Completed low pressure switch repair on refrigeration system by identifying and repairing leaking braze joint. Service included complete refrigerant recovery, system evacuation, and proper recharge, with electrical measurements confirming proper operation at 0.93A as verified with Klein Tools CL390 clamp meter.
Performed comprehensive preventative maintenance on two 2018 HVAC units. Completed full 80-point inspection on each system including cleaning of outdoor coils, burner cleaning, and gas pressure adjustments. Conducted electrical testing with multimeter to verify proper voltage and amperage readings within manufacturer specifications, confirming all systems operating normally with no issues identified.
Completed 32-point electrical system evaluation on 2018 home. Performed panel maintenance including torque verification and connection inspection. Tested all GFCI/Arc Fault protection devices for proper functioning. Replaced batteries and tested smoke/CO2 detectors. Visual inspection of main electrical panel and exterior meter connection showed all components in normal operating condition with proper labeling.
Electrician installing outlets above cabinets and whole home surge protection
Electrician installing foyer light, ceiling fans, and repairing circuit