2710 Northridge Dr. Suite #F
Grand Rapids, MI 49544
1-800-968-2871

Our Top Cities


Local Reviews

Rated 4.9 out of 5 stars based on 1835 customer reviews

Annual Inspection

He was very through on making sure that everything was up to par.

  • Overall Experience
  • Quality
  • Price
  • Convenience

informative and efficient

would recommend to others

  • Overall Experience
  • Quality
  • Price
  • Convenience

Very nice and professional service men

The technicians are always so friendly and let me know each and everything they are going to test before they do the test.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent

Very friendly and knowledgeable

  • Overall Experience
  • Quality
  • Price
  • Convenience

St. Anns. Senior Center Kitchen Supervisor

He was quick and very professional.

  • Overall Experience
  • Quality
  • Price
  • Convenience

service

  • Overall Experience
  • Quality
  • Price
  • Convenience

Friendly techs, but not on time and took longer than expected.

Tech showed up 2 hours after appointment time and caused me to stay after work about 2.5 hours because the job also took longer than estimated.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great

Very fast response

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service

Sean did a good job. He should bring donuts the next time. lol

  • Overall Experience
  • Quality
  • Price
  • Convenience

Thank yoi

Always professional

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations

Alex R.

Alex R. Job Checkin

Completed Emergency Sprinkler Service Call


Alex R.

Alex R. Job Checkin

1)Replaced Inner Front Door Key Pad Completely (New Key Pad, New Wire Harnesses and Used New Static Shock Wiring Harness. Re-Wired, Programmed and Tested Key Pad. *** All systems Normal and Reset *** 2)Replaced Foyer Vestibule Key Pad Mother Board and Installed Static Shock Wire Harness. Programmed and Tested ***All systems Normal and Reset *** 3)Replaced Door Contact on Inner Front Door. Wired and tested.


Camp M.

Camp M. Job Checkin

Repaired the horn strobe by the technology room exit door.


David H.

David H. Job Checkin


Austin C.

Austin C. Job Checkin


Brandon  F.

Brandon F. Job Checkin


Art L.

Art L. Job Checkin

Fire Door Service Call


Russ F.

Russ F. Job Checkin

Wet Basement storage: Install the missing Inspection Test Valve sign and provide proper identification. Valve identification is beneficial in at least three ways. It allows the fire department personnel to locate and operate the valve. A contractor can readily shut off the system to make modifications. And system valves can be easily identified during periodic inspections. NFPA 13 (6.7.4.1) All control, drain, and test connection valves shall be provided with permanently marked weatherproof metal or rigid plastic identification signs. Wet Basement storage: Remove and replace the outdated water gauge. Pressure surges are typically trapped in the system by the check valve. Readings from these gauges can be used to establish a database on the available pressure in the water supply. The gauge on the supply side is also used during the main drain test to establish a database of residual pressure in the water supply. NFPA 13 (8.17.3) & NFPA 25 (13.2.7.2) Gauges shall be replaced every 5 yea


Camp M.

Camp M. Job Checkin

Installed new cellular communicator.


Brandon  F.

Brandon F. Job Checkin


Alex R.

Alex R. Job Checkin

Completed Annual Fire Alarm Inspection for 2019


Brandon  F.

Brandon F. Job Checkin


Tyler H.

Tyler H. Job Checkin

back plate is rusting on smoke detector that I just programmed the head for Point 19. I showed Demonte the rust forming,there will be issues in the near future with 19. I suggest it's replaced before troubles arise. customer had water damage in the area - repair


Mike R.

Mike R. Job Checkin

Annual Fire Alarm System Inspection


Alex R.

Alex R. Job Checkin

New 12 volt Power Supply Installed 1-17-19 ALR For Interior Key Pads ***All systems Normal and Reset ***