2710 Northridge Dr. Suite #F
Grand Rapids, MI 49544
1-800-968-2871

Our Top Cities


Local Reviews
for southfield, mi

Rated 5.0 out of 5 stars based on 43 customer reviews

Scheduled Maintenance on Server room suppression system

Very professional and knowledgeable. He answers all my questions.

  • Overall Experience
  • Quality
  • Convenience
  • Recommend

Excellent Service

Very professional. Kind and considerate.

  • Overall Experience
  • Quality
  • Convenience
  • Recommend

Very Pleased

So far, my experience with George and Fire Systems of Michigan has been stellar!

  • Overall Experience
  • Quality
  • Convenience
  • Recommend

Great Experience

FSM is prompt and responsive. Their employees seem to be exceedingly knowledgeable about their field and working with them is a pleasure.

  • Overall Experience
  • Quality
  • Convenience
  • Recommend

HSE

Very cordial, knowledgeable and attentive to my questions.

  • Overall Experience
  • Quality
  • Convenience
  • Recommend

System upgrade

  • Overall Experience
  • Quality
  • Convenience
  • Recommend

Inspection

  • Overall Experience
  • Quality
  • Convenience
  • Recommend

Great

  • Overall Experience
  • Quality
  • Convenience
  • Recommend

Great Services

  • Overall Experience
  • Quality
  • Convenience
  • Recommend

Great Service

  • Overall Experience
  • Quality
  • Convenience
  • Recommend

Maintenance Director

Your Tech did a great job

  • Overall Experience
  • Quality
  • Convenience
  • Recommend

Awesome Service

Alex was very polite and professional. He was knowledgeable about the service he provided and gave specifics about what to expect with the next visit.

  • Overall Experience
  • Quality
  • Convenience
  • Recommend

Great Service

The tech is awesome

  • Overall Experience
  • Quality
  • Convenience
  • Recommend

Very efficient.

Dave did a very nice job, easy to work with.

  • Overall Experience
  • Quality
  • Convenience
  • Recommend

Very efficient and personable crew.

  • Overall Experience
  • Quality
  • Convenience
  • Recommend

Job Locations
for southfield, mi

Sean W.

Sean W. Job Checkin


Alex H.

Alex H. Job Checkin


John  R.

John R. Job Checkin


Terrence  J.

Terrence J. Job Checkin

The tech will remove and replace the outdated water gauges. NFPA 25 (13.2.7.2) Gauges shall be replaced every 5 years The fire sprinkler piping is due for its 5-year internal obstruction inspection. The purpose of the internal inspection is to view the condition of the piping to identify whether foreign organic and inorganic material is present since the presence of such material can potentially be detrimental to the performance of the sprinkler system. NFPA 25 (14.2.1.1) An assessment of the internal condition of piping shall be conducted at a minimum of every 5 years or in accordance with 14.2.1.2 to inspect for the presence of foreign organic and inorganic material. The fire department connection check valve is due for the 5-year internal inspection. The tech will open the check valve and verify that the valve is clear of debris and sludge so the valve works properly. NFPA 25 (13.4.2.1) Check valves shall be inspected internally every 5 years to verify that all components o


Robert G.

Robert G. Job Checkin


Terrence  J.

Terrence J. Job Checkin

Sprinkler Service Call Service call for (2) heads in Freezer / FM called out


Terrence  J.

Terrence J. Job Checkin

Sprinkler Service Call Service call for (2) heads in Freezer / FM called out


Terrence  J.

Terrence J. Job Checkin

8/18/23 Just do the sprinkler as we can no longer complete backflows DH Sprinkler Inspection Annual Fire Sprinkler System Inspection Deficiency: Missing concealed wrench in spare head box. (1) concealed head wrench for Victaulic V3802 concealed pendants Deficiency: Control valves are not identified. (2) control valve signs Deficiency: Control valves are not identified. (2) control valve signs Deficiency: Missing concealed wrench in spare head box. (1) concealed head wrench for Victaulic V3802 concealed pendants


Terrence  J.

Terrence J. Job Checkin

8/14/23 Sent email regarding inspection DH Sprinkler Inspection Annual Sprinkler Inspection


Terrence  J.

Terrence J. Job Checkin

8/14/23 Confirmed with John H. via Scott M. from kitchens DH Sprinkler Inspection Annual Sprinkler Inspection (1 Main Wet Sprinkler System) Deficiency: System is due for gauge change. 1- wet sprinkler gauge Deficiency: Sprinkler system is due for a five-year internal obstruction investigation. 2- 4” Victaulic couplings Deficiency: System is due for a hydrotest fire department connection Deficiency: Sprinkler system is due for internal inspection of fire department connection check valve. 2- 4” Victaulic couplings Deficiency: Drive pending heads in cooler in freezer I do to be replaced. 2- 155° chrome pendant dry barrel sprinkler heads.


Sean W.

Sean W. Job Checkin


Sean W.

Sean W. Job Checkin


Alex H.

Alex H. Job Checkin


George S.

George S. Job Checkin


Terrence  J.

Terrence J. Job Checkin

Sprinkler Service Call Russ, emailed regarding a leak in the storage room wants TJ specifically