18341 E El Buho Pequeno
Gold Canyon, AZ 85118
602-283-2507

Local Reviews
for tempe, az

Rated 4.9 out of 5 stars based on 11 customer reviews

Awesome Service


Response from Affordable Appliance Repair:

Thank you so much for taking the time to let us know how we did.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service

Serviceman was knowledgeable and friendly

  • Overall Experience
  • Quality
  • Price
  • Convenience

  • Overall Experience
  • Quality
  • Price
  • Convenience

Five stars! All categories.

Very pleased with everything. Professionalism, timeliness of repair, questions answered, and the cost.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service

  • Overall Experience
  • Quality
  • Price
  • Convenience

Doug went over and above.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent and Fast!

Mike from AAR fixed my refrigerator/freezer yesterday and couldn’t have been more courteous and friendly. Service was prompt, even faster than expected, and he showed and talked to me about the issues. Today it’s running perfectly! Thank you!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service!

David was so quick to know exactly what was wrong with our dryer. He was knowledgeable and even showed me what piece we needed to get and where to get it from. Great service and great team!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service

Have been using this company for 15 years! Always excellent 😃

  • Overall Experience
  • Quality
  • Price
  • Convenience

fantastic

Spencer was quick, polite and professional. And he called to say he would be early for the appointment! Fantastic service.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for tempe, az

David R.

David R. Job Checkin

CONCERN: Customer reports that both ovens are not heating properly. CORRECTION: Replaced oven temperature sensors and tested oven operation. Operation now normal upon completion of repair.


Doug D.

Doug D. Job Checkin

CONCERN: Customer reports refrigerator is not as cold as it should be. DIAGNOSTIC AND CAUSE: Inspected wall outlet for proper voltage output, voltage output normal at the time of inspection. Inspected for voltage input at the compressor, compressor voltage input normal at the time of inspection. NOTE: Compressor was running and cooling unit down. Inspected voltage input at the condenser fan motor, input voltage was normal at the time of inspection. Found condenser fan motor Locked up and not running. CORRECTION: Replaced condenser fan motor and tested. Operation now normal. CONCERN: Customer reports refrigerator seems to run all the time. CAUSE: Found condenser coils clogged with debris. CORRECTION: Clean condenser coils and tested, operation now normal.


Spencer B.

Spencer B. Job Checkin

CONCERN: Customer reports SAMSUNG dryer is making a loud noise. CAUSE: Found dryer idler pulley failed. and right rear roller wheel CORRECTION: Replaced dryer idler pulley and roller wheel tested, operation now normal.


Steve R.

Steve R. Job Checkin

CONCERN: Customer reports LG Washer is not draining or spinning MODEL WM2075CCW DIAGNOSTIC AND CAUSE: Inspected washer for proper output voltage from washer control to the washer motor, voltage output is normal at the time of testing. Inspected washer pump, Found washer pump failure. CORRECTION: Replaced washer pump and tested. Operation now normal.


David R.

David R. Job Checkin

CONCERN: Customer reports GE Refrigerator is not cooling properly at times. DIAGNOSTIC AND CAUSE: Test compressor operation to see if the compressor was running. Compressor was running. Tested for voltage from adaptive defrost control board to compressor. Voltage from the main control board to the compressor normal at this time. Cause of failure most likely ADC main control board relay sticking. CORRECTION: Replaced ADC main control board and tested. Operation now normal.


David R.

David R. Job Checkin

CONCERN: Customer reports GE refrigerator is not as cold as it should be. Model DLT18ICSVRBS DIAGNOSTIC AND CAUSE: Inspected wall outlet for proper voltage output, voltage output normal at the time of inspection. Inspected for voltage input at the compressor, compressor voltage input normal at the time of inspection. NOTE: Compressor was running and cooling unit down. Inspected voltage input at the condenser fan motor, input voltage was normal at the time of inspection. Found condenser fan motor Locked up and not running. CORRECTION: Replaced condenser fan motor and tested. Operation now normal.


Donald D.

