspension rods, top ring and repaired lid switch, tested, operation now normal.


Cameron D.

Cameron D. Job Checkin

CONCERN: Customer reports refrigerator not cooling correctly. CAUSE: Found condenser coils clogged with debris. CORRECTION: Clean condenser coils and tested, operation now normal.


David R.

David R. Job Checkin

CONCERN: Customer reports freezer is not cold enough. CAUSE: Found condenser coils clogged with debris. CORRECTION: Clean condenser coils and tested, operation now normal.


Cameron D.

Cameron D. Job Checkin

CONCERN: Customer reports that the Refrigerator is not getting cold in either compartment. CAUSE: Inspected wall voltage for proper output, voltage output is normal. Inspected compressor for proper voltage, voltage to compressor is normal. Inspected compressor starter for proper continuity, no continuity at the compressor starter. Tested compressor windings for electrical shorts, no shorts at compressor windings. CORRECTION: Replaced compressor starter and tested. Operation now normal.


Steve R.

Steve R. Job Checkin

CONCERN: Customer reports dryer will not start. CAUSE: Found dryer start switch failed. CORRECTION: Replaced dryer start switch and tested, operation now normal.


Donald D.

Donald D. Job Checkin

CONCERN: Customer reports ice maker is not making ice. DIAGNOSTIC AND CAUSE: Inspected water supply lines for leaks, no leaks from supply lines at the time of inspection. Inspected freezer for proper temperature output, temperature output in freezer normal at the time of inspection. Inspected for proper voltage to the ice maker, voltage to ice maker is normal at the time of inspection.Found voltage to the Ice maker normal however ice maker will not call for water from the refrigerator water valve. Found the ice maker failed. CORRECTION: Replaced ice maker and tested. Operation now normal. No leaks upon completion.


Daren O.

Daren O. Job Checkin

CONCERN: Customer reports that the washer is not draining. DIAGNOSTIC AND CAUSE: Inspected wall outlet for proper voltage to washer, voltage output from wall outlet normal at the time of inspection. Inspected voltage output from control to washer drain pump, voltage to drain pump normal at the time of inspection. Found washer pump impeller was trying to turn however the technician found washer drain pump clogged with debris. CORRECTION: Removed drain pump to clear debris and re-installed, check for leaks and tested No leaks upon completion. Operation now normal. NOTE: Tenant did clear pump filter of debris. Debris was in pump impeller not allowing pump to run