Met inspector onsite and had the system on test as well as provided video to show the system was not leaking. Removed test equipment and passed final inspection. Let pro source know the site is ready for backfill and dirt preference outside of tunnel is mounded so dirt can settle flat.
Arrived to look at issue with the garage circuit after we had already worked on it the line had lost power. Remade the connection in the back of the box and found that the gfci that we had installed had faulted out as when in a certain position or movement the power to the load side terminal would cease. Replaced the fault device and operated the Christmas lights and garage door to verify the issue resolved.
Arrived on the job site and the customer stated that two outlets on the garage/outdoor circuit were not working. I inspected the GFCI and found it in critical condition. The low side showed blue and orange discoloration on the brass terminals, indicating overheating or a loose connection causing arcing. I replaced the GFCI and also noticed that one of the lines had not been connected, so I reconnected it properly. After reinstalling everything and restoring power, all outlets were working correctly. I also observed that the customer has several items on this circuit, including Christmas lights and a freezer, but none of them are overloading the circuit at this time. The customer understands that the new GFCI outlet comes with a five-year warranty and is 100% satisfied with today’s visit.
Preform camera diagnostic on drainage system under home, and sewer line in yard. - check accessible piping for any issues or deficiencies ** any issues found will be brought up and explained in detail along with solutions on issues ** Found belly in line between 48 and 65 ft Supervisor will be leaving estimate for customer
- Run cable on hall bath tub due to standing water. - if there are bigger issues then we will discuss further investigation - Successfully got tub to drain , tested multiple times. Customer watched the whole time and is satisfied He didn’t want overflow plate put back as he’s going to get new hardware No warranty on drain clears
Run dedicated circuits in garage for refrigerator and power tools
Replace circuit breaker, install junction box, install oven outlet
Install 50 amp outlet for oven, replace circuit breaker, install weatherproof, main breaker panel, install grounding system, install hardwired, smoke detectors, install whole home surge protection
Added interlock kit with inlet for generator also added ground rod for panel.
Replace panel and service properly ground home
Re located 200 amp panel from closet to outdoor replaced meter base added 2 ground rods one cold water bond. Added surge protection added generator inlet
It’s all customer supplied ceiling, fan and move electricity around the room
Installed new 240v 3-Wire Dryer Cord and 240v 30amp Receptacle With 5 year Warranty On All Parts And Labor