Mike did a fantastic job installing a new overhead light fixture in my home office. He was very professional, knowledgeable, and delivered the service quickly and at a very fair price. He was a real pleasure to work with and I will call them again!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for hurst, tx

Marco B.

Marco B. Job Checkin

Customer called wanting a new outlet installed. Installed outlet under two gang switch box in back right office using existing wiring. Tested and working fine. Customer is happy with the installation

Customer called wanting a new outlet installed. Installed outlet under two gang switch box in back right office using existing wiring. Tested and working fine. Customer is happy with the installation Customer called wanting a new outlet installed. Installed outlet under two gang switch box in back right office using existing wiring. Tested and working fine. Customer is happy with the installation

Marco B.

Marco B. Job Checkin

Customer called wanting to replace an FPE breaker with another customer supplied breaker. Informed customer about the history of these panels and why we don’t service them. Left options for replacement

Customer called wanting to replace an FPE breaker with another customer supplied breaker. Informed customer about the history of these panels and why we don’t service them. Left options for replacement Customer called wanting to replace an FPE breaker with another customer supplied breaker. Informed customer about the history of these panels and why we don’t service them. Left options for replacement

Marco B.

Marco B. Job Checkin

Troubleshoot and repair kitchen light switch controlling overhead light and sink light not working properly, includes replacing the 3 smart switches and correcting all connections in the junction box and repairing connections in living room switch box. Found incorrect splices copper and aluminum connections in kitchen 3 gang junction box. Replaced 3 smart switches with standard switches, made correct copper to aluminum pigtails. Kitchen lights are not working properly with newer wiring indicating an attic junction box with loose connections. Lights also have no junction boxes. Informed customer that there needs to be junction boxes installed in order to safely connect the lights fixtures. Also discussed making the correct type copper to aluminum connections throughout the rest of the home. Left options for all work described including adding AFCI protection (required as per code with pigtails), surge protection and a new circuit to the back patio

Troubleshoot and repair kitchen light switch controlling overhead light and sink light not working properly, includes replacing the 3 smart switches and correcting all connections in the junction box and repairing connections in living room switch box.

Found incorrect splices copper and aluminum connections in kitchen 3 gang junction box. Replaced 3 smart switches with standard switches, made correct copper to aluminum pigtails. Kitchen lights are not working properly with newer wiring indicating an attic junction box with loose connections. Lights also have no junction boxes. Informed customer that there needs to be junction boxes installed in order to safely connect the lights fixtures. 

Also discussed making the correct type copper to aluminum connections throughout the rest of the home. Left options for all work described including adding AFCI protection (required as per code with pigtails), surge protection and a new circuit to the back patio Troubleshoot and repair kitchen light switch controlling overhead light and sink light not working properly, includes replacing the 3 smart switches and correcting all connections in the junction box and repairing connections in living room switch box.

Found incorrect splices copper and aluminum connections in kitchen 3 gang junction box. Replaced 3 smart switches with standard switches, made correct copper to aluminum pigtails. Kitchen lights are not working properly with newer wiring indicating an attic junction box with loose connections. Lights also have no junction boxes. Informed customer that there needs to be junction boxes installed in order to safely connect the lights fixtures. 

Also discussed making the correct type copper to aluminum connections throughout the rest of the home. Left options for all work described including adding AFCI protection (required as per code with pigtails), surge protection and a new circuit to the back patio

Marco B.

Marco B. Job Checkin

Customer had a two wire system with two prong plugs and no ground. White wanted to install three prong plug so explained what is going to be required when we update the system to three prong outlets. Calling back next Thursday” is good for 30 days.

Customer had a two wire system with two prong plugs and no ground. White wanted to install three prong plug so explained what is going to be required when we update the system to three prong outlets. Calling back next Thursday” is good for 30 days. Customer had a two wire system with two prong plugs and no ground. White wanted to install three prong plug so explained what is going to be required when we update the system to three prong outlets. Calling back next Thursday” is good for 30 days.

Alex C.

Alex C. Job Checkin

Met onsite with city inspector to pass the final inspection.

Met onsite with city inspector to pass the final inspection. Met onsite with city inspector to pass the final inspection.

Tyler B.

Tyler B. Job Checkin

Returned to installed interlinked smoke detectors in all required locations and answered any questions and concerns customer had everything working properly.

Returned to installed interlinked smoke detectors in all required locations and answered any questions and concerns customer had everything working properly. Returned to installed interlinked smoke detectors in all required locations and answered any questions and concerns customer had everything working properly.

Tyler B.

Tyler B. Job Checkin

Customer called about intermittent power loss as well as flickering lights throughout the home. Found meter base and panel enclosure is arcing. Nipple between panel and meter is fused together as well as significant heat damage to the main breaker lugs in the panel. Left option for replacement

Customer called about intermittent power loss as well as flickering lights throughout the home. Found meter base and panel enclosure is arcing. Nipple between panel and meter is fused together as well as significant heat damage to the main breaker lugs in the panel. Left option for replacement Customer called about intermittent power loss as well as flickering lights throughout the home. Found meter base and panel enclosure is arcing. Nipple between panel and meter is fused together as well as significant heat damage to the main breaker lugs in the panel. Left option for replacement

Alex C.

