PCSA FREE With Install 2 System AC Check Up. Both systems check out good and are running efficiently, filters are clean, outdoor coils are clean, and drains are flushed. Upstairs system needed a new capacitor, replaced and verified operation.
2022 Spring Check Up PCSA Prepaid Everything was clean and checked out well. System is operating normally at this time.
PCSA 2022 a/c check up renewal . Completed Spring Pm unit in good order. Cleaned return new filter customer stock.
Found that outdoor condenser fan motor was bad, replaced with temporary motor and verified operation, need to order new motor and replace.
Complaint outside unit making noise. Checked capacitor on outdoor coil. Capacitor is within normal operating range. System was 3 lbs low on R-22. Outdoor coil needed cleaned. Customer will clean coil in the near future. Fan motor on outdoor coil is a little worn but still operational. Customer will monitor and let us know of any changes. Customer will mail check for bill. System is operating normally at this time.
PCSA 2022 a/c check up renewal. System checks out good, filter is clean and outdoor coil is clean
PCSA 2022 a/c check up prepaid Everything was clean and checked out well. System is operating normally at this time.
Gave estimate to install 3 ton AC unit as well as option for 2 1/2 ton Air Conditioner
2022 Spring Check Up PCSA New Customer wanted to sign up for service plan. System needed 1 lb of R-22. Capacitor on outdoor coil was weak. Replaced capacitor. Everything else was clean and checked out well. System is operating normally at this time.
PCSA 2022 PREPAID AC CHECK UP. System is running efficiently at this time
PCSA 2022 AC check up. System checks out good, temperature drop is acceptable, outdoor coil is clean and filters are changed by customer.
Heat Repair - Unit not running right, huge pressure drop after orifice in heating mode. Most likely restriction. Non condensables also causing fluctuation in pressures. All other checks good. Steve is aware of issues and is coming out to repair. Filter replaced. 3/1 Steve returned and pumped down system, removed and cleaned orifice, removed and installed new filter drier. Pressure tested system, no leaks, pulled 500 micron vacuum on refrigerant lines and indoor coil.
PCSA 2021 heating maintenance 2 systems free w/ install Upstairs outdoor coil may need a new capacitor in the near future. Everything else was clean and checked out well. Both systems are operating normally at this time.