403 Headquarters Dr. Unit 5
Millersville, MD 21108
(443) 396-3797

Job Locations
for severna park, md


Map of Severna Park MD
dennis@haasandsons.com

dennis@haasandsons.com


Job Checkin

Installation of new 15 amp BR breaker to eliminate double tapped breaker circuit. Panel correction with removal of violations such as double tapped neutrals. Adding GFCI breaker to sump pump circuit which is also the washer circuit due to devices being within 6 ft of water and not having correct safety requirements. Installation of whole home surge protection to further assist home in protection against harmful voltage spikes and protecting home appliances. Adding gas/water bond due to all metallic systems requiring proper grounding means. Adding cold water ground via cold water intake pipe and running proper sized ground back to panel.