2710 Northridge Dr. Suite #F
Grand Rapids, MI 49544
1-800-968-2871

Our Top Cities


Local Reviews
for novi, mi

Rated 5.0 out of 5 stars based on 6 customer reviews

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great Service

Sean is a pleasure to work with. He is very knowledgeable and willing to help you understand the system for trouble shooting problems that may occur with the sprinkler system.

  • Overall Experience
  • Quality
  • Price
  • Convenience

very professional

  • Overall Experience
  • Quality
  • Price
  • Convenience

Branch Manager

  • Overall Experience
  • Quality
  • Price
  • Convenience

Nice guys to work with

I like fire pros. The guys that come in know what they are doing but always seem to have fun while doing their job. It is enjoyable to work with them.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Very Professional, Friendly, and Great Service

I think your company is lucky to have such a great employee!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for novi, mi

Alex R.

Alex R. Job Checkin

Completed the required inspection of the smoke alarms in the tenant apartments.


Alex R.

Alex R. Job Checkin

FACP NORMAL UPON ARRIVAL, CHECKED ROOM 6 SMOKE ALARM, BATTERY GOOD, CHECKED WIRING FOUND FACP WIRING HARNESS CONNECTION WAS LOOSE CAUSING OPEN CKT TROUBLES ON FACP, RE-FASTENED WIRING AND TESTED UNIT. ***All Systems Normal and Reset ***


Alex R.

Alex R. Job Checkin

FACP NORMAL UPON ARRIVAL, CHECKED ROOM 6 SMOKE ALARM, BATTERY GOOD, CHECKED WIRING FOUND FACP WIRING HARNESS CONNECTION WAS LOOSE CAUSING OPEN CKT TROUBLES ON FACP, RE-FASTENED WIRING AND TESTED UNIT. ***All Systems Normal and Reset ***


Sean W.

Sean W. Job Checkin


Alex R.

Alex R. Job Checkin

Replaced 3rd Floor Hudson Park NAC PNL and Combo Smoke/CO Detector by 215 Edgewater and Tested ***All systems Normal and Reset ***


Alex R.

Alex R. Job Checkin

Replaced 3rd Floor Hudson Park NAC PNL and Combo Smoke/CO Detector by 215 Edgewater and Tested ***All systems Normal and Reset ***


Mike R.

Mike R. Job Checkin

Annual Alarm Inspection


Mike R.

Mike R. Job Checkin

James 248-579-3908 open nac circuit trouble laundry room


Alex R.

Alex R. Job Checkin

Replaced NAC Panel in Hudson Park and Tested. Also Tried Replacing Combo Smoke/CO detector but had incorrect part., And As for smoke detector in meadow brook square (It is not a smoke it is a hidden camera) Will have to return with correct part for edgewater and replace 1 more NAC PNL on third floor of Hudson Park and Test.


Christian L.

Christian L. Job Checkin


Jeff D.

Jeff D. Job Checkin

Annual Fire Extinguisher Inspection (2 FE) Annual Emergency/Exit Light Inspection (4 units) Semi-Annual Kitchen Suppression System Inspection


Alex R.

Alex R. Job Checkin

Replaced missing Pull cord in Room 27 Bedroom and Tested ***All systems Normal and Reset ***


Jeff D.

Jeff D. Job Checkin

Annual Fire Extinguisher Inspection


Alex R.

Alex R. Job Checkin

Completed Annual Nurse Call Inspection for 2019


Russ F.

Russ F. Job Checkin

Inoperable Deficiency: ITV is partially blocked by sediment inside pipe. Will need to tear apart and forcibly flush out, until clean Inoperable Deficiency: itv is clear of obstructions. Pipe was not in need of replacement, because it was not found to be leaking, but it was in need of a thorough cleaning.