Tech was courteous, showed up early and was very knowledgable. Testing was completed quickly and paperwork the next morning. Much appreciated.
Sean did an excellent inspection. He was thorough and efficient.
When I mentioned that I almost always run into the extinguisher in its current placement, the tech offered to move it for us while he was here to rechargs the extinguisher. Thanks!
Robert was very nice and courteous,He knew what he was doing and talking about
Jared came back to my property to install all our new fire extinguishers in our end rooms. Jared was fast but very efficient getting the job done. Jared was friendly and knowledgeable once again during the install. I will recommend you all for years to come!
I've been in the property management business for almost 10 years and the Fire systems tech Jared that came out to my property was the BEST!!! he was friendly and professional and very knowledgeable in his work. I will definitely be referring Fire Systems to friends and family in the business.
Always good at calling and scheduling appointments and keeping our maintenance schedule worry free!
Sean was very nice to work with very professional and personable.
Response from Fire Pros | Fire Systems of MI | Adam's Fire :
Thank you for leaving a review, we greatly appreciate your feedback! Sean is an awesome asset and we want to create value for you and your organization! In the meantime, please consider reviewing us on Google as well. https://tinyurl.com/yylegs7q Thanks again and have a fire safe day!
3/7/24 Confirmed with Bryan C. for 3/11/24 at 11:30AM. dh / Sent email regarding inspection DH Sprinkler Inspection Annual Sprinkler Inspection (1 Wet Sprinkler System) 5-Year Internal Due: 2024 FDC Hydro Due: 2024 Suggested: Receiving office is not protected recommend installing protection in this area. Lift is required. 1- 1 1/2” x 1” jack tee or a 4” x 1” 21’-0” 1” 2- 1” 90 1- 1” t 1- 1” plug 1- 1”x 1/2” RC 1- 1/2” 155 QR HSW w/ esc 3/8” tbc 3/8” ATR 1” loop rings Deficiency: 155° QR chrome pendants are older than 20 years old x 4 of them need to be pulled and sent in for UL testing Deficiency: Receiving office is not protected recommend installing protection in this area. Lift is required. 1- 1 1/2” x 1” jack tee or a 4” x 1” 21’-0” 1” 2- 1” 90 1- 1” t 1- 1” plug 1- 1”x 1/2” RC 1- 1/2” 155 QR HSW w/ esc 3/8” tbc 3/8” ATR 1” loop ring Deficiency: Sprinkler system is due for five year internal inspection, fire department, connection, check valve 2- 4” victaulic couplings Deficiency
TECHNICIAN - Please have manager open a Corrigo work order if there are any deficiencies so a quote can be submitted. TECHNICIAN - YOU MUST CHECK IN/OUT ON THE CORRIGO APP PER GREG FUCHS. Sprinkler Inspection Annual Sprinkler Inspection
2/2/24 confirmed with Kevin SM Kevin 734-776-2164 Portable Extinguishers and Emergency / Exit Lights Inspection Annual Fire Extinguisher Inspection (10) Annual Exit Emergency Light Inspection (23) Deficiency: Combo lights in small child left front and right front need to be replaced. Combo lights inside and outside of art room need to be replaced. Comb light by rear door.
11/2/23 confirmed with mike See natalie. SM Portable Extinguishers Service Call 1 new 5 LB ABC and Trouble shoot Emergency Exit Lights.