I have been working with Fire Pros for 3 years and Gary was by far the best associate you have to work with. He was very professional and knowledgeable and we completed 95% of the yearly inspections in 1 day
Overall Experience
Quality
Convenience
Recommend
Overall Experience
Quality
Convenience
Recommend
The service technician is always prompt, and professional. Real easy going, and is ready to answer any questions i have.
Overall Experience
Quality
Convenience
Recommend
Overall Experience
Quality
Convenience
Recommend
Overall Experience
Quality
Price
Convenience
Overall Experience
Quality
Price
Convenience
Overall Experience
Quality
Price
Convenience
Overall Experience
Quality
Price
Convenience
Gerald walked me through my entire system while doing his inspections. Helped tremendously!
Response from Fire Pros | Fire Systems of MI | Adam's Fire | M&M | R.P. Biederman:
Thank you for leaving a review, we greatly appreciate your feedback! Gerald is an awesome asset and we want to create value for you and your organization, Thanks again and have a fire safe day! Also if you have time, please visit Google and leave us a review there as well, we would greatly appreciate it!
Overall Experience
Quality
Price
Convenience
Overall Experience
Quality
Price
Convenience
Overall Experience
Quality
Price
Convenience
Overall Experience
Quality
Price
Convenience
ANNUAL FIRE ALARM INSPECTION (1) Fire Lite MS-9200UD: 7 manual pull stations, 33 smoke detectors, 15 horn strobes, 1 NAC booster panel. CELLULAR DIALER: 850.00 INSTALLATION OF CELL UNIT:
TRUCK SERVICE FEE (1) ANNUAL FIRE EXTINGUISHER INSPECTION (9) ANNUAL EMERGENCY LIGHT INSPECTION (15) 90 MIN LOAD TEST Portable Extinguishers and Emergency / Exit Lights Inspection
Sprinkler, Obstruction Investigation, and Hydrostatic Testing Repair
Deficiency: Number of Systems failed : 2 DELI: 1. PCL-300 KK2 system requires manual pull station to be at 42”-48”, pull station is currently at 57” MUST be lowered to acceptable range (will need to move abc fire extinguisher) 2. Electrical under hood does not shut down upon system activation (will need electrician to repair) 3. Need to repipe nozzles out 10” to be over the hazard when fryers are pushed back… BAKERY: 1. Need to repipe nozzle drops out 18” to be over hazard. Deficiency: Number of Systems failed : 2 FRYER HOOD: Electric and Make-up air DO NOT shut down upon system activation Pull station mounted at 56” BAKERY HOOD: Pull station mounted at 56” (2) appliance nozzles need 18” nipples w/chrome sleeves for proper location over donut fryer Semi-annual Kitchen Suppression System Inspection (PCL 3.0 gal) (PCL 2.4 gal) Kitchen Suppression Inspection
Portable Extinguishers and Emergency / Exit Lights Inspection
Portable Extinguishers Inspection Annual Fire Extinguisher Inspection (12 FE)