Customers outdoor receptacle circuit was non operational. There was two faults in the circuit causing all devices to not have power. Faults were most likely caused by bad seals on receptacle covers. Removed all 3 outdoor receptacles and installed new weather resistant devices and in use covers. The front plug is protected by the garage gfci which was also replaced. The back receptacles are protected by the gfci open the deck. Also replaced the siding block on the back deck receptacle due to a large hole cut in the back of it leaving the wood exposed on the house next to live wires. Verified proper operation of all completed work with customer.