Jarrod from Fire Systems of Michigan serviced our fire extinguishers at our facility and I cannot be more satisfied. He was very kind and knowledgeable. He spent time to show me what to look for to keep our animals and staff safe in the case of a fire.
We had our annual fire extinguisher inspection today. It is always a pleasure to have this completed by Jared. He is extremely knowledgeable and efficient.
Arrived on time! Was very thorough on coaching staff on how to use the alarm system in every possible scenario!
He was a great technician he checked everything on all our fire extinguishers very detailed on all his work while being a true professional thank you very much please send him back next year
Sprinkler Repair COMMERCIAL FIRE PAPERWORK: The fire sprinkler system control valve is not monitored. The tech will add supervision of the valve. This will prevent tampering with. NFPA 25 (13.3.1.3) Each normally open valve shall be secured utilizing a seal or a lock or shall be electrically supervised in accordance with applicable NFPA standards. Deficiency: Missing supervision for control valve Small lock and change
4/3/24 Customer cancelled inspection for 4/5/24 per Kathy M. DH 2/28/24 Sent email regarding inspection DH and also regarding backflow DH Sprinkler Inspection Annual Fire Sprinkler Inspection (1 Wet System)
Sprinkler Service Call Derek called in a service call for leaking heads please call when in route 330-671-1520
2/27/24 Confirmed with Niko for 2/28/24 in the afternoon. DH / Sent email regarding inspection DH Sprinkler Inspection Annual Sprinkler Inspection Deficiency: Sprinkler system number one is due for internal obstruction investigation of piping. 2- victaulic couplings Deficiency: Sprinkler system number one is due for internal inspection of check valve. Fire department connection. 2- victaulic couplings Deficiency: Sprinkler system number one is due for Hydro test fire department connection. 1- victaulic coupling Deficiency: Dry pendant, heads in cooler are due to be replaced. 4–286° chrome pendant adjustable, sprinkler heads quick response these are dry pendant heads Deficiency: Sprinkler system number two is due for five-year internal obstruction investigation of piping. 2- 4” victaulic couplings
2/8/24 Sent email regarding inspection DH 12/29/23MV Emailed Henry regarding inspection date 1/4, waiting on confirmation 12/13/23MV Henry confirmed Sprinkler Inspection Annual Fire Sprinkler Inspection (1 Wet System) Deficiency: There is no evidence of five-year internal obstruction investigation piping Red gasket material Deficiency: Sprinkler head box will need universal wrench 1- universal head wrench Deficiency: Fire department connection will need new stortz cap. 🧢 1- 4” stortz connection cap Deficiency: Sprinkler system is due for gauge change. 2- sprinkler gauges. Deficiency: There is no evidence of five-year fire department connection Hydro test. Red gasket material Deficiency: Alarm check valve has no evidence of five-year internal inspection. Red gasket material Deficiency: Fire department connection, check valve has no evidence of five-year internal inspection. Red gasket material Deficiency: Control valves, as well as inspectors test valve will need signs
1/26/24 Sent email regarding inspection DH Sprinkler Inspection Annual Fire Sprinkler Inspection (1 Wet System) 5yr Internal Due: 2026 FDC Hydro Due: 2026
1/5/24 Mater in Shop in Novi / DH Sent email regarding inspection DH Sprinkler Repair The tech is to install the FDC ring indicator per Edward Snorf's request. For the ring to be installed the connection will be removed and then replaced.