My experience with George was outstanding. George described exactly what he needed to do and why. I enjoy working with a caring employee that cares about his customers. Thank you, George.
Kossi was very professional and friendly! Called ahead. Testing was quick and accurate!
The service he provided to our Elks lodge was great. Would recommend him to anybody.
Permit 25-112 Final Inspection System needs connected to building alarm and horn strobe installed.
COD $2024.06 FRANK TO HELP GEORGE HANG THE CYLINDER Scheduled with Jairo 908-887-6109 Furnish necessary parts and labor to complete the following repairs per manufacture specifications and code requirements: -- Upgrade the system cylinder to a BFR-20 system to account for needed flows to properly protect all appliances -- Install protection over the griddle and cheese Melter due to both appliances currently having no protection
Scheduled with Luppy 908-452-5599 The following discrepancies were found during your Semi Annual Fire Inspection that needs to be corrected for Compliance: Customer added griddle to cooking line. Griddle lacks protection. Will need need to add additional detection and adjust position of detection above fryer. Need to adjust position nozzle above Range. NOT INCLUDED IN THE PRICING OF THIS QUOTE: • Permit (If applicable. Pricing TBD by township upon issuance of permit) • NJ Sales Tax • Engineered Drawings (If applicable)
Semiannual Kitchen Inspection Scheduled with Svetlanna - Management (908) 979-8998
Scheduled with Beth 201-919-8399 Ask Randy if the electrician needs to be there the same day. The following discrepancies were found during your Semi Annual Fire Inspection that needs to be corrected for Compliance: Cheese melter lacks protection, electric griddle failed to shut off upon system activation, and incorrect nozzles over Range and griddle due to back shelf. Pre UL 300 system. System will need to be upgraded. SCOPE OF WORK: Furnish necessary parts and labor to upgrade existing system to a UL300 compliant 260 gal Range Guard system. ***NOTE*** FINAL INSPECTION WITH TOWNSHIP IS INCLUDED IN THE PRICING BUT WILL BE BILLED SEPARATLEY ***NOTE*** CUSTOMER WILL NEED TO HIRE AN ELECTRICIAN TO ADDRESS ANY ELECTRICAL WORK.
Semiannual Kitchen Inspection Scheduled with Patrick 973-747-7599
Semiannual Kitchen Inspection Annual Fire Extingusiher Inspection Scheduled with Heddy 917-359-7689
THEY HAVE A NEW APPLIANCE, SEE IF YOU CAN MAKE NEEDED ADJUSTMENT ON SITE AT TIME OF INSPECTION AND LET CAILEY KNOW Semiannual Kitchen Inspection Scheduled with Jordan 908-850-0224 Ext 102
Call when you are on your way. Semiannual Kitchen Inspection Scheduled with Pedro 213-948-7963 Arrival: 8-11am
Semiannual Kitchen Inspection Annual Fire Extinguisher Inspection Scheduled with Svetlanna - Management (908) 979-8998