2710 Northridge Dr. Suite #F
Grand Rapids, MI 49544
1-800-968-2871

Our Top Cities


Local Reviews
for portage, mi

Rated 4.9 out of 5 stars based on 32 customer reviews

Assistant Center Manager

Professional from start to finish.

  • Overall Experience
  • Quality
  • Convenience
  • Recommend

Maintenace manager

  • Overall Experience
  • Quality
  • Convenience
  • Recommend

Great Service

  • Overall Experience
  • Quality
  • Convenience
  • Recommend

Property Manager

  • Overall Experience
  • Quality
  • Convenience
  • Recommend

great service

Tyler was very professional, and very willing to answer any question I had.

  • Overall Experience
  • Quality
  • Convenience
  • Recommend

Miantenance Supervisor

Efficient and timely,

  • Overall Experience
  • Quality
  • Convenience
  • Recommend

Maintenance supervisor

The guys were patient and courteous with staff and residents

  • Overall Experience
  • Quality
  • Convenience
  • Recommend

Maintenace Supervisor

easy to work with, good attitude,

  • Overall Experience
  • Quality
  • Convenience
  • Recommend

Maintenance director

Zack was fast and polite. He knew what he was doing and had no issues completing the work.

  • Overall Experience
  • Quality
  • Convenience
  • Recommend

Miantenace Supervisor

I like these guys

  • Overall Experience
  • Quality
  • Convenience
  • Recommend

Prompt service, issue resolved.

  • Overall Experience
  • Quality
  • Price
  • Convenience

great

He was great, early for the appointment and did a nice job.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Friendly customer service work was done in a timely manner.

Punctual, troubleshoots very well.

  • Overall Experience
  • Quality
  • Price
  • Convenience

SEAN WAS VERY INFORMATIONAL AND HAD A GREAT PERSONALITY!


Response from Fire Pros & Fire Systems of Michigan:

Wow, thanks Dawn for the feedback and we appreciate your 5 star review.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Maintenance Manager

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for portage, mi

Tyler H.

Tyler H. Job Checkin

Annual Fire Alarm Inspection (27 devices) (Firelite MS 1OUD)


Tyler H.

Tyler H. Job Checkin

FACP is currently being monitored by TYCO through 2 dedicated phone lines. It is being monitored using a Honeywell vista 128-FBPN. We should be able to install a Telguard to the vista panel to switch to commercial monitoring. QUOTE Commercial fore for a cell install. - repair


Tyler H.

Tyler H. Job Checkin

Louisha called (269-883-2188) said the panel keeps going off- said it's showing telco tbl


Tyler H.

Tyler H. Job Checkin

Annual Fire Alarm Inspection FACP in Electrical Room by Riser Room Edwards IO Series, 5 boosters, 13 smokes, 2 heats, 11 manual pulls, 33 hornstrobes, 22 stobes, 90 A/v’s (in room av’s) 45 rooms total - 2 av’s per room.


William S.

William S. Job Checkin

COMMERCIAL FIRE PAPERWORK ATTACHED: Install the cover that is missing on the concealed sprinkler head in the Cafe (8' ladder needed).


Tyler H.

Tyler H. Job Checkin

Annual Fire Alarm Inspection.


Art L.

Art L. Job Checkin

Portable Extinguishers Inspection


Mike R.

Mike R. Job Checkin

**Commercial Fire Paperwork** Annual Fire Alarm Inspection


Tyler H.

Tyler H. Job Checkin

Per email from Becky, they have an ongoing issue with a fire alarm panel beeping off and on throughout the day. Call Becky when on your way- 269-344-8686


Sean W.

Sean W. Job Checkin


William S.

William S. Job Checkin

Perform a 5-year Hydrostatic test on the Fire Department Connection (FDC). NFPA 25 (13.8.5) The piping from the fire department connection to the fire department connection check valve shall be hydrostatically tested at 150psi (10 bar) for 2 hours at least once every 5 years.


Tyler H.

Tyler H. Job Checkin

Annual Fire Alarm Inspection.


William S.

William S. Job Checkin

Remove and replace a section of the 4" sprinkler piping that has a temporary patch due to a leak. The location of the piping is in a tight area and will require the piping to be cut into several pieces. Access to the leak is through the kitchen on the 2nd floor. THe pipe is to the right on the 2nd 4" tee. During the repairs completed on 1/21/2022, the tech found that there was a leak on 4" sprinkler piping in the attic. Attic access is in the dining room in hall E1 by Scott's office. Tech will replace a section of the sprinkler piping.


Tyler H.

Tyler H. Job Checkin

This quote is to replace the bad Door Holder BY LAUNDRY ROOM 7769 . This device failed on the inspection and needs to be REPLACED - repair


Tyler H.

Tyler H. Job Checkin

Annual Fire Alarm Inspection 1 FACP, 3 smokes, 4 manual pulls, 3 Av's Bi-Annual Sensitivity Testing (3 smokes)