FIRE PRO'S HAS ALWAYS BEEN A GOOD COMPANY TO HAVE ON BOARD WITH OURS.THEY HAVE DONE OUR FIRE PROTECTION FOR MANY YEARS ,AND THEY HAVE ALWAYS DONE A VERY GOOD JOB FOR US.
Response from Fire Pros & Fire Systems of Michigan:
Thanks for the feedback Rob.
Gary does a great job of taking care of our fire protection for our building. He made recommendations on new LED Exit lighting to help reduce power consumption which in turn will reduce our power bill each month. Great service, friendly and knowledgable. I would high recommend Gary & Fire Pro's.
Response from Fire Pros & Fire Systems of Michigan:
Thank you for leaving a review, we greatly appreciate your feedback! Gary is an awesome asset and we want to create value for you and your organization! In the meantime, please consider reviewing us on Google as well. https://tinyurl.com/yylegs7q Thanks again and have a fire safe day!
Our company received its annual inspection today. Staff was friendly and did a great job!
Gary from FirePros does a great job inspecting and helping us maintain our equipment and update as necessary!
Completed fire extinguisher inspection
Per call from Ron there is a leak in the sprinkler pipe on the nw corner in riser room.
Maint Room / ITV: Air Handler Room - 2nd Floor: Perform a 5-year internal assessment of system piping that is due. If an obstruction is present, this can render the sprinkler system not properly operate in the case of a fire. NFPA 25 (14.2.1.1) An assessment of the internal condition of piping shall be conducted at a minimum of every 5 years or in accordance with 14.2.1.2 to inspect for the presence of foreign organic and inorganic material. Maint Room / ITV: Air Handler Room - 2nd Floor: Perform a 5-year internal inspection of the Fire Department Connection (FDC) check valve. NFPA 25 (13.4.2.1) Check valves shall be inspected internally every 5 years to verify that all components operate correctly, move freely, and are in good condition. Maint Room / ITV: Air Handler Room - 2nd Floor: Replenish the spare sprinkler heads in the spare headbox. NFPA 25 (5.4.1.5.4) The stock of spare sprinklers shall include all types and ratings installed and shall be as follows; Facilities havin
Annual Fire Extinguisher Inspection (7 FE) Portable Extinguishers Inspection
Annual Fire Extinguisher Inspection (6 FE) Portable Extinguishers Inspection
Annual Fire Extinguisher Inspection (5 FE) Portable Extinguishers Inspection
Annual Fire Extinguisher Inspection (23 FE) Semi-annual Kitchen Suppression System Inspection (PCL 1.6gal AB) (PCL 3gal)
Annual Fire Extinguisher Inspection (25 FE) Semi-annual Kitchen Suppression System Inspection (Ansu R102 1.5gal +3gal AB) Portable Extinguishers and Kitchen Suppression Inspection
Annual Fire Extinguisher Inspection (4 FE) Portable Extinguishers Inspection
Annual Fire Extinguisher Inspection (2 units) Portable Extinguishers Inspection