This solution includes Running a 6-2 seu copper cable from main electrical panel. Drilling a whole through concrete and running the wire outside. The wire is weather rated. Then sealing the hole around the wire to prevent water getting into home. Then installing a customer supplied HARD WIRED car charger. Then in the panel installing a 60 amp square d qo 2 pole electrical breaker We will install a whole home surge protector thats powered by a 2 pole 50 amp square d qo electrical breaker. This is to protect the new car charger and car and other electronics throughout home from potential power surges We will remove all double tapped neutrals in panel. Install ground bar to open up spaces on neutral bar. It’s code requirements that neutrals are on their own separate screw to prevent back feeding circuits and to lower chances of overheating the screw terminals