Customer had a gfci circuit that was out due to a power outage I found the customer had multiple gfcis on this circuit and they were line sided and load sided. So when the power went out you had to find the correct sequence of gfcis to reset to get them all back online So I removed all the receptacle devices in all bathrooms one in garage and 3 outside and then spliced all the appropriate wires together and pig tailed off the splice then installed tamper resistant GFCIs inside and line sided the wires. Then I went outside and installed weather resistant GFCIs and in use bubble covers in all locations and siliconed around the boxes to protect the devices from wether elements as much as possible. With line siding the devices, if a device fails it will not affect the other devices on the circuit Customer has a 1 year warranty