i removed and replaced the receptacles on the home gfci circuit I replaced them all with gfcis and outside got weather resistant gfcis with in use bubble covers I spliced all the appropriate wires together and pigtail off the spices landing the wires on the line side of the GFCI what this does is it still says power throughout the circuit even if something were to trip outside due to weather or power washing the outside receptacles will not affect the inside so the customer will not have to worry about Internet going down I also removed a weather proof box that was damaged and installed a siding block in its place I demoed wires that went outside under the deck and in the pavilion in back yard due to another “electrician” running them against code causing issues in the circuit and also it was a safety issue for the home owner I ran a dedicated circuit 20 amp circuit which is arc fault protected and gfci protected from the main electrical panel to the sump pump in the basement Custo