403 Headquarters Dr. Unit 5
Millersville, MD 21108
(443) 396-3797

Local Reviews
for jessup, md

Rated 5.0 out of 5 stars based on 5 customer reviews

Excellent Service

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent Service!

Very Professional and friendly! Very knowledgable in electrical work. But pricing is a little on the high end.

  • Overall Experience
  • Quality
  • Price
  • Convenience

great service

Alex was amiable, and a very serious worker. He immediately put me at ease with full confidence, even when I added other minor work. I am planning another job for him, and I know it will be done right. Most important, the women in the family are ecstatic. Fully satisfied. Yes, cost is a bit higher than I wanted, but I want to have full trust in the work and expected that going in.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Thorough and professional

Nick was thorough, professional and patient. He took time to explain the work he was doing.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Fantastic experience

This is my second time hiring this company. Michael was fantastic. He went above and beyond. He got all five of my ceiling fans installed and working correctly with the other smart devices in my home.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for jessup, md

Michael W.

Michael W. Job Checkin

This solution includes the replacement of 2 existing receptacles in kitchen and the replacement of the microwave box and receptacle. We have replaced the microwave receptacle and box. In addition we have made wiring repairs to the receptacle under the mixer station and behind the stove.


Nicholas T.

Nicholas T. Job Checkin

Replaced 3 hardwired with lithium 10 year backup battery smoke detectors


Alex W.

Alex W. Job Checkin

I installed clamps on the neutral wire in the main electrical panel on the two circuits that continue to trip customers arc fault breakers


Michael W.

Michael W. Job Checkin

This solution includes the replacement of the breaker controlling microwave and range. In addition we shall replace the breaker controlling the appliance circuit. We have replaced the 2 existing breakers.


Michael W.

Michael W. Job Checkin

This estimate includes a wiring repair to establish ground to the upstairs receptacles. We have grounded the upstairs receptacles in the bedroom. We recommend having the wet location areas to have gfci protection.


dennis@haasandsons.com

dennis@haasandsons.com Job Checkin

Installation of new whole home surge protection to prevent harmful voltage spikes while also protecting home appliances.


Alex W.

Alex W. Job Checkin

Service charge


Michael W.

Michael W. Job Checkin

This solution includes the installation of a customer supplied EV charger. We have installed the customer supplied Charge Point EV charger.


Michael W.

Michael W. Job Checkin

This solution includes the installation of a new Arc-fault breaker for the master bedroom circuit. We have installed a new breaker to control the master bedroom.


Alan S.

Alan S. Job Checkin

Install new receptacle in living room behind tv within the exterior insulated wall using existing receptacle directly underneath location of tv. Install new receptacle in office closet on second floor using existing circuit from outlet in the hallway on opposite side of the wall in closet. Install new receptacle in daughters bedroom on second floor for nightlight in her closet using existing circuit and receptacle on opposite side of wall in bedroom.


Matt M.

Matt M. Job Checkin

Replace the receptacles in the 2 bathrooms upstairs Repair double tapped neutrals in the panel Install whole home surge protector


Michael W.

Michael W. Job Checkin

This estimate includes the installation of a customer supplied whole home surge protector. We have returned and installed the customer supplied surge protector.


Michael W.

Michael W. Job Checkin

This estimate includes the installation of a dedicated 120V 20A circuit to be terminated in a GFCI receptacle at the customer’s desired location. In addition we shall install a stack switch to replace the 2 single pole switches at garage, this shall allow space for a new GFCI receptacle. We have collected the deposit and shall return next Wednesday to complete the scheduled work. We have completed the scheduled work of the installation of the new dedicated garage circuit in the installation of a GFCI and stack switch by the doorway to the home.


Alex W.

Alex W. Job Checkin

I ran a dedicated circuit from the main electrical panel in the basement to a designated area customer will use for gym equipment. I ran a 20 amp circuit (12-2 romex) and stapled it throughout the unfinished basement ceiling from the panel and then installed a single gang new work box with a tamper resistant receptacle and a nylon unbreakable plate. Then in the panel i installed a 20 amp single pole square d homeline arc fault/gfci breaker combo #review


Michael W.

Michael W. Job Checkin

We have troubleshot the power loss at the home and concluded that at the disconnect at the meter stack does not have 240V leaving the disconnect. However leaving the meter, 240V is present. The breaker in the disconnect enclosure is bad and needs to be replaced. In addition, due to the existing and inherently dangerous installation of the existing electrical wiring feeding the home’s service panel we cannot perform a repair. Lastly the land from the meter stack to the home is not owned by the homeowner, so this task of correctly installing feeder wires to the home, C-20, might fall on the management company who owns the land.