GOODMAN AIR CONDITIONER CHANGE BLOWER SPEED FROM HIGH TO MEDIUM .Changed blower motor speed to medium .
GOODMAN AIR CONDITIONER GO BY AND CHECK ON CUSTOMERS REPAIRS. Upon arriving found that unit was low on charge. Checked leak on full system and found that the schrader valve on discharge was loose and leaking . Removed all the caps to check for any further leaks and removed condenser fan motor to check condenser . Checked evaporator coil and set . Tightened schrader valves and installed leak lock . Charged unit 2lbs of 410a . Cycled unit and unit is operating properly .
WANTS TO EXTEND DUCT WORK IN THE BASEMENT AND GO UPSTAIRS/CUST IS SAYING 12FT
CORREY REACH IN COOLER MAIN UNIT NOT COOLING needs new compressor and hard start kit
GOODMAN GOODMAN NO HEAT, NOT COMING ON PLACED THE FILTER IN THE UNIT AND UNIT IS WORKING
WANTS TO EXTEND DUCT WORK IN THE BASEMENT AND GO UPSTAIRS/CUST IS SAYING 12FT GAVE CUSTOMER AND ESTATMENT ON WHAT IT WAS GOING TO COST TO REPLACE THE DUCT WORK
WELLS FRYER THE DIAL THAT CONTROLS TEMP IS SPINNING REPLACED THE THERMOSTAT
ADVANTCO VENT HOOD NOT PULLING AIR FOUDN THE FILTER NOT INSTALLED CORRECTLY REINSTALLED
ADVANTCO VENT HOOD NOT COMING ON MOST OF THE TIME REPLACED THE BELT ON THE MOTOR
TRUE REACH IN COOLER 3 DROOR - NOT HOLDING TEMP/UNIT IS OFF BY A COUPLE DEG instaled evaporator motor
RUUD FURNACE KICKING ON AND OFF ADJUSTED THE TSTAT AND UNIT IS WORKING