Very professional and pleasant

Hector was very professional and took care of the electrical issues in our hone.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great

Service was great. Knowledge was great. Demeanor was great. Totally satisfied

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for mansfield, tx

Hector G.

Hector G. Job Checkin

Installed bulbs on all fixtures in kitchen except for one that we did not receive will be getting installed next week Friday the 21st ran wire from outlet to transformer with Sheetrock damage which customer was aware of ran wire from transformer up to doorbell and installed doorbell tested voltage and doorbell powered on customer just needs to set everything from doorbell to plug in chime on her app did not charge for doorbell to insure customer satisfaction customer was 100% happy and satisfied with todays service.

Installed bulbs on all fixtures in kitchen except for one that we did not receive will be getting installed next week Friday the 21st ran wire from outlet to transformer with Sheetrock damage which customer was aware of ran wire from transformer up to doorbell and installed doorbell tested voltage and doorbell powered on customer just needs to set everything from doorbell to plug in chime on her app did not charge for doorbell to insure customer satisfaction customer was 100% happy and satisfied with todays service. Installed bulbs on all fixtures in kitchen except for one that we did not receive will be getting installed next week Friday the 21st ran wire from outlet to transformer with Sheetrock damage which customer was aware of ran wire from transformer up to doorbell and installed doorbell tested voltage and doorbell powered on customer just needs to set everything from doorbell to plug in chime on her app did not charge for doorbell to insure customer satisfaction customer was 100% happy and satisfied with todays service.

James A.

James A. Job Checkin

Performed camera inspection in order to locate cleanouts in front yard. As a courtesy also dug up area with cleanouts to expose them. Per customers request I did not fill the dirt back in that was removed. Job complete.


James A.

James A. Job Checkin

.

.

Alex C.

Alex C. Job Checkin

Arrived on site. The customer stated that multiple outlets in the restroom, kitchen, and outdoor areas were not working. Performed a troubleshooting inspection to diagnose the issue. Upon opening the panel cover, I noticed significant heat damage, discoloration, and several melted wires. I informed the customer that the panel was in poor condition and needed to be replaced. Provided a detailed solution that includes:     •    Replacing the main breaker panel in the garage (lifetime warranty)     •    Replacing the meter base on the exterior wall (lifetime warranty)     •    Installing a surge protector rated for 108,000 amps with a lifetime warranty     •    Installing a 200-amp service disconnect by the meter base (lifetime warranty)     •    Pulling a city permit and inspection to ensure all work meets current electrical code     •    Replacing all hardwired smoke detectors with 10-year units (10-year warranty)     •    Adding a GFCI outlet at the wet bar     •    Troubleshooting ou

Arrived on site. The customer stated that multiple outlets in the restroom, kitchen, and outdoor areas were not working. Performed a troubleshooting inspection to diagnose the issue. Upon opening the panel cover, I noticed significant heat damage, discoloration, and several melted wires. I informed the customer that the panel was in poor condition and needed to be replaced.

Provided a detailed solution that includes:
    •    Replacing the main breaker panel in the garage (lifetime warranty)
    •    Replacing the meter base on the exterior wall (lifetime warranty)
    •    Installing a surge protector rated for 108,000 amps with a lifetime warranty
    •    Installing a 200-amp service disconnect by the meter base (lifetime warranty)
    •    Pulling a city permit and inspection to ensure all work meets current electrical code
    •    Replacing all hardwired smoke detectors with 10-year units (10-year warranty)
    •    Adding a GFCI outlet at the wet bar
    •    Troubleshooting ou Arrived on site. The customer stated that multiple outlets in the restroom, kitchen, and outdoor areas were not working. Performed a troubleshooting inspection to diagnose the issue. Upon opening the panel cover, I noticed significant heat damage, discoloration, and several melted wires. I informed the customer that the panel was in poor condition and needed to be replaced.

