2710 Northridge Dr. Suite #F
Grand Rapids, MI 49544
1-800-968-2871

Our Top Cities


Local Reviews
for westland, mi

Rated 5.0 out of 5 stars based on 10 customer reviews

Awesome job

  • Overall Experience
  • Quality
  • Convenience
  • Recommend

Fire extinguisher service

Jarrod from Fire Systems of Michigan serviced our fire extinguishers at our facility and I cannot be more satisfied. He was very kind and knowledgeable. He spent time to show me what to look for to keep our animals and staff safe in the case of a fire.

  • Overall Experience
  • Quality
  • Convenience
  • Recommend

Great service, very helpful!

  • Overall Experience
  • Quality
  • Convenience
  • Recommend

Great Service

Prompt and professional.

  • Overall Experience
  • Quality
  • Convenience
  • Recommend

Great Service!

  • Overall Experience
  • Quality
  • Convenience
  • Recommend

Excellent Service!

We had our annual fire extinguisher inspection today. It is always a pleasure to have this completed by Jared. He is extremely knowledgeable and efficient.

  • Overall Experience
  • Quality
  • Convenience
  • Recommend

Great Service

Arrived on time! Was very thorough on coaching staff on how to use the alarm system in every possible scenario!

  • Overall Experience
  • Quality
  • Price
  • Convenience

A+++

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service thank you

He was a great technician he checked everything on all our fire extinguishers very detailed on all his work while being a true professional thank you very much please send him back next year

  • Overall Experience
  • Quality
  • Price
  • Convenience

General Manager

Good service

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for westland, mi

Terrence  J.

Terrence J. Job Checkin

Sprinkler Repair COMMERCIAL FIRE PAPERWORK: The fire sprinkler system control valve is not monitored. The tech will add supervision of the valve. This will prevent tampering with. NFPA 25 (13.3.1.3) Each normally open valve shall be secured utilizing a seal or a lock or shall be electrically supervised in accordance with applicable NFPA standards. Deficiency: Missing supervision for control valve Small lock and change


Terrence  J.

Terrence J. Job Checkin

4/3/24 Customer cancelled inspection for 4/5/24 per Kathy M. DH 2/28/24 Sent email regarding inspection DH and also regarding backflow DH Sprinkler Inspection Annual Fire Sprinkler Inspection (1 Wet System)


John  S.

John S. Job Checkin


Sean W.

Sean W. Job Checkin


James J.

James J. Job Checkin


Sean W.

Sean W. Job Checkin


Terrence  J.

Terrence J. Job Checkin

Sprinkler Service Call Derek called in a service call for leaking heads please call when in route 330-671-1520


Terrence  J.

Terrence J. Job Checkin

2/27/24 Confirmed with Niko for 2/28/24 in the afternoon. DH / Sent email regarding inspection DH Sprinkler Inspection Annual Sprinkler Inspection Deficiency: Sprinkler system number one is due for internal obstruction investigation of piping. 2- victaulic couplings Deficiency: Sprinkler system number one is due for internal inspection of check valve. Fire department connection. 2- victaulic couplings Deficiency: Sprinkler system number one is due for Hydro test fire department connection. 1- victaulic coupling Deficiency: Dry pendant, heads in cooler are due to be replaced. 4–286° chrome pendant adjustable, sprinkler heads quick response these are dry pendant heads Deficiency: Sprinkler system number two is due for five-year internal obstruction investigation of piping. 2- 4” victaulic couplings


James J.

James J. Job Checkin


Terrence  J.

Terrence J. Job Checkin

2/8/24 Sent email regarding inspection DH 12/29/23MV Emailed Henry regarding inspection date 1/4, waiting on confirmation 12/13/23MV Henry confirmed Sprinkler Inspection Annual Fire Sprinkler Inspection (1 Wet System) Deficiency: There is no evidence of five-year internal obstruction investigation piping Red gasket material Deficiency: Sprinkler head box will need universal wrench 1- universal head wrench Deficiency: Fire department connection will need new stortz cap. 🧢 1- 4” stortz connection cap Deficiency: Sprinkler system is due for gauge change. 2- sprinkler gauges. Deficiency: There is no evidence of five-year fire department connection Hydro test. Red gasket material Deficiency: Alarm check valve has no evidence of five-year internal inspection. Red gasket material Deficiency: Fire department connection, check valve has no evidence of five-year internal inspection. Red gasket material Deficiency: Control valves, as well as inspectors test valve will need signs


Terrence  J.

Terrence J. Job Checkin


Terrence  J.

Terrence J. Job Checkin

1/26/24 Sent email regarding inspection DH Sprinkler Inspection Annual Fire Sprinkler Inspection (1 Wet System) 5yr Internal Due: 2026 FDC Hydro Due: 2026


Mark S.

Mark S. Job Checkin


Matt P.

Matt P. Job Checkin


Terrence  J.

Terrence J. Job Checkin

1/5/24 Mater in Shop in Novi / DH Sent email regarding inspection DH Sprinkler Repair The tech is to install the FDC ring indicator per Edward Snorf's request. For the ring to be installed the connection will be removed and then replaced.