This was my 2nd time calling on Haas & Sons and once again they provided exceptional service that was timely!! They can be trusted for their expertise and I will always give them a call in the future!
The company responded quickly with an appt for us. The tech that came was very professional and personable. He knew exactly how to fix our issues and did so the same day. Very courteous and fully vaccinated!! The next time I need an electrician, I’ll call Haas
Installation of two new sconce boxes located in bedroom on second floor. We would extend power from the outlet below and feed two old work boxes for wall style sconces. Installation of a new Panasonic whisper exhaust fan located in the primary bedroom full bath. We would re-attach to the existing venting/ducting. We were called out today to provide solutions for the installation of two wall sconces in a bedroom. While on site, we provided additional solutions to replace three bath fans and add surge protection to the panel. Customer agreed to the solutions for the wall sconces and to replace one of the bath fans in the master bathroom. Customer did not yet have the wall sconces, so we extended the circuits to two new work boxes and blanked them off. We also replaced the receptacle from the location where we extended the circuit, as well as the switch in the bathroom controlling the fan.
Installed new receptacle in primary bathroom for bidet Install new GFCI receptacle in powder room bathroom for bidet.
Installation of a new outlet located in the foyer closet to supply power for a low voltage door bell transformer. We would then install the transformer and run the wire to the exterior mount for the Ring.
Arrived onsite and was told about the issue at hand. Immediately from the age of the home i knew it was one of a few possibilities, so i walked the resident through the things i was going to look at, and he came with me for my inspection. He showed us an outlet under the stairs that had lost power, that his wifi derived from. He told me that went out when the outside Christmas lights went out. I asked to see the unfinished areas/utility rooms in the basement and explained i was looking for the house GFCI, that would be controlling those outlets. I found it in the same room as the furnace, tripped after a rainstorm. I went to all the outside outlets and did a visual inspection and the front one was fine, but the side and back one had broken w/p tabs inside and the in use cover seals were so degraded that not only did water get in but both covers had a thick layer of green growing in them. I talked to the resident about replacing the WR outlet and in use covers had a for those two locati
Replaced burnt up dryer receptacle. Provided pricing for new circuit for 240 V dryer as well as main panel replacement and safety and code updates.
I removed a ring security light by the garage doors. The wires went straight to the light so i installed a siding block and siliconed around the sides to prevent water getting into the hole. Then i installed a new ring security customer supplied light Customer did not have other electrical projects at this time
Today’s visit was for installing EV charger receptacle. I also recommend surge protection to protect home and your vehicle. Customer declined. Please see below for work performed: Install EV charger receptacle in garage with GFCI breaker Also, please attached quote if you decide to go hardwired in the future. Thank you!
Troubleshot new pool heater to find that there’s something wrong with the unit when it starts up. Unit is pulling 172 A are very short. Before dropping down which is causing the breaker to hum. Also, on site we installed a customer supplied floodlight on the back of the home and a pre-wired location. Replace floodlight on second story from the back of the home. Installation of customer supplied light
The reason for today’s visit with customer was a scheduled appointment to quote adding a receptacle to his garage for an EV charger port. After greeting with customer, we then went to the garage and assessed the area of where the charger plug would go. I saw a 3/4 inch EMT run that went to the panel ran in 6 THHN stranded copper conductor. The customer stated he had a universal plug adapter for the current tesla charger and he wanted to optimize his charging capabilities. After going over the details we then were taken to the panel which was located in the back bedroom on the second floor. The panel was a 2011 Siemens 150 amp panel with dual function breakers and one mix-matched Eaton BR breaker. I recommended to the customer we replaced the incorrect breaker along with any work he decided on scheduling for the EV charger. I went over two options for the EV charger such as the customer buying an actual wall unit EV charger and us installing it or us installing a 240v 50 amp receptacle
Installation of new customer supplied ceiling fan located in the bedroom on the second floor. With installation, turning current switch controlled outlet into a constant hot outlet and replacing the switch that currently controls that outlet.
This solution includes the installation/relocation of 2 existing receptacles to a new and higher height located within the new built in cabinet. We have relocated the existing wire for the 2 receptacles. Once the built in cabinet is in place customer to install the boxes. Arc fault protection installed in panel. Circuit was tested and works, however it shall remain off until cabinet completion.
We have delivered pricing regarding the deck project.
installation of new GFCI located in primary bathroom on second floor with properly terminating aluminum wiring with alumicon connectors. With doing so removing current single gang outlet and replacing with a 2gang outlet to further assist alumicon connectors and adding another receptacle protected by the current GFCi. Installation of GFCi located in hall bath on second floor and properly terminating.
This solution includes the installation of new decora switches in the kitchen area, 9 total. In addition we shall replace the 3 pendant lights with new customer supplied lighting. We shall correct the chandelier height. We have installed the new customer supplied lighting in the kitchen. In addition we have replaced existing switches in the kitchen area. 8 total.
Reason for today’s visit was to assess power loss to the primary bedroom as well as the garage lights. Customer stated the breaker had tripped a few times, and now would not reset. I checked the main panel and found that the breaker controlling the affected circuit was dead shorting immediately when trying to be reset. First thing I did was open up the panel and found that most of the circus have been transferred down to a sub panel below the main which had a hook up for a back up portable generator. The main panel was a 200 amp Square D panel that was original to the home. There was another 200 amp Square D panel next to this panel that had been replaced. For whatever reason the left panel was never replaced. The right panel appears to have been replaced but without a permit. There was never surge protection installed or emergency disconnects. And then began troubleshooting the circuit at the garage, because customer stated he had previous issues with the garage switch. When I opened