2710 Northridge Dr. Suite #F
Grand Rapids, MI 49544
1-800-968-2871

Our Top Cities


Local Reviews
for westland, mi

Rated 5.0 out of 5 stars based on 10 customer reviews

Awesome job

  • Overall Experience
  • Quality
  • Convenience
  • Recommend

Fire extinguisher service

Jarrod from Fire Systems of Michigan serviced our fire extinguishers at our facility and I cannot be more satisfied. He was very kind and knowledgeable. He spent time to show me what to look for to keep our animals and staff safe in the case of a fire.

  • Overall Experience
  • Quality
  • Convenience
  • Recommend

Great service, very helpful!

  • Overall Experience
  • Quality
  • Convenience
  • Recommend

Great Service

Prompt and professional.

  • Overall Experience
  • Quality
  • Convenience
  • Recommend

Great Service!

  • Overall Experience
  • Quality
  • Convenience
  • Recommend

Excellent Service!

We had our annual fire extinguisher inspection today. It is always a pleasure to have this completed by Jared. He is extremely knowledgeable and efficient.

  • Overall Experience
  • Quality
  • Convenience
  • Recommend

Great Service

Arrived on time! Was very thorough on coaching staff on how to use the alarm system in every possible scenario!

  • Overall Experience
  • Quality
  • Price
  • Convenience

A+++

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service thank you

He was a great technician he checked everything on all our fire extinguishers very detailed on all his work while being a true professional thank you very much please send him back next year

  • Overall Experience
  • Quality
  • Price
  • Convenience

General Manager

Good service

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for westland, mi

Robert G.

Robert G. Job Checkin


Mark S.

Mark S. Job Checkin


Terrence  J.

Terrence J. Job Checkin

10/20/22 Confirmed with Wanda K via email for 10/21/22 / Sent email regarding inspection DH Sprinkler Inspection Quarterly Flow Inspection


Mark S.

Mark S. Job Checkin


Terrence  J.

Terrence J. Job Checkin

9/28/22 Confirmed with Lindsey via cell for 10/4/22 at 8:00am DH Sprinkler Inspection Annual Fire Sprinkler Inspection (1 Wet System) Deficiency: No evidence of 5 year internal pipe obstruction investigation. Deficiency: There is no evidence of five-year FDC check valve inspection. Deficiency: There is no evidence of five-year FDC hydrostatic test. Deficiency: Missing stortz cap. Deficiency: Control valve tampers do not operate. Will need chain and lock. Deficiency: Gauges are outdated. Deficiency: Missing ITV sign. In back of pharmacy. Deficiency: Missing control valve sign. Deficiency: Suggested sprinkler adjustments need.


Terrence  J.

Terrence J. Job Checkin

9/28/22 Confirmed with Lindsey via cell for 10/4/22 at 8:00am DH Sprinkler Inspection Annual Fire Sprinkler Inspection (1 Wet System) Suggested for Riser Counts: Sprinkler located above tread mills is obstructed recommend installing protection for proper coverage. Lift required 1- 2x1 jack t 1- 1” 90 1- 1” Criticom 1- 1/2” 155 SR brass upright 21-0” 1” 3- 1” loop rings for trap hanger 4- 3/8” tbc 3/8 atr Deficiency: No evidence of five-year internal pipe obstruction investigation. Deficiency: No evidence of 5 year FDC check valve inspection. Deficiency: No evidence of 5 year FDC hydrostatic test. Deficiency: FDC stortz connection missing cap. Deficiency: Gauge is outdated. Deficiency: Missing inspectors tests sign. Deficiency: Painted sprinkler heads need to be removed and replaced with new heads. Deficiency: Improper amount/style of spare sprinkler heads. Deficiency: Missing outer esc found in pool store sales floor Heads may need to be cut longer / head ext. Deficiency: Recommend


Terrence  J.

Terrence J. Job Checkin

9/28/22 Confirmed with Lindsey via cell for 10/4/22 at 8:00am DH Sprinkler Inspection Annual Fire Sprinkler Inspection (1 Wet System) Deficiency: Sprinkler system is due for gauge change. Deficiency: Sprinkler system is due for five-year internal inspection of fire department connection check valve. Deficiency: Sprinkler system is due for five year internal obstruction investigation. Deficiency: Sprinkler system control valves need chain and lock. Deficiency: Five-year Hydro test is due on fire department connection. Deficiency: Fire department connection is missing STORTZ cap. Deficiency: Inspector‘s test valve needs sign. Deficiency: Fire department connection needs sign on wall outdoors. Deficiency: Systems will need signs for all devices main drain control valves fire department connection the whole shot. Deficiency: Fire sprinkler headbox will need proper heads to complete 📦. Deficiency: The half of store has removed a drop ceiling and heads will need to be adjusted to cover thi


Terrence  J.

Terrence J. Job Checkin

Sprinkler Inspection Annual Fire Sprinkler Inspection (1 Wet System) Deficiency for Riser Counts: Dry pendants are outdated and shall be replaced with new. 2x 12” dry 155 SR dry pendants Deficiency: Sprinkler system will need breakaway lot and chain for control valve along with sign Deficiency: Sprinkler system do for gauge change. Deficiency: Sprinkler system do for internal check of check valve fire department connection as well as system. Deficiency: Fire alarm system has been gutted and does not work at all Deficiency: Fire sprinkler system do for five-year internal obstruction investigation. Deficiency: Sprinkler heads are painted and will need to be replaced. Deficiency: Improper style/amount of spare sprinkler heads.


Terrence  J.

Terrence J. Job Checkin

9/28/22 Confirmed with Lindsey via cell for 10/4/22 at 8:00am DH 9/14/22 Sent email regarding inspection. DH Sprinkler Inspection Annual Fire Sprinkler Inspection (1 Wet System) Deficiency: There is no evidence of five-year internal inspection fire department connection check valve Deficiency: System does not have inspectors test valve sign Deficiency: Sprinkler system head box needs the proper heads in the box. Deficiency: Sprinkler system will need chain and lock for valves. Deficiency: System will need gauge change. Deficiency: System due for five year Hydro test on fire department connection. Deficiency: Fire sprinkler system will need five year internal of struction investigation. Deficiency: Sectional shut off valve will need chain lock and sign to identify. Deficiency: Please remove foil from sprinkler heads in Napa auto parts.


George S.

George S. Job Checkin


Terrence  J.

Terrence J. Job Checkin

Sprinkler Inspection Annual Fire Sprinkler Inspection (1 Wet System) 5-Year Internal Due: FDC Hydro Due:


George S.

George S. Job Checkin


Robert G.

Robert G. Job Checkin


Mark S.

Mark S. Job Checkin


Terrence  J.

Terrence J. Job Checkin

8/8/22 Sent email regarding inspection DH Sprinkler Inspection Annual Fire Sprinkler Inspection (1 Wet System)