Justin was very professional and personal. Another example of the great service and wonderful staff at Charlie’s!
Very professional and courteous. Always great
Awesome, expert service. I never allow anyone but Charlie’s to service my heating/cooling equipment.
PCSA 2022 Heating Check Up Prepaid<br> Everything was clean and checked out well. System is operating normally at this time.
PCSA 2022 Heating Check Up Renewal. Both gas furnaces are heating efficiently at this time. Downstairs filter is changed, upstairs filter is changed as needed by customer. Temperature rises are acceptable, all hoses and drains are clear, and flame sensors are clean.
Complaint: No Heat Need to order pressure switch. Manometer achieving .62 every time pressure switch calls for .3 and will intermittently open while in sequence of operations. 11/02/22 furnace fired 4 times in a row after pressure switch replaced. Unit heating at this time.
Complaint customer thinks a/c low on freon. Added R-22 by superheat.
We are waiting on his coil. His house is 84. Check freon for him to get him cooling. Added 2 lb 410. Replaced coil and recharged system. System is operating normally at this time.
NO AC - Not Blowing Air ReplCed bat thermostat and bad contactor
NO AC - Heard a sound like a line blew. System was completely out of Puron upon arrival. Added nitrogen to system to try to track down leak. Leak is massive and most likely inside flex lineset. Leak may also be inside indoor coil but not seeing any signs of oil. A full leak search would need to be scheduled for a more exact location. Gave customer an estimate around $2000 for replacement of lineset. Left outdoor coil disconnect off and service valves closed.
Complaint no a/c Found leak in evaporator coil. Needs replaced under warranty , model and serial in system. Added another lb of 410A
PCSA 2022 a/c check up renewal. System was not running up to full efficiency at time of arrival due to dirty condenser coil and low on R410A. Cleaned coil and added 1lb of R410A. is running efficiently at this time, drain is flushed and filter is changed.
No AC - Outside unit kicks off then won't come back on . Bug in contactor switch.
PCSA 2022 a/c check up prepaid 2 system South system needed 1 lb of R-22. Everything else was clean and checked out well. Both systems are operating normally at this time.
PCSA 2022 a/c check up Everything was clean and checked out well. System is operating normally.
Topped off charged by superheat. No warranty until leak is repair , which would not be economical.
Heat & AC Repair Contractor - PCSA 2022 a/c maintenance renewal