Rated 5.0 out of 5 stars based on 2 customer reviews

Excellent Sevice

Confires Technician George was Excellent. George was courteous, knowledgeable and willing to answer all my questions. His technical ability is obviously second to none. He is serious and passionate about his job and executes tasks accordingly. Upon completion, he leaves the work area spotless and free of any debris. I would highly recommend him to anyone who needs this type of fire service.

  • Overall Experience
  • Quality
  • Convenience
  • Recommend

Professional

  • Overall Experience
  • Quality
  • Convenience
  • Recommend

Job Locations
for carlstadt, nj

George W.

George W. Job Checkin

Put system into service. Scheduled with Lupo 551-697-5094


George W.

George W. Job Checkin

COD $883.92 Scheduled with Lupo 551-697-5094 The following discrepancies were found during your Semi Annual Fire Inspection that needs to be corrected for Compliance: Improper nozzle placement in plenum. Need to move 1 nozzle to end of hood. Need to remove pyro chem hangers from link housings and replace with s hooks and crimps. Need to add micro switch to control head to connect to building alarm. Alarm company needs to add audible- visual device to kitchen. (Confires will supply Horn strobe) Range nozzles obstructed by shelves. (Customer to remove shelves)


George W.

George W. Job Checkin

CALL WHEN YOU ARE IN ROUTE **COD- Call Regina to get CC///**Regina/-212-431-2790 financial controller for cc info Confirmed with: Neal 610-573-9081 Annual Extinguisher Inspection (7) 1-10lb co2 hydro


George W.

George W. Job Checkin

COD 301.43 AFTER INSPECTION THEY NEED YOU TO DISARM SYSTEM AND MOVE FOR CONSTRUCTION Semiannual Kitchen Inspection Scheduled with Lupo (Tommys Cousin) 551-697-5097


Bob H.

Bob H. Job Checkin


George W.

George W. Job Checkin

PERMIT #20250021 COD - collect $2857.50 plus $560.00 for todays final inspection. Total $3,417.50 Township #201-939-1777 Final Inspection. Need to bring PVA for one cylinder when we return for final. Inspection time frame: 7-9am


George W.

George W. Job Checkin

Scheduled with Ricky 917-715-7101 Project scope to include: Engineering Pre-Engineered drawings and permit submittal   Ansul/Pyro equipment PCl35ABC Agent Cylinder bracket Mechanical control head w/ micro switch Cable pull station (1) 120vac horn/strobe (2) fusible link (212) detectors (1) N-ABC Nozzle w/Cap   Misc pipe and fittings Labor to install above Labor to conduct "Final" Air test to close out permit


Sean W.

Sean W. Job Checkin


Mike  P.

Mike P. Job Checkin


Mike  P.

Mike P. Job Checkin


Mike  P.

Mike P. Job Checkin


Kyle  R.

Kyle R. Job Checkin

Sprinkler and Backflow Inspection


Patrick B.

Patrick B. Job Checkin


Kossi A.

Kossi A. Job Checkin


Kossi A.

Kossi A. Job Checkin