Rated 5.0 out of 5 stars based on 3 customer reviews

Great

Mike is awesome to work with and I appreciate his passion.

  • Overall Experience
  • Quality
  • Convenience
  • Recommend

Prompt courteous service

Your employee was on time and carried out the inspection needs in a very professional manner.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great Service. We called and the tech was here within a hour

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for marne, mi

Art L.

Art L. Job Checkin

Annual Fire Extinguisher Inspection (16 FE)


Art L.

Art L. Job Checkin

Portable Extinguishers Inspection


Mike R.

Mike R. Job Checkin

check panel per Gregg after power fail.


Mike R.

Mike R. Job Checkin

Suggested: I removed sd by room 329 point 83. Smoke head was cleaned but went back in and out of trouble. Going to remove head for a while see if rest of system shakes out. While on site I ran into a gentleman from Pioneer construction. In speaking with him I was informed in and around March if things go well they will be doing an interior remodel. Alec We would like to be kept in the loop and have early notice if possible so that we may do a preventative maintenance type deal as they are doing demolition. This way we can preserve the integrity of the devices and not have to replace them. Thank you sir and, have a great weekend. Tech note: Supervision voltage on SLC at detector base and panel varies but never goes below 19 V.


Mike R.

Mike R. Job Checkin

DD EAST BLDG | 2ND FL NORTH MECH ROOM 710: Point #94 DD in mechanical room 710 has been in runaway trouble mode. Removed head to change state of the point to no answer so it can’t go in an out of trouble. DD head will be quoted and then replaced - repair 2 smoke heads and 1 base plate need to be quoted. 2 -Faraday 8710 smoke heads and 1-- 8853 base . - repair


Mike R.

Mike R. Job Checkin

Deficiency for DD EAST BLDG | 2ND FL NORTH MECH ROOM 710: Point #94 DD in mechanical room 710 has been in runaway trouble mode. Removed head to change state of the point to no answer so it can’t go in an out of trouble. DD head will be quoted and then replaced


Mike R.

Mike R. Job Checkin

Suggested: 2 smoke heads and 1 base plate need to be ordered and replaced.


John  R.

John R. Job Checkin


Mike R.

Mike R. Job Checkin

Alec called in, needs someone out to check the alarm system- he just received a call from CMS - received a power fail and many troubles. key box entry. call Alec with findings - 616-583-9820 KEY BOX code is 420.


Ron  R.

Ron R. Job Checkin


John  R.

John R. Job Checkin


Mike R.

Mike R. Job Checkin

Telgard cell radio is a 3G and is in constant failure. Signal strength fluctuates from .5 to 2.5 bars continuously.This radio should be upgraded to 4G LTE as soon as possible. I have an outside wall about 15 feet from radio. Also need a 25 foot outdoor cable with outdoor rated antenna. - repair


John  R.

John R. Job Checkin


Mike R.

Mike R. Job Checkin

Deficiency: Telgard cell radio is a 3G and is in constant failure. Signal strength fluctuates from .5 to 2.5 bars continuously.This radio should be upgraded to 4G LTE as soon as possible. I have an outside wall about 15 feet from radio. Also need a 25 foot outdoor cable with outdoor rated antenna.


Sean W.

Sean W. Job Checkin