dynamic appliance repair A customer reported that their Monogram built-in refrigerator was not cooling properly. Upon inspection, I found that the refrigerator's temperature settings were correct, but the cooling system was not functioning. I began by checking the condenser coils for any signs of dirt or debris, which can impede cooling efficiency. After cleaning the coils, I tested the refrigerator again, but it still wasn't cooling. I then examined the evaporator fan motor, which was not running. I replaced the faulty motor and tested the refrigerator once more. This time, the refrigerator was cooling as expected. I also checked the door seals for any gaps that could cause cold air to escape, ensuring they were tight and functioning properly. The refrigerator is now operating efficiently, and the customer is satisfied with the restored cooling performance.