Job Checkin

Removed and replace all devices on circuit which was the devices in both guest bedrooms most of the mast bedroom the hallway light and the hallway bathroom on 2nd floor. Also the kitchen lights I spliced all my appropriate wires together then pig tailed off the splice with one wire then stripped the wire, hooked it around the device screw and clamped it then tightened it down. This is the best possible connection possible. The outlets and switches that were there previously were 30 years old and some had burnt from being back stabbed so customer was loosing power then the power would come back on its own which is dangerous. I also installed two pole breakers where they are required for 14-3 wires in panel and I installed a micro surge protector for the whole home. The 2 pole 15 amp BR arc fault breaker is on back order and we will order that ASAP and once it comes in we will notify the customer so we can come out and install arc fault protection on the circuit I worked on Customer wa