Donald D. Job Checkin

CONCERN: Customer reports ice maker is not making ice. DIAGNOSTIC AND CAUSE: Inspected water supply lines for leaks, no leaks from supply lines at the time of inspection. Inspected freezer for proper temperature output, temperature output in freezer normal at the time of inspection. Inspected for proper voltage to the ice maker, voltage to ice maker is normal at the time of inspection.Found voltage to the Ice maker normal however ice maker will not call for water from the refrigerator water valve. Found the ice maker failed. CORRECTION: Replaced ice maker and tested. Operation now normal


Carlos V.

Carlos V. Job Checkin


David R.

David R. Job Checkin

CONCERN: Customer reports refrigerator is not as cold as it should be. DIAGNOSTIC AND CAUSE: Inspected wall outlet for proper voltage output, voltage output normal at the time of inspection. Inspected for voltage input at the compressor, compressor voltage input normal at the time of inspection. NOTE: Compressor was running and cooling unit down. Inspected voltage input at the condenser fan motor, input voltage was normal at the time of inspection. Found condenser fan motor Locked up and not running. CORRECTION: Replaced condenser fan motor and tested. Operation now normal.


David R.

David R. Job Checkin

CAUSE: Found door hinges failed. CORRECTION: Replaced door hinges and tested. Operation now normal.


Nick H.

Nick H. Job Checkin

CONCERN: Customer reports that the dishwasher is not cleaning the dishes. CAUSE: Dishwasher has soap and scum build up. CORRECTION: Performed dishwasher cabinet clean out, cleaned dishwasher sump and chopper area to remove debris. Cleaned spray arms as best as possible, installed citrus acid solution and ran machine to disinfect and clean spray ports and sump area of mold and mildred residue. Operation now normal.


David R.

David R. Job Checkin

CONCERN: Customer states washer is not working properly. DIAGNOSTIC AND CAUSE: Inspected wall receptacle for proper outlet voltage to washer, wall receptacle voltage is normal at the time of inspection. Inspected washer controls for proper input voltage, voltage normal at time of inspection. Inspected washer interlock continuity, found washer interlock switch failed. CORRECTION: Replaced washer interlock switch and tested on all cycles, operation now normal. CONCERN: Washer door does not close properly. CAUSE: Found door hinge bracket stripped/failed. CORRECTION: R&R door to repair door hinge bracket and tested. Operation now normal.


Michael H.

Michael H. Job Checkin

CONCERN: Customer reports ice maker is not making ice. DIAGNOSTIC AND CAUSE: Inspected water supply lines for leaks, no leaks from supply lines at the time of inspection. Inspected freezer for proper temperature output, temperature output in freezer normal at the time of inspection. Inspected for proper voltage to the ice maker, voltage to ice maker is normal at the time of inspection.Found voltage to the Ice maker normal however ice maker will not call for water from the refrigerator water valve. Found the ice maker failed. CORRECTION: Replaced ice maker and tested. Operation now normal


David R.

David R. Job Checkin

CONCERN: Customer reports refrigerator is not cooling properly. CAUSE: Found refrigeration system low on freon. CORRECTION: Recharged system and tested. Operation now normal. Note: NO GUARANTEE ON RECHARGING SYSTEM. Since a refrigerator that is low on freon has a known leak we cannot guarantee performance of the unit after freon has been refilled. When a welded unit is low on freon it has leaked out, however we cannot determine the rate at which a leak is. Customer has acknowledged that this is a temporary fix only and is not to be considered a long lasting repair.


Michael H.

Michael H. Job Checkin

CONCERN: Customer reports ice maker is not making ice. DIAGNOSTIC AND CAUSE: Inspected water supply lines for leaks, no leaks from supply lines at the time of inspection. Inspected freezer for proper temperature output, temperature output in freezer normal at the time of inspection. Inspected for proper voltage to the ice maker, voltage to ice maker is normal at the time of inspection.Found voltage to the Ice maker normal however ice maker will not call for water from the refrigerator water valve. Found the ice maker failed. CORRECTION: Replaced ice maker and tested. Operation now normal