3/7/24 Confirmed by Veronica DH / Sent email regarding inspection DH Annual Sprinkler System Inspection (2) systems Sprinkler Inspection
2/28/24 Scheduled with Larry. Tech arrival at 5:00 AM PROMPT. They will meet you on site. All 3 systems are in the same kitchen on the 4th floor. Larry is working with Alarm Company to get alarms in test, but would like you to see if the panel can be put into "walk test" so we don't have to light up the entire building from now on. km Kitchen Suppression and Portable Extinguishers Inspection Inspect Three Ansul 3 gl systems Annual Fire Extinguisher Inspection in kitchen only Deficiency: Number of Extinguishers Left at Job: 2
Sprinkler Service Call Bob Clark 248-670-8429 needs the sprinkler head & escutcheon replaced in the kitchen by the dishwasher. He also needs 2 escutcheons for the heads in the walk in freezer plus he wants (4) extra escutcheons.
2/26/24 Confirmed with Candido for 2/27/24 at 8:00am DH Fire Pump Inspection Monthly Fire Pump Churn Test PO #20440388
1/17/23(TJV)- spoke with Mark on pricing Mark to get with customer to confirm charge 1/5/24 Confirmed with Mark with Mark from Eagle for 1/31/24 DH Sprinkler Inspection Annual Sprinkler Inspection Deficiency: Sprinkler system is due for gauge change 1- sprinkler gauge Deficiency: Control valves and inspectors test valves will need signs 6-control valve signs 6- inspectors test valve signs Deficiency: Sprinkler system is due for internal obstruction investigation of piping. This will have to be done in stairwells. 4-2.5” victaulic couplings Deficiency: Sprinkler system is due for internal inspection fire department, connection check valve Red rubber gasket material Deficiency: Sprinkler system is due for five-year Hydro test of fire department. Connection access is a little suspect will have to be investigated to make sure it can be done. Red rubber gasket material Deficiency: Sprinkler system is due for gauge change 1- sprinkler gauge Deficiency: Sprinkler system is due for in
1/17/24 Confirmed with Candido for 1/22/24 at 1:00pm DH Fire Pump Inspection Monthly Fire Pump Churn Test PO #20440388
1/4/24 Confirmed with Griff W. for 1/11/24 at 11/:15am DH / Sent email regarding service DH Sprinkler Repair The tech will remove and replace the outdated water gauges. NFPA 25 (13.2.7.2) Gauges shall be replaced every 5 years
Sprinkler Inspection Annual Sprinkler Inspection ***COMMERCIAL FIRE PAPERWORK/WO REQUIRED***
1/4/24 Sent email regarding inspections DH Sprinkler Inspection Quarterly Sprinkler Inspection