PCSA 2022 Heating Check Up Renewal<br> All checks are good. Filter is clean and changed monthly.
Pulled and cleaned coil. Fixed drain and put in a filter
Complaint no heat Only way this coil can be cleaned is if the coil is pulled and taken outside to be washed off. Neither cooling nor heating will function properly with this issue. Shooting for tomorrow on schedule. Tenant has been informed and says she will leave door unlocked
Complaint water issue Drain not clogged. Pan was clogged. The inside edge of the drain pan under the evap coil has a very small channel for water to run through. It was slimed up. I flushed it all out and put some drain tablets in. No drip at this time. I also replaced her filter upon request. It was due.
PCSA 2022 PREPAID AC CHECK UP All checks good, made new screw holes for blower door, filter changed by customer
Sealed shield with silicone, replaced both capacitors, ran a mini drain to keep water off the curb. All checks good, 26 degree rise
No cool ductwork is rotted under house, needs box fixed, 2 sections of trunk, radius elbow and remove all work. Told customer we’re 2 months out, they would like it scheduled