18341 E El Buho Pequeno
Gold Canyon, AZ 85118
602-283-2507

Local Reviews
for tempe, az

Rated 4.9 out of 5 stars based on 15 customer reviews

Great

Joey was great. I will use you again

  • Overall Experience
  • Quality
  • Price
  • Convenience

well done

  • Overall Experience
  • Quality
  • Price
  • Convenience

Very helpful!

The process was so easy and affordable. David was incredibly knowledgeable and helpful.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Awesome service - awesome price.

I was so pleased with AARs fast follow up & service to my dryer. Cameron came out and went right to work - letting me watch - and explained things as he went. It was very clear was the issue was, what he had to do to fix it & he got it taken care of. I’m so happy to have my dryer working again!!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Awesome Service


Response from Affordable Appliance Repair:

Thank you so much for taking the time to let us know how we did.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service

Serviceman was knowledgeable and friendly

  • Overall Experience
  • Quality
  • Price
  • Convenience

  • Overall Experience
  • Quality
  • Price
  • Convenience

Five stars! All categories.

Very pleased with everything. Professionalism, timeliness of repair, questions answered, and the cost.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service

  • Overall Experience
  • Quality
  • Price
  • Convenience

Doug went over and above.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for tempe, az

Daren O.

Daren O. Job Checkin

CONCERN: Customer reports ice maker is not making ice. DIAGNOSTIC AND CAUSE: Inspected water supply lines for leaks, no leaks from supply lines at the time of inspection. Inspected freezer for proper temperature output, temperature output in freezer normal at the time of inspection. Inspected for proper voltage to the ice maker, voltage to ice maker is normal at the time of inspection.Found voltage to the Ice maker normal however ice maker will not call for water from the refrigerator water valve. Found the ice maker failed. CORRECTION: Replaced ice maker and tested. Operation now normal


Daren O.

Daren O. Job Checkin

CONCERN: Customer reports washer is going out of balance, not working. CAUSE: Found washer suspension rods weak, suspension teather broke on tub ring. Lid switch wires broken from being out of balance. CORRECTION: Replaced suspension rods, top ring and repaired lid switch, tested, operation now normal.


Cameron D.

Cameron D. Job Checkin

CONCERN: Customer reports refrigerator not cooling correctly. CAUSE: Found condenser coils clogged with debris. CORRECTION: Clean condenser coils and tested, operation now normal.


David R.

David R. Job Checkin

CONCERN: Customer reports freezer is not cold enough. CAUSE: Found condenser coils clogged with debris. CORRECTION: Clean condenser coils and tested, operation now normal.


Cameron D.

Cameron D. Job Checkin

CONCERN: Customer reports that the Refrigerator is not getting cold in either compartment. CAUSE: Inspected wall voltage for proper output, voltage output is normal. Inspected compressor for proper voltage, voltage to compressor is normal. Inspected compressor starter for proper continuity, no continuity at the compressor starter. Tested compressor windings for electrical shorts, no shorts at compressor windings. CORRECTION: Replaced compressor starter and tested. Operation now normal.


Steve R.

Steve R. Job Checkin

CONCERN: Customer reports dryer will not start. CAUSE: Found dryer start switch failed. CORRECTION: Replaced dryer start switch and tested, operation now normal.


Donald D.

Donald D. Job Checkin

CONCERN: Customer reports ice maker is not making ice. DIAGNOSTIC AND CAUSE: Inspected water supply lines for leaks, no leaks from supply lines at the time of inspection. Inspected freezer for proper temperature output, temperature output in freezer normal at the time of inspection. Inspected for proper voltage to the ice maker, voltage to ice maker is normal at the time of inspection.Found voltage to the Ice maker normal however ice maker will not call for water from the refrigerator water valve. Found the ice maker failed. CORRECTION: Replaced ice maker and tested. Operation now normal. No leaks upon completion.


Daren O.

