8108 Commercial Street
La Mesa, CA 91942
619-464-5625

Local Reviews
for santee, ca

Rated 4.8 out of 5 stars based on 6 customer reviews

Community Manager

  • Overall Experience
  • Quality
  • Price
  • Convenience

Good Service, Knowledgeable Service Men

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service, explained everything

On time and started immediately. Good person to follow.

  • Overall Experience
  • Quality
  • Price
  • Convenience

We LIke Brian!!!

We like that Brain is knowledgeable and provides us with detailed information on what he is doing and on any thing that needs attention. He is professional and thorough. THANKS BRIAN!!!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Knowledgable and

They are very responsive, professional and cost effective. They offer all the services you need for fire and life safety. I definitely would recommend this company to other Property managers in my company for a reliable fire protection service.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent service!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for santee, ca

Cody T.

Cody T. Job Checkin

Provide labor and material to correct the deficiencies verified during the recent inspection: AFS Inclusions: Replace Miscellaneous Fire Sprinkler Control signs throughout the property Replace (4) fire sprinkler head cover plates Qualifications: Per CCR Title 19 Section 906.4(a), deficiencies are required to be reported to the local fire authority upon discovery. AFS will provide a 30 day grace period, from date of notification, in good faith that the repairs will be completed by the customer. Customer Responsibilities: Move EXIT lights causing fire sprinkler obstruction, fire sprinklers must have a minimum of 18" clearance to the deflector Sprinkler Repair Backflow missing FDC sign - repair Repair of Obstruction by exit sign on second floor hallway. Near by unit 203 Repair of Missing cover plate unit 306 building 9550 Repair of Painted cover plate. Building 9550, second floor hallway by unit 201 Repair of Obstruction of exit light, first and second floor hallway, building 9540


Cody T.

Cody T. Job Checkin

Portable Extinguishers Inspection Annual Fire Extinguisher Inspection


Austin B.

Austin B. Job Checkin


Angel A.

Angel A. Job Checkin

Annual Fire Alarm Inspection Wet Right corner: Annual Fire Sprinkler Inspection


Angel A.

Angel A. Job Checkin

Annual Fire Alarm Inspection


Angel A.

Angel A. Job Checkin

Annual Fire Alarm Inspection Annual Fire Extinguisher Inspection


Cody T.

Cody T. Job Checkin

Sprinkler Inspection Annual Fire Sprinkler Inspection Deficiency: (1) 155 degree standard response brass pendant, inside server room (1) 155 degree standard response brass pendant, inside office next to anice Pilkaytis, inside the small closest. (1) 155 degree standard response brass pendant, inside anice Plikaytis office (1) 155 degree Tyco 3251 chrome pendant, inside Leigh Powell office (1) Missing escutcheon chrome 401, inside office next to Troy Smith office. (1) 155 degree Tyco 3251 chrome pendant, inside upstairs office in the back. Suggested to add more spare heads inside spare head box


Angel A.

Angel A. Job Checkin

Annual Fire Alarm Inspection


David A.

David A. Job Checkin


Brian P.

Brian P. Job Checkin


Brian P.

Brian P. Job Checkin


Brian P.

Brian P. Job Checkin


David A.

David A. Job Checkin

Sprinkler Inspection


Cody T.

Cody T. Job Checkin


David A.

David A. Job Checkin

5 Year Sprinkler Inspection