403 Headquarters Dr. Unit 5
Millersville, MD 21108
(443) 396-3797

Local Reviews
for woodbine, md

Rated 5.0 out of 5 stars based on 5 customer reviews

Good service.

Alan did a fine job. Came during designated time.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service. Good suggestions.

Always call Haas and ask for Alex.

  • Overall Experience
  • Quality
  • Price
  • Convenience

EV installation

Larry was very professional, right on time and well versed in his field. Great customer service

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service

Alex always does a great job.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Fantastic.

Alex was very helpful on selecting a better outside light. I asked him if he was the owner’s son because he was so caring, knowledgeable, professional.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for woodbine, md

Nicholas T.

Nicholas T. Job Checkin

Install missing GFCI protection in exterior plugs, 1st floor bathroom, garage, both sump pumps, basement freezer, central vac and panel receptacle. Replace undersized panel with a new 200 amp main breaker panel with 42 spaces to accommodate existing breakers and room for growth. Installation of new service cable to main panel as well as an emergency disconnect, whole home surge protection and service cable from meter canned to new disconnect. Install new ground rods to accommodate new grounding code requirements.


Alan S.

Alan S. Job Checkin

Remove existing smokes and replace with 3 new wireless interconnected hardwired smoke/co2 combos’ one on each floor.


Nicholas T.

Nicholas T. Job Checkin

Disconnected batteries from units. New hardwired wirelessly connected units are ordered to contact customer once they arrive so we can install them.


Matt M.

Matt M. Job Checkin

Install new dining room chandelier and remove the existing light boxes Replace switches 4 in the kitchen


Michael W.

Michael W. Job Checkin

We have installed 3 new exterior fixtures and siding blocks, customer supplied.


Nicholas T.

Nicholas T. Job Checkin

We will return to complete work once the QO 20 amp and 15 amp 240 volt GFCI breakers come in. We will install new 240 volt lines to the areas where the mini split units will be installed. We will install service disconnects on the outside of the home and provide wired whips off the disconnects that the HVAC company will tie into the new units. We will install new GFCI breakers to power and protect units. 6/8 Returned today and ran 2 new 240v circuits and installed weather resistant disconnects on the exterior of home as quoted. I installed new 240v GFCI breakers in the newer panel in the basement unfinished area. I left disconnects in the off position so that the tails will not be live until units are installed.


Alex W.

Alex W. Job Checkin

I removed the tubes in the lights in garage and re wired and re supported the lights I installed 8 foot LED ballist bypass tubes I installed three hard wired wireless interconnected smoke/carbon monoxide detectors The upstairs I used the existing box from the previous smoke alarm The 1st floor I fished up the wall from a receptacle and installed a old work box and replaced the receptacle The basement I went from a light fixture with a constant hot and a neutral and fed the new device I fished out the garage receptacle over to the side of the garage (front of home) and then drilled a hole outside to install a siding block and installed a company supplied high powered motion light Customer has a 1 year warranty on all work preformed


Nicholas T.

Nicholas T. Job Checkin

Installing new customer supplied exhaust fan with light and heater in the master bathroom. We ran a new dedicated 20 amp 120 volt circuit to a new set of switches outside the bathroom and ran new switches legs up into the attic. We will be returning on Wednesday to complete work. 11/17 Returned today and installed customer supplied bath exhaust fan/light/ heater. We installed new 4inch through the roof gooseneck vent out and sealed with roofing tar. Once installed we tested unit out and it was working properly.


Larry B.

Larry B. Job Checkin

Installed a new circuit from panel in basement to garage for a sub panel. Wire is #2 aluminum SER on a 90 amp breaker. From sub panel installed a 60 amp circuit for a customer provided tesla wall charger. Verified proper operation of all completed work with customer. Work is getting inspected.


Alex W.

Alex W. Job Checkin

I ran a 6-3 romex wire from the main electrical panel to the upstairs kitchen behind the range. I installed a 4 prong flush mount outlet. Then removed the older 8-2 aluminum wire from the panel that powered up the older range and I landed my new circuit on a 50 amp gfci 2 pole breaker due to the sink being within 6 feet of the new plug upstairs. I removed and replaced a light fixture in the master bathroom Customer has a 1 year warranty on the oven circuit


Alex W.

Alex W. Job Checkin

Installed two customer supplied ceiling fans in upstairs bedrooms Ran new switch leg installed two gang switch box Two new switches Removed and replaced attic fan motor


Nicholas T.

Nicholas T. Job Checkin

Denise_e_r@hotmail.com Installed 2 whole home surge protectors in main panels located in the basement (400 amp service). These whole home surge protectors extend the life of appliances up to 30% longer and safeguards against big surges. The rating on them is how large of a surge they can handle before self sacrificing themselves to save your equipment.  The ultra surge protector protects entire home from power surges, computers, TV's and other sensitive equipment. Comes with $75,000 manufacture warranty and handles 108,000 amp power surges. 


Alex W.

Alex W. Job Checkin

Installing outside lights

Installing outside lights