5/31/23 Confirmed with Jay for 6/5/23 at 9:00amish DH The dry pendents in the garage are due for testing because they have been in service for 10 years. Approval of replacement will consist of two steps: obtaining the sprinkler heads' measurements. Once the measurements are received, the next step would be to send a quote with the replacements' total cost. NOTE: Cutting the ceiling to obtain measurements is required. A sprinkler head in the end of the unit needs to be plugged.
Sprinkler Repair Control valves are not supervised. The tech will add the missing supervision to these valves. Sprinkler heads are missing from the spare headbox. The tech will add the missing heads. Deficiency: Improper amount of spare heads 2- ½" 155 qr chrome hsw Deficiency: Control valves missing supervision 3- braided cable 2- crimps 1- lock
Sprinkler Repair The dry pendents in the garage are due for testing because they have been in service for 10 years. Approval of replacement will consist of two steps: obtaining the sprinkler heads' measurements. Once the measurements are received, the next step would be to send a quote with the replacements' total cost. NOTE: Cutting the ceiling to obtain measurements is required. The fire sprinkler system control valve is not monitored. The tech will add supervision of the valve. This will prevent tampering with. NFPA 25 (13.3.1.3) Each normally open valve shall be secured utilizing a seal or a lock or shall be electrically supervised in accordance with applicable NFPA standards.
Sprinkler Repair The dry pendents in the garage are due for testing because they have been in service for 10 years. Approval of replacement will consist of two steps: obtaining the sprinkler heads' measurements. Once the measurements are received, the next step would be to send a quote with the replacements' total cost. NOTE: Cutting the ceiling to obtain measurements is required. Deficiency: Sprinkler head in the garage was found to be a 12 inch dry pendant that needs to be pulled
6/2/23 Sent Rick an email regarding the inspection. DH 5/22/23MV Emailed Tony regarding inspection date 5/31 Sprinkler Inspection Annual Sprinkler Inspection Deficiency: System is due for five-year internal obstruction investigation Deficiency: Sprinkler system is due for five-year gauge change. 1- gauge Deficiency: Main drain valve handle must be replaced it is broken. One valve handle for 2 inch angle valve Deficiency: Sprinkler system is due for five year internal check valve inspection and fire department connection Deficiency: Sprinkler system is due for Hydro test on fire department connection Deficiency: Dry pending heads are due for testing. Three 155° chrome pendant 12 inch in length standard response dry pendant sprinkler heads.
Sprinkler Repair The dry pendents in the garage are due for testing because they have been in service for 10 years. Approval of replacement will consist of two steps: obtaining the sprinkler heads' measurements. Once the measurements are received, the next step would be to send a quote with the replacements' total cost. NOTE: Cutting the ceiling to obtain measurements is required.
Sprinkler Repair The dry pendents in the garage are due for testing because they have been in service for 10 years. Approval of replacement will consist of two steps: obtaining the sprinkler heads' measurements. Once the measurements are received, the next step would be to send a quote with the replacements' total cost. NOTE: Cutting the ceiling to obtain measurements is required. The fire sprinkler system control valve is not monitored. The tech will add supervision of the valve. This will prevent tampering with. NFPA 25 (13.3.1.3) Each normally open valve shall be secured utilizing a seal or a lock or shall be electrically supervised in accordance with applicable NFPA standards. Deficiency: Dry pendants due for testing ( garage) Access required to get measurements Deficiency: Control valves need supervision 2- locks 4- crimps 4' braided cable