2710 Northridge Dr. Suite #F
Grand Rapids, MI 49544
1-800-968-2871

Our Top Cities


Local Reviews
for elkhart, in

Rated 4.8 out of 5 stars based on 4 customer reviews

Professional attutied

Called before showing up Professional attitude Preformed service an explained that next yr. will be a test.


Response from Fire Pros, LLC:

Thank you for leaving a review, we greatly appreciate your feedback! Chris is an awesome asset and we want to create value for you and your organization, Thanks again and have a fire safe day! Also if you have time, please visit Google and leave us a review there as well, we would greatly appreciate it!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Office Manager

Eric was very professional and friendly

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service

Faster better service than my previous service company

  • Overall Experience
  • Quality
  • Price
  • Convenience

good service

The tech was professional and thorough in his inspection.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for elkhart, in

Tyler H.

Tyler H. Job Checkin

Annual Fire Alarm System Inspection Annual Fire Extinguisher Inspection


Mike R.

Mike R. Job Checkin

FACP shows Room 207 missing.Sounder bass had it appears, a screwdriver jammed in the Paizo and a broken wire probably, from the same screwdriver. Smoke head was also very dirty. CleanedSmoke detector head and replaced in room 207 was still missing. Took detector apart to get down to bass and saw damage. Not sure if damage is contained to bass or if head and base plate are also damaged. Model numbers for all in deficiency attachments. Need to order new parts and return to repair. This is nothing we should send to maintenance to complete. - repair


Mike R.

Mike R. Job Checkin

Deficiency: FACP shows Room 207 missing.Sounder bass had it appears, a screwdriver jammed in the Paizo and a broken wire probably, from the same screwdriver. Smoke head was also very dirty. CleanedSmoke detector head and replaced in room 207 was still missing. Took detector apart to get down to bass and saw damage. Not sure if damage is contained to bass or if head and base plate are also damaged. Model numbers for all in deficiency attachments. Need to order new parts and return to repair. This is nothing we should send to maintenance to complete.


Tyler H.

Tyler H. Job Checkin

Per Jeremy smoke in room 305 is broken and needs to be replaced


Mike R.

Mike R. Job Checkin

Annual Fire Alarm System Inspection


Mike R.

Mike R. Job Checkin

Annual Fire Alarm System Inspection


Chris P.

Chris P. Job Checkin


ERIC H.

ERIC H. Job Checkin


ERIC H.

ERIC H. Job Checkin


ERIC H.

ERIC H. Job Checkin


ERIC H.

ERIC H. Job Checkin


ERIC H.

ERIC H. Job Checkin


ERIC H.

ERIC H. Job Checkin


ERIC H.

ERIC H. Job Checkin


ERIC H.

ERIC H. Job Checkin