2710 Northridge Dr. Suite #F
Grand Rapids, MI 49544
1-800-968-2871

Our Top Cities


Local Reviews
for auburn hills, mi

Rated 4.7 out of 5 stars based on 13 customer reviews

Good service

TJ was great to work with and answered all questions. Arrived on time and made sure we were satisfied with the job before he left.

  • Overall Experience
  • Quality
  • Convenience
  • Recommend

Great service

Technician was on time, knowledgeable and performed the work as outlined.

  • Overall Experience
  • Quality
  • Convenience
  • Recommend

Great work, awesome attention to detail

Work was conduction quickly and accurately. I appreciated their feedback.

  • Overall Experience
  • Quality
  • Convenience
  • Recommend

Job well done

  • Overall Experience
  • Quality
  • Convenience
  • Recommend

Poor service , unprofessional

Very very unprofessional. Came in when we opened and threw his stuff on our counter , he stepped on our grill with his shoes and it was gross. Asked for a free sub at the end .

  • Overall Experience
  • Quality
  • Convenience
  • Recommend

Great Job

Great Fast accurate Service

  • Overall Experience
  • Quality
  • Convenience
  • Recommend

Good Job

  • Overall Experience
  • Quality
  • Convenience
  • Recommend

Good Job

  • Overall Experience
  • Quality
  • Convenience
  • Recommend

Excellent Service and Care

I have been with my company for over a year now, and have had a lot of companies do service and different things to our building/machines. We believe in a correct way, an aesthetic way, and a safe way. We appreciate when Fire Systems of Michigan comes because they handle our building like its their own. Jered is an outstanding professional service tech. Thank you

  • Overall Experience
  • Quality
  • Price
  • Convenience

Annual Inspection

Gerald did job today doing the inspection.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great working with Fire Pros!

We have always had good service from Fire Pros. Your representatives are knowledgeable, friendly and thorough. Thanks

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great Service

Matt was extremely professional and handled the inspection in a timely fashion.

  • Overall Experience
  • Quality
  • Price
  • Convenience

food line leader

very informative.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for auburn hills, mi

Terrence  J.

Terrence J. Job Checkin

Must have safety glasses and high vis vest in shop. Also will need key for lock on WPIVs Will also need 2nd floor janitors closet unlocked to access ITV Sprinkler Repair Wall PIV tamper failed to operate and open closed indicator needs to be adjusted. The tech will troubleshoot the switch. Inoperable Deficiency: The tamper switch that I was sent out to adjust has a wiring problem that must be addressed by the fire alarm division the tamper switch manually trips, but does nothing in the system. All the wiring is on the open and close, but there are no wires on the common. I’m not sure if this is correct or not. 1- fire alarm technician to correct problem


Terrence  J.

Terrence J. Job Checkin


Sean W.

Sean W. Job Checkin


James J.

James J. Job Checkin


James J.

James J. Job Checkin


George S.

George S. Job Checkin


James J.

James J. Job Checkin


George S.

George S. Job Checkin


Robert G.

Robert G. Job Checkin


Robert G.

Robert G. Job Checkin


John  R.

John R. Job Checkin


George S.

George S. Job Checkin


Terrence  J.

Terrence J. Job Checkin

11/6/23 Material in shop in Novi if needed. DH 10/30/23 Confirmed by Keith Tillman for 11/8/23 at 8:00am DH / Sent email regarding inspection DH Hydrostatic Testing, Sprinkler, and Obstruction Investigation Repair The FDC is due for its 5-year hydro-static testing. The tech will perform this test on the Fire Department Connection (FDC). NFPA 25 (13.8.5) The piping from the fire department connection to the fire department connection check valve shall be hydro-statically tested at 150psi (10 bar) for 2 hours at least once every 5 years. The tech will remove and replace the outdated water gauges. NFPA 25 (13.2.7.2) Gauges shall be replaced every 5 years The systems check valve is due for its 5-year internal inspection. The tech will open the valves and verify there is no debris or damage that can prevent the valve from operating as designed. NFPA 25 (13.4.1.2) Alarm valves and their associated strainers, filters, and restrictions orifices shall be inspected internally every 5 yea


George S.

George S. Job Checkin


George S.

George S. Job Checkin