Daren O. Job Checkin

CONCERN: Customer reports that the washer is not draining. DIAGNOSTIC AND CAUSE: Inspected wall outlet for proper voltage to washer, voltage output from wall outlet normal at the time of inspection. Inspected voltage output from control to washer drain pump, voltage to drain pump normal at the time of inspection. Found washer pump impeller was trying to turn however the technician found washer drain pump clogged with debris. CORRECTION: Removed drain pump to clear debris and re-installed, check for leaks and tested No leaks upon completion. Operation now normal. NOTE: Tenant did clear pump filter of debris. Debris was in pump impeller not allowing pump to run


David R.

David R. Job Checkin

CONCERN: Customer reports Refrigerator is not cooling properly. DIAGNOSTIC AND CAUSE: Test compressor operation to see if the compressor was running. Compressor was not running. Tested for voltage from adaptive defrost control board to compressor. No voltage from the main control board to the compressor. Cause of failure found ADC main control board shorted at the output line voltage to the compressor. CORRECTION: Replaced ADC main control board and tested. Operation now normal.


Cameron D.

Cameron D. Job Checkin

CONCERN: Customer reports dryer is not heating. DIAGNOSTIC AND CAUSE: Inspected dryer for proper voltage from the wall to the cord terminal block, voltage normal. Inspected voltage from terminal block to dryer control assembly, voltage normal. Inspected continuity on all thermal safety thermostats, all thermal safeties are normal. Inspected continuity at heater element, found dryer heating element failed. CORRECTION: Replaced dryer heating element and tested. Operation now normal.


Daren O.

Daren O. Job Checkin

CONCERN: Customer reports dryer is making a loud noise. CAUSE: Found dryer idler pulley failed. CORRECTION: Replaced dryer idler pulley and tested, operation now normal.


Donald D.

Donald D. Job Checkin

CONCERN: Customer reports washer is not spinning. CAUSE: Found washer splutch assembly failed. CORRECTION: Replaced washer splutch assembly and tested, operation is now normally.


Rene  G.

Rene G. Job Checkin

CONCERN: Customer reports dishwasher is not draining properly. DIAGNOSTIC AND CAUSE: Inspected wall outlet for proper voltage to dishwasher, voltage normal at the time of inspection. Inspected voltage to main control input, dishwasher main control input voltage normal at the time of inspection. Inspected main control output voltage to the dishwasher drain pump, main control output voltage, normal at the time of inspection. Inspected voltage to drain pump and found proper operating voltage to Dishwasher drain pump, dishwasher drain pump impeller still not working. Dishwasher drain pump failed. CORRECTION: Replaced dishwasher drain pump and tested, operation now normal. CONCERN: Customer reports washer water inlet is not working properly. CAUSE: Found washer water valve failed. CORRECTION: Replaced washer water valve and tested. Operation now normal. NOTE: After repairs were completed inspected for leaks, no leaks at time of completion


David R.

David R. Job Checkin

CONCERN: Customer reports refrigerator is not cooling properly. CAUSE: Found refrigeration system low on freon. CORRECTION: Recharged system and tested. Operation now normal. Note: NO GUARANTEE ON RECHARGING SYSTEM. Since a refrigerator that is low on freon has a known leak we cannot guarantee performance of the unit after freon has been refilled. When a welded unit is low on freon it has leaked out, however we cannot determine the rate at which a leak is. Customer has acknowledged that this is a temporary fix only and is not to be considered a long lasting repair.


Daren O.

Daren O. Job Checkin

CONCERN: Customer reports Refrigerator is not cooling properly. DIAGNOSTIC AND CAUSE: Test compressor operation to see if the compressor was running. Compressor was running. Cause of failure found ADC main control board shorted at the output line voltage to the defrost thermostat and issue with main pcb.CORRECTION: Replaced ADC main control board and defrost thermostat.cleared evap of frost buildup Operation now normal.