2710 Northridge Dr. Suite #F
Grand Rapids, MI 49544
1-800-968-2871

Our Top Cities


Local Reviews
for sturgis, mi

Rated 5.0 out of 5 stars based on 1 customer reviews

Very friendly and courteous

Mike did a great job when he was here and worked with us to make it a smooth morning.


Response from Fire Pros Inc:

Thank you for leaving a review, we greatly appreciate your feedback! Mike is an awesome asset and we want to create value for you and your organization! In the meantime, please consider reviewing us on Google as well. https://tinyurl.com/yylegs7q Thanks again and have a fire safe day!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for sturgis, mi

Brandon  F.

Brandon F. Job Checkin


Tyler H.

Tyler H. Job Checkin

DIV3=test stand alone smokes annually (8 detectors)


Ron  R.

Ron R. Job Checkin

See Tiffany - they used to put a magnet on a strip above fire panel to do a drill test. The magnet is there but does not work after the panel was replaced in June. See if we can hook up the magnet to do drills OR show her how to do a drill from new panel. Write up instructions when done. Also check zone 4 , it was in trouble but cleared when she hit the reset button. See Tiffany on site .


Tyler H.

Tyler H. Job Checkin

EMCOR Paperwork Attached Annual Fire Alarm Inspection (51 devices)


Tyler H.

Tyler H. Job Checkin

Deficiency for FACP KITCHEN: FACP IS STUCK IN BATTERY TROUBLE. CHARGING CIRCUIT IS AT 25.2,I REPLACED BATTS, THEY ARE 12.7/12.8VOLTS. PANEL WILL STILL NOT CLEAR. TRIED TO POWER CYCLE PANEL BUT STILL STUCK IN TROUBLE. I RECOMMEND REPLACING THE FACP. Deficiency for FACP KITCHEN: FACP IS STUCK IN BATTERY TROUBLE. CHARGING CIRCUIT IS AT 25.2,I REPLACED BATTS, THEY ARE 12.7/12.8VOLTS. PANEL WILL STILL NOT CLEAR. TRIED TO POWER CYCLE PANEL BUT STILL STUCK IN TROUBLE. I RECOMMEND REPLACING THE FACP. 1 NAC, 4 ZONES. FIRELITE MS-4


Mike R.

Mike R. Job Checkin

Annual Fire Alarm Inspection (30 devices) (Edwards 2400)


Mike R.

Mike R. Job Checkin

Annual Fire Alarm Inspection (7 devices) (ESL 1500) Sensitivity Testing (2 smoke detectors) done in 2017- due in 2019 To do smoke sensitivity use a magnet and count the number of flashes on the smoke LED.For smoke model 429c For 2WB use the i3 tool


Art L.

Art L. Job Checkin

Portable Extinguishers Inspection


Austin C.

Austin C. Job Checkin


Gerald N.

Gerald N. Job Checkin

Alarm Systems Inspection


Chad B.

Chad B. Job Checkin


Logan W.

Logan W. Job Checkin


Chris P.

Chris P. Job Checkin


Chris P.

Chris P. Job Checkin


Matthew K.

Matthew K. Job Checkin