Arrived on the job site. The customer stated that the breaker controlling the Christmas lights in the eaves was tripping randomly. I inspected the circuit and found that it was on a Siemens plug-on-neutral AFCI/GFCI combination breaker. When testing each individual set of Christmas lights, they worked fine, but when all three were plugged in together, the breaker would trip. Because this circuit feeds exterior outlets, it does not require AFCI protection. I replaced the breaker with a UL-listed Siemens 15-amp CL standard breaker. I also verified the home run feeding the GFCI outlet to the left of the panel, which supplies power to the new timer controlling the eave outlets. The timer was preset to turn on at 6 p.m. and turn off at 4 a.m. The customer is 100% happy and satisfied with today’s visit and understands that all work performed comes with a five-year warranty on labor and materials.
Pull toilet in master bath and inspect flange and line, reset toilet with new wax ring bolts and caps. If flange is damaged additional repairs will be needed.
Installed dedicated circuit for barn power, ceiling fans, lights
Install first responder disconnects, install main breaker panels, install sub panels, pull new AC circuits, install smoke detectors, install grounding system, install whole home surge protection, install GFCI protection, install light fixtures, install LED fixtures, install recessed lighting, pull new wiring, install outlets