The tech will remove and replace the outdated water gauges. NFPA 25 (13.2.7.2) Gauges shall be replaced every 5 years The fire sprinkler piping is due for its 5-year internal obstruction inspection. The purpose of the internal inspection is to view the condition of the piping to identify whether foreign organic and inorganic material is present since the presence of such material can potentially be detrimental to the performance of the sprinkler system. NFPA 25 (14.2.1.1) An assessment of the internal condition of piping shall be conducted at a minimum of every 5 years or in accordance with 14.2.1.2 to inspect for the presence of foreign organic and inorganic material. The fire department connection check valve is due for the 5-year internal inspection. The tech will open the check valve and verify that the valve is clear of debris and sludge so the valve works properly. NFPA 25 (13.4.2.1) Check valves shall be inspected internally every 5 years to verify that all components o
Sprinkler Service Call Service call for (2) heads in Freezer / FM called out
Sprinkler Service Call Service call for (2) heads in Freezer / FM called out
8/18/23 Just do the sprinkler as we can no longer complete backflows DH Sprinkler Inspection Annual Fire Sprinkler System Inspection Deficiency: Missing concealed wrench in spare head box. (1) concealed head wrench for Victaulic V3802 concealed pendants Deficiency: Control valves are not identified. (2) control valve signs Deficiency: Control valves are not identified. (2) control valve signs Deficiency: Missing concealed wrench in spare head box. (1) concealed head wrench for Victaulic V3802 concealed pendants
8/14/23 Sent email regarding inspection DH Sprinkler Inspection Annual Sprinkler Inspection
8/14/23 Confirmed with John H. via Scott M. from kitchens DH Sprinkler Inspection Annual Sprinkler Inspection (1 Main Wet Sprinkler System) Deficiency: System is due for gauge change. 1- wet sprinkler gauge Deficiency: Sprinkler system is due for a five-year internal obstruction investigation. 2- 4” Victaulic couplings Deficiency: System is due for a hydrotest fire department connection Deficiency: Sprinkler system is due for internal inspection of fire department connection check valve. 2- 4” Victaulic couplings Deficiency: Drive pending heads in cooler in freezer I do to be replaced. 2- 155° chrome pendant dry barrel sprinkler heads.
Sprinkler Service Call Russ, emailed regarding a leak in the storage room wants TJ specifically