Provided a detailed solution that includes:
    •    Replacing the main breaker panel in the garage (lifetime warranty)
    •    Replacing the meter base on the exterior wall (lifetime warranty)
    •    Installing a surge protector rated for 108,000 amps with a lifetime warranty
    •    Installing a 200-amp service disconnect by the meter base (lifetime warranty)
    •    Pulling a city permit and inspection to ensure all work meets current electrical code
    •    Replacing all hardwired smoke detectors with 10-year units (10-year warranty)
    •    Adding a GFCI outlet at the wet bar
    •    Troubleshooting ou

Johnathan P.

Johnathan P. Job Checkin

Customer called us out for main drain back up, tested drainage from inside the house. It was draining good. Customer stated it happened when the backwash was on for the pool so we tried the backwash. The pipe was not perfectly lined up, so it spits out on the side a little bit. ( No issue ) Did perform complementary safety inspection found a couple of issues such as high water pressure and a tankless maintenance. Gave estimates customer is not proceeding with work currently.

Customer called us out for main drain back up, tested drainage from inside the house. It was draining good. Customer stated it happened when the backwash was on for the pool so we tried the backwash. The pipe was not perfectly lined up, so it spits out on the side a little bit.

( No issue )

Did perform complementary safety inspection found a couple of issues such as high water pressure and a tankless maintenance.

Gave estimates customer is not proceeding with work currently. Customer called us out for main drain back up, tested drainage from inside the house. It was draining good. Customer stated it happened when the backwash was on for the pool so we tried the backwash. The pipe was not perfectly lined up, so it spits out on the side a little bit.

( No issue )

Did perform complementary safety inspection found a couple of issues such as high water pressure and a tankless maintenance.

Gave estimates customer is not proceeding with work currently.

Tyler B.

Tyler B. Job Checkin

Installed ceiling fan in back bedroom.

Installed ceiling fan in back bedroom. Installed ceiling fan in back bedroom.

Tyler B.

Tyler B. Job Checkin

Replace dishwasher breaker Replaced faulty dual function breaker for dishwasher

Replace dishwasher breaker 

Replaced faulty dual function breaker for dishwasher Replace dishwasher breaker 

Replaced faulty dual function breaker for dishwasher

Alex C.

Alex C. Job Checkin

Arrived to install two fandeliers and replace a led can trim. Removed the broken trim and installed a new color selectable trim to match with the existing lighting. Over the dining table removed the existing chandelier and installed a fan brace box as the new fixtures have crystal on them. Also installed a box and fandelier in the master bedroom. Cleaned work areas and made sure everything was operational.

Arrived to install two fandeliers and replace a led can trim. Removed the broken trim and installed a new color selectable trim to match with the existing lighting. Over the dining table removed the existing chandelier and installed a fan brace box as the new fixtures have crystal on them. Also installed a box and fandelier in the master bedroom. Cleaned work areas and made sure everything was operational. Arrived to install two fandeliers and replace a led can trim. Removed the broken trim and installed a new color selectable trim to match with the existing lighting. Over the dining table removed the existing chandelier and installed a fan brace box as the new fixtures have crystal on them. Also installed a box and fandelier in the master bedroom. Cleaned work areas and made sure everything was operational.

Alex C.

Alex C. Job Checkin

Installed new range outlet


Marco B.

Marco B. Job Checkin

Troubleshoot and repair power loss to bathroom outlets, install whole home surge protection, hardwire appliance, replace circuit breakers, install switches and outlets


Hector G.

Hector G. Job Checkin

Replaced outlet


Blake L.

Blake L. Job Checkin

Replace electrical panel, meter base, disconnect, grounding system, surge protection, replacing plugs and switches, arc fault breakers, standard breakers, upgrading service, troubleshooting


Hector G.

Hector G. Job Checkin

Replaced bad gfci


Johnathan P.

Johnathan P. Job Checkin

Toilet replacement


Johnathan P.

Johnathan P. Job Checkin

Disposal replacement