Way too expensive
I woke up hot and sticky yesterday so I called the gang down at Charlie’s. Daniel came straight over and got my apartment cooled down…….but not me! After he had been bent over by the furnace for awhile, it took a glass of lemonade to cool us both down. Daniel was there all afternoon servicing my needs and then some. He is a very thorough and thoughtful young man. I would highly recommend him to all my gals. Sincerely, Phyllis
Cause of the issue was bad blower motor. Replaced blower motor and capacitor. System is operating normally at this time.
Complaint no a/c the unit was blowing out warm air t-stat was set @ 77* and it was 98* in apartment. Cause of the issue was a bad connection on the reversing valve which was causing the system to go from AC to Heat Pump mode randomly. Redid connection and system appears to be operating normally at this time.
2020 AC Check Up Renewed & Done 6/9/20 2020 Heating Check Up Prepaid & Done 10/12/20 2021 AC Check Up Renewed & Done 7/15/21 2021 Heating Check Up Prepaid & Done 2/21/22 2022 AC Check Up Renewal Blower capacitor and outdoor coil capacitors were both very weak and needed replaced. System needed close to 1 lb of R-22 to work at peak efficiency. Everything else was clean and checked out well. System is operating normally at this time. Cause of high electric bill appears to be poor insulation inside manufactured home walls and ceiling. Didn’t see any signs of damaged duct work under the house causing air loss based on a quick glance.
2022 Spring Check Up PCSA New Outside Unit not coming on after power failure yesterday. Cause of the issue was bad capacitor on outdoor coil. Replaced capacitor. System needed 1 lb of R-22. Customer wanted to sign up for service plan. Would recommend replacing contactor on outdoor coil next AC check up. Everything else was clean and checked out well. System is operating normally at this time.
AC not cooling. Replaced filter and cleaned outdoor coil for full air flow. System could be slightly overcharged. None of the electric heaters were on. Lowered blower speed and checked temperatures and pressures. Temperature drop is about 17 degrees. System appears to be operating normally at this time. Tenant will monitor for any changes in operation.
Water issue. Cause of the issue was clogged drain line. Cleaned drain line and vacuumed water out of return. Filter was replaced recently, temperature drop is within range, and pressures look normal. System is operating normally at this time.
PCSA 2022 RENEWAL - AC Check Up. System checks out good and is running efficiently, filters are changed and outdoor coil is clean
PCSA 2022 Prepaid AC Check Up Hard start capacitor on outdoor coil was cracked and showing signs of wear. Replaced hard start. Everything else was clean and checked out well. System is operating normally at this time.
PCSA 2022 a/c check up prepaid Everything was clean and checked out well. System is operating normally at this time.
2022 Spring Check Up PCSA Prepaid Everything was clean and checked out well. System is operating normally at this time.
Giving price to replace AC unit with 13 SEER air conditioning unit and evap coil
Ckd codes on new furnace, ok. Washed condenser. Noted mice issue.
PCSA AC ONLY Check Up Hard start capacitor on outdoor coil was leaking oil everywhere. Replaced hard start. Everything else was clean and checked out well. System is operating normally at this time.