Daniel was great no complaints with him he is nothing but very good at his work
Justin was very friendly & thorough. He let me know what was going on with each thing he checked.
Justin came on time and did a very good servicing my air conditioner.
I called early today and the Tech was here earlier than expected which was great the Tech had my air conditioner fixed in less than one hour. I can't say enough how pleased I am with the service.
Daniel came out, was very friendly as always and did a thorough job of cleaning and checking our system.
Daniel installed the system earlier this year. Had great service during installation and system check. Thank you.
Daniel was very thorough. He checked everything, and cleaned the drain lines. We were very satisfied with the service we received today.
Great service! Steve was very thorough & explained all that he checked.
Replaced ECM blower motor, washed coil, cleaned blower wheel, made sure system is working properly, system is cooling at this time
Completed cooling maintenance, cleaned condenser coil, flushed drain, replaced filter, checked blower amps, checked blower capacitor, checked compressor and outdoor fan amps, checked capacitor, upon arrival temp drop was 13° and after adding a pound of 410a temp drop was 23°. Made sure system is working properly System is cooling at this time
Heat Pump / Furnace Maintenance Customer would like PCSA. Customer has had questions answered about heat pump operation and provided filter for replacement. Customer has been notified about r-22 production and availability. Replaced dual run cap. All checks good. Heating at this time.
No heat return duct had collapsed, cut the 14 inch piece and sheathed it with 16 inch to get her by for now, need to build a quote to return and replace the 14 inch flex and strap it up. Still was tripping limits so cheated blower door temporarily to keep it heating 2/15/23 Steve Replaced flex run, strapped it up best we could, unit heating great
PCSA 2022 Heating Check Up Renewal Blower noise coming from insulation caught in blower. Removed loose insulation from cabinet. Blower checks good. Justin coming later to put back together and perform maintenance. Put furnace back together and perform maintenance, filters change, and customers bought four filters so they got two free per the buy two get one free deal. System is heating efficiently at this time.
PCSA 2022 Heating Check Up Renewal Main high temperature limit is tripping well below set point. Temperature in supply won’t go above 125 degrees. Would recommend replacement when possible. Everything else was clean and checked out well.
Removed old gas line from fireplace and checked for leaks. Nothing was detected. Customer needs to have drain line coming from bathroom repaired. Line was cut too short and it is trying to separate from fittings. Thad Ellot was present making another repair so they were informed of the situation.
PCSA 2022 Heating Check Up Prepaid. Gas furnaces is heating efficiently at this time, temperature rise is acceptable and filter is changed. Screw had come loose where flue pipe attaches to inducer motor leaving mild opening just enough for water to leak through, causing mild puddle in cabinet of system. Cleaned up water and re-tightened screw for flue pipe. Coupling for condensate line had also come loose causing water to drip from it. Re-attached and verified no water was leaking out of condensate line. Tested carbon monoxide detector and verified its operation. System checks out good at this time.
Furnace Maintenance & 20x25x5 Filter Change Full maintenance performed and filter changed. Unit heating at this time
2022 Fall Check Up PCSA <br> Furnace #13 had a completely clogged drain line. Cleaned and flushed drain. Furnaces #9 and #14 have louder inducer motors and are hot during operation. Will continue to monitor during future check ups. Furnace #1 is occasionally tripping on high limit. Furnace #4 needs a new flame sensor. Current one is broken at the mounting base. North Package Unit is showing a high temperature rise and CO reading coming from the flue is extremely high indicating the burners aren’t firing correctly. <br> <br> 10/12/22 Cleaned burners and inspected heat exchanger on north Package Unit. No signs of damage to heat exchanger and burners appear to be operating normally. We will continue to monitor. <br> <br> 1/6/22 Replaced and programmed thermostats for north and south sanctuary systems, lobby, office, and stage. Discovered south Package Unit had a blown transformer. The reason this has gone unnoticed is because the thermostat has been drawing power from backup battery and t
PCSA 2022 Heating Check Up Prepaid. Upon maintenance found that inducer motor was going bad and needs replaced. Ordered an inducer motor and will schedule a time to come replace and finish maintenance. 1-12-23 Replaced inducer motor and edifies operation. Finished check up and verified system is running at this time.
PCSA 2022 Heating Check Up Renewal Completed heating maintenance, checked air temps in heat pump and electric heating mode, filter is in good condition, checked blower and electric heat amps, checked blower capacitor Checked compressor and outdoor fan amps, checked capacitor, forced defrost successfully System is heating at this time
2022 Fall Check Up PCSA New<br> Cause of the issue was a sagging drain line. Adjusted and cleaned drain line. Everything else was clean and checked out well. System is operating normally at this time.
PCSA 2022 Heating Check Up Prepaid Blower capacitor was getting weak and needed replaced. Adaptor going from collector box to inducer motor is cracked and needs to be replaced. Sealed leaks with high temperature silicone to help prevent leak from getting worse until replacement part arrives. 11/30/22 Replaced fitting and system is operating normally at this time. Not seeing anymore water dripping.
Gave quote for install of 3 ton AC unit and 95% gas furnace