Kirk L.

Kirk L. Job Checkin

DELFIELD PREP COOLER LEAKING WATER AND NOT COOLING FOUDN UNIT LOW CHARGE AND THE DRAIN LINE WAS CLOGGED ALSO INSTALLED A LEAK LOCK


Kirk L.

Kirk L. Job Checkin

DELFIELD PREP COOLER NOT COOLING FOUND THE UNIT WAS LOW ON CHARGE ADDED FREON AND CLEANED THE DRIAN LINES


Kirk L.

Kirk L. Job Checkin

DELFIELD PREP COOLER SLOWLY DROPPING IN TEMP/SHUT UNIT OF AT 75 DEG FPUND THE EVAPORATOR FROZEN ADJUSTED TEH THEROSTAT


ANTHONY M.

ANTHONY M. Job Checkin

MANITOWOC ICE MACHINE LEAKING APPLIED FOAM TAPE ALONG THE EDGE TO PREVENT ANY FURTHER LEAKING


Todd C.

Todd C. Job Checkin

DELFIELD INSTALLED DROP IN


ANTHONY M.

ANTHONY M. Job Checkin

HOSHIZAKI ICE MACHINE LEAKING WATER, PUMP IS NOT WORKING CLEANED THE CONDENSATION PUMP AND UNIT IS WORKING


ANTHONY M.

ANTHONY M. Job Checkin

HEAT CRAFT DELI COOLER THE GAGE ON THE OUTSIDE ISNT READING RIGHT CONDENSER WAS CLOGGED AND FOUND THE EVAPORATOR FAN WAS NOT COMING ON FOUDN IT HAD LOOSE WIRE CLAMPS RECLAMPED THE WIRES AND UNIT IS WORKING


ANTHONY M.

ANTHONY M. Job Checkin

HOSHIZAKI ICE MACHINE NOT FUNCTIONING PROPERLY FOUND WATER WAS TURNED OFF TO THE BUILDING


Brick  B.

Brick B. Job Checkin

Troubleshooting a Hoshizaki ICE MACHINE that is leaking. Found issue with condensation pump and will have to replace. Got customer running in meantime.


Brick  B.

Brick B. Job Checkin

Troubleshooting a Hoshizaki ICE MACHINE that is leaking. Found issue with condensation pump and will have to replace. Got customer running in meantime.


Richard G. G.

Richard G. G. Job Checkin

Hoshizaki ice machine KLM-451MAH leaking at top. Replace the cracked inlet tube assembly with adapter and. Supply line.