403 Headquarters Dr. Unit 5
Millersville, MD 21108
(443) 396-3797

Local Reviews
for baltimore, md

Rated 5.0 out of 5 stars based on 5 customer reviews

Excellent service!

Micheal did a great job in our electric work! Always on time and got the job done!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Very helpful on short notice

Looked all over for an electrician who could help with a relatively small, but vital job on relatively short notice. Found Haas and Sons bc of their great reviews. Although we ran into a snag, I was impressed with the way it was handled. Electrician was very nice, explained the issues, helped me identify a workable solution, and performed the work without delay. What more can you ask for? Happy customer here!

  • Overall Experience
  • Quality
  • Price
  • Convenience

5 star service, went the extra mile !

Not only did a wonderful job getting my 50 amp electric car charger running, helped with customizing outside hangers and plug location, also put in a new plug in basement for my electric dryer as well, phenomenal electric service in a house that is over 100 years old!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Quality Work and Great Service

Nathan and Alex were great! They were professional and considerate of our home and pets. They wore masks and gloves when speaking with me and listening to my questions. The pricing for the two closely related jobs seemed to run together so it was more than I expected to pay. However, I cannot argue with their superb work.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Nick needs a raise!

He was phenomenal. Got everything done in less time than he said.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for baltimore, md

Nicholas T.

Nicholas T. Job Checkin

Reason for today’s visit was to install receptacles for heated toilet seats. Customer installed three heated toilet seats total. There is two on the top floor and one on the first floor. The first floor GFCI I tapped out of the two gang switch bank right beside the toilet. Second floor hallway, bathroom I tapped out of the GFCI on the vanity and ran the line down through the cabinet and behind the toilet and installed a standard receptacle that is protected by the bathroom Gfci. The final install was in the primary bathroom on the second floor in which we tapped out of the vanity receptacle on the opposite side of the wall This receptacle was protected by the GFCI on the opposite side of the vanity. The heated seats pull a total of .53 A each.


Genny G.

Genny G. Job Checkin

Customer wanted to add additional washer and dryer circuit for 2nd floor tenants. Work performed today: Install new dryer and washer circuit in basement Let us know if your have any questions. Thank you for your continued business!


dennis@haasandsons.com

dennis@haasandsons.com Job Checkin

Installation of new dedicated 20 amp circuit for garage refrigerator. Adding surge protection to home to prevent harmful voltage spikes damaging appliances.


dennis@haasandsons.com

dennis@haasandsons.com Job Checkin

Install customer supplied car charger and landing it on a 50 amp Siemens breaker. Install customer supplied TV with customer supplied mounting bracket and hardware. Install customer supplied dead-bolt and door handle. Install customer supplied Google Nest doorbell by cutting access through sheet rock. Replacing 7 receptacles in front room on first floor. Replacing GFCI receptacles on washer, kitchen counter, wet bar, and garage. Updating smoke and carbon monoxide detectors throughout home.


Matt M.

Matt M. Job Checkin

Troubleshoot tripping breaker


Alan S.

Alan S. Job Checkin

Install ground rods and full grounding bonding package for cold water main coming into home as well as gas main for the home. Bond water heater hot to cold copper lines as they are currently not grounded. Also install new hardwired co2 detectors on each floor currently only has basement and second floor hardwired but not interconnected. We will interconnect both current c02 detectors and add one on the 1st floor living room area. Also install and interconnect 2 new smoke detectors for bedrooms on second floor.recommend whole home surge protection to protect all electronics in the home from future lighting storms or electrical surges from damaging any sensitive appliances or electronics.


Michael W.

Michael W. Job Checkin

This estimate includes the installation of a dedicated circuit for the fridge, sump pump and microwave. In addition we shall re-device the home (new plugs and switches). Lastly we shall repair the basement 3way lighting, strap the service cable and demo all unsafe hanging receptacles and unnecessary wiring. We have begun the repairs and shall return next Friday to continue scheduled work. We have returned, we have demoed the existing basement electrical associated with the hanging wires and boxes. We have rewired these lights, installed a new means of switching for the stairwell light and correctly wired the 3way switch. In addition we have installed a new dedicated the circuit for the microwave and have have installed a new stove receptacle. We shall return on the 13th of March to continue with repairs. We have returned and installed the fridge and sump pump dedicated circuits. In addition we have strapped the service cable and updated the bonding and grounding at the water heate


Alex W.

Alex W. Job Checkin

I removed and replaced a kitchen light with a customer supplied kitchen light and I removed and replaced a bedroom ceiling fan with a customer supplied ceiling fan


Nicholas T.

Nicholas T. Job Checkin

Ej2- we added a dedicated 30 amp 240 volt circuit next to the main panel in the basement for a dryer. We also replaced doorbell transformer located in the basement panel area (in the ceiling light). Ej1b- we relocated dryer outlet in the 2nd floor laundry room over to the opposite wall in the back corner. EL2A- we replaced customer supplied bathroom exhaust fan and replace existing 3 gang switch box with a 4-gang switch box so that the fan and the light can be switched separately. We removed the existing light next to the fan since it will no longer be needed. We swapped out the surface mounted light in 2nd floor laundry room with a new customer supplied light while on site.


Alex W.

Alex W. Job Checkin

Removed a two prong outlet in living and replaced it with a gfci receptacle 30 day warranty


Nicholas T.

Nicholas T. Job Checkin

Installed new ceiling fan rated box in the center of the exercise room. We converted the existing switch into the switch for the new light location. We installed 3 new customer supplied ring lights on the outside of the home and swapped doorbell for new customer supplied ring doorbell. We labeled panel and sub panel.


Nicholas T.

Nicholas T. Job Checkin

Installed 3 new led recessed lights in bulk head over the kitchen counter. Installed 3 customer supplied track lights in the kitchen. I relocated the ceiling fan in the master bedroom roughly 15 ft closer to the master bed and removed the existing fan. I installed a new ceiling fan in the living room on the 1st floor and tied into the original switched outlets switch. The original switched outlet is now a standard outlet.


Nicholas T.

Nicholas T. Job Checkin

Installed new switch and wiring to existing light in the master bathroom. We found a broken line running out to the hot tub plug.


Alex W.

Alex W. Job Checkin

Installing car charger

Installing car charger

Alex W.

Alex W. Job Checkin

Installing light fixtures

Installing light fixtures