All of the gentlemen that I dealt with during the quote for service, the inspection process and the technicians that performed the service and repairs, were very professional. I look forward to using their services for our yearly inspections.
My walk through our fire system with TJ (service technician) was very thorough. He pointed out items that need to be addressed. TJ did this inspection in very professional manor.
Jim gave a great overview of fire extinguisher re-certification frequency including hydro testing etc
Jared with Fire Pros has always done a great job for us. 100% recommend
I was late getting into the building, but the tech was able to enter with another group and knew where everything was and conducted the inspection before I arrived. We appreciate his timely work and and letting me know there were no issues.
Very thorough and done quickly. Explained what he was doing and kept it clean.
Tech was very prompt and professional, great company all the way around, no complaints
5/22/23 Confirmed with Frank D. for 5/23/23 at 11:30amish DH / Sent email regarding inspection DH Sprinkler Inspection Annual Fire Sprinkler System Inspection Deficiency: Sprinkler system is due for gauge change. 1- gauge Deficiency: Fire department connection check valve due for five-year internal inspection. 2- Victaulic couplings 4” Deficiency: Sprinkler system is due for five year internal obstruction investigation. 2 - 4” Victaulic couplings Deficiency: Sprinkler system fire department connection due for five year Hydro test. Deficiency: The sprinkler system has three rollup doors next to riser that have no protection under the doors these doors will have to be protected so that they are covered under NFPA fire code. it is possible that the city of Lavonia will require a permit for this work we must clear with the city how they will want us to proceed and then we can measure and fabricate piping according to specs that they lay out.
Sprinkler Inspection 5/2/23MV Emailed Corey and David regarding inspection date 5/11, David confirmed Annual Fire Sprinkler Inspection (2 Wet Systems) Deficiency: Brian would like the overhead door protection to be adjusted. We will be removing both upright pendants from the east side overhead doors and installing a single sidewall for each. Parts needed 2 - 1” X 1/2” reducing coupling threaded 2 - 1/2” brass 155 sidewall SR 2 - 1/2” sidewall head guards 2 - 1” threaded plugs 2 - 0’6” nipples There is a hi-lo basket on-site that reaches the area needed to perform the work. Deficiency: Arrived on site and after talking to Brian he showed us where the noise was coming from. The noise is coming from the 8” heresy swing check that is being used as the backflow. Brian said that the noise hasn’t happened since they turned off the yard sprinklers. With that being said it’s to believe that the spring tension is bad and any time water moves it’s causing the check to open and close old check
4/26/23 Confirmed with Trinity 313-600-0696 for 5/2/23 at 10:15am. DH Please call Trinity when enroute. Sprinkler Inspection Annual Fire Sprinkler Inspection Deficiency: There is no evidence of five-year internal inspection of check valves on system. Deficiency: Sprinkler heads in sprinkler head box will have to be replaced they are over 50 years old. Deficiency: There is no evidence of five-year Hydro test on fire department connection. Deficiency: There is no evidence of five-year internal inspection of check valves on system. Deficiency: Five year internal obstruction investigation is not evident on this sprinkler system and must be performed. Deficiency: Fire sprinkler system will need gauge change Deficiency: Outside bell 🔔 inoperable. 10 inch bell as well as electrical Tie ins will have to be performed on this bell
4/21/23 Material in shop in Novi DH Sprinkler Repair A tech responded to a service call on 3/27/23 for the air compressor running more than normal. The tech noted that the pressure switch on the compressor is damaged and causing the compressor to run too much. The tech will remove and replace the switch. Deficiency: Small brass pressure relief for a compressor keeps popping at about 110 psi this item may be bad and should probably be replaced
4/4/23 Confirmed with Bob M. for 4/5/23 around 11:30am DH / Sent email regarding inspection DH Sprinkler Inspection Annual Sprinkler Inspection Deficiency: Missing spare sprinkler head box. 2- 1/2” sidewall 155 degree S.R. Chrome. 4- 1/2” pendant 155 degree S.R. Chrome. Standard head wrench. Deficiency: Missing spare sprinkler head box. 2- 1/2” sidewall 155 degree S.R. Chrome. 4- 1/2” pendant 155 degree S.R. Chrome. Standard head wrench.