Alex C. Job Checkin

Submitted photo to inspector per his request and passed the final inspection. Scheduled a warranty return for issue with toilet. Scheduled backfill for today as well with customer preference mounded at tunnel opening so it can settle properly.

Submitted photo to inspector per his request and passed the final inspection. Scheduled a warranty return for issue with toilet. Scheduled backfill for today as well with customer preference mounded at tunnel opening so it can settle properly. Submitted photo to inspector per his request and passed the final inspection. Scheduled a warranty return for issue with toilet. Scheduled backfill for today as well with customer preference mounded at tunnel opening so it can settle properly.

Blake L.

Blake L. Job Checkin

Customer wanted quote on fixing service mast that has wires very close and about to touch and explained that we will only replace the whole thing if we work on it due to liability issues. Customer will give us a call back when he is ready for the work to be done. Quote is only good for 30 days.

Customer wanted quote on fixing service mast that has wires very close and about to touch and explained that we will only replace the whole thing if we work on it due to liability issues. Customer will give us a call back when he is ready for the work to be done. Quote is only good for 30 days. Customer wanted quote on fixing service mast that has wires very close and about to touch and explained that we will only replace the whole thing if we work on it due to liability issues. Customer will give us a call back when he is ready for the work to be done. Quote is only good for 30 days.

Marco B.

Marco B. Job Checkin

Added educated circuit for dining room with 3 outlets added floodlight outside of garage also replaced 2 front sconse lights and 2 back lights replaced existing doorbell and made sure circuit was arch fault protected

Added educated circuit for dining room with 3 outlets added floodlight outside of garage also replaced 2 front sconse lights and 2 back lights replaced existing doorbell and made sure circuit was arch fault protected Added educated circuit for dining room with 3 outlets added floodlight outside of garage also replaced 2 front sconse lights and 2 back lights replaced existing doorbell and made sure circuit was arch fault protected

Alex C.

Alex C. Job Checkin

System does not need to be put on test to be inspected so will close out after inspection passed

System does not need to be put on test to be inspected so will close out after inspection passed

Alex C.

Alex C. Job Checkin

Met inspector onsite with homeowner and passed the final inspection.

Met inspector onsite with homeowner and passed the final inspection. Met inspector onsite with homeowner and passed the final inspection.

Tyler B.

Tyler B. Job Checkin

Arrived on the job site. Customer stated that the circuit controlling the living room was not working properly, intermittently losing power, and his plug tester was showing a “hot-to-ground reverse” reading. Prior to my arrival, the customer had checked several outlets himself, except for two on the same circuit. I inspected the two outlets he had not checked and found that one of them had a bad connection. I replaced the outlet, which powers the ADT security system, and informed the customer that it carries a five-year warranty. I also notified the customer that I would be performing a full safety evaluation. Upon opening the panel, I found that the bar connecting the main breaker to the bus bar was severely damaged, showing heat damage and discoloration. I explained to the customer that this is not safe and that, given the age of the home (built in the 2000s), the electrical panel is within the typical 20–25 year replacement range. The panel also had multiple tandem breakers install

Arrived on the job site. Customer stated that the circuit controlling the living room was not working properly, intermittently losing power, and his plug tester was showing a “hot-to-ground reverse” reading. Prior to my arrival, the customer had checked several outlets himself, except for two on the same circuit. I inspected the two outlets he had not checked and found that one of them had a bad connection. I replaced the outlet, which powers the ADT security system, and informed the customer that it carries a five-year warranty.

I also notified the customer that I would be performing a full safety evaluation. Upon opening the panel, I found that the bar connecting the main breaker to the bus bar was severely damaged, showing heat damage and discoloration. I explained to the customer that this is not safe and that, given the age of the home (built in the 2000s), the electrical panel is within the typical 20–25 year replacement range. The panel also had multiple tandem breakers install Arrived on the job site. Customer stated that the circuit controlling the living room was not working properly, intermittently losing power, and his plug tester was showing a “hot-to-ground reverse” reading. Prior to my arrival, the customer had checked several outlets himself, except for two on the same circuit. I inspected the two outlets he had not checked and found that one of them had a bad connection. I replaced the outlet, which powers the ADT security system, and informed the customer that it carries a five-year warranty.

I also notified the customer that I would be performing a full safety evaluation. Upon opening the panel, I found that the bar connecting the main breaker to the bus bar was severely damaged, showing heat damage and discoloration. I explained to the customer that this is not safe and that, given the age of the home (built in the 2000s), the electrical panel is within the typical 20–25 year replacement range. The panel also had multiple tandem breakers install

Alex C.

Alex C. Job Checkin

Started backfill on trench and provided quotes to replace for exhaust fan in the hallway restroom. Price is based on customer supplied fan. Recommend going with a higher sone rating and that is how quiet the unit will be while operating.

Started backfill on trench and provided quotes to replace for exhaust fan in the hallway restroom. Price is based on customer supplied fan. Recommend going with a higher sone rating and that is how quiet the unit will be while operating. Started backfill on trench and provided quotes to replace for exhaust fan in the hallway restroom. Price is based on customer supplied fan. Recommend going with a higher sone rating and that is how quiet the unit will be while operating.

Alex C.

Alex C. Job Checkin

Passed inspection - Alex will backfill.

Passed inspection - Alex will backfill.