Thank you for your professionalism and friendly service. See you in the winter.
Furnace Service Heating Maintenance PCSA 2024 Heating Check Up Prepaid Completed heating maintenance, cleaned flame sensor, flushed drain, filter is provided by customer, checked system operation, found weak inducer capacitor, replaced capacitor and made sure system is working properly System is cooling at this time
AC Repair Replaced bad fan relay. Seemed like filter was dirty enough there could have been water or ice dripping off coil. Recommended replacing filters and giving coil a good scrub with toothbrush or other soft bristled brush
2024 PSCA AC Check Up Free w. install AC Maintenance Verified cooling operation, flushed out condensate drain, checked filter and cleaned outdoor coil. Added 6 oz of 410A
Checked air flow issues Air Conditioning Installation
AC Inspection Complaint a/c not operating properly not cooling. Burnt wire on outside unit. Have not confirmed compressor operation. Blower motor is bad. Some high voltage starting to become exposed outside. Customer is flipping house and requests possible new system, relocation of system and duct, gasline and flues run etc. Pete coming Thursday at 1 pm.
One-time Check Up AC Maintenance - flushed drain, cleaned condenser, and verified pressures. Signed customer up for pcsa and left sign
Gas Furnace Repair Complaint of furnace not kicking on all they way. Gas furnace failure to ignite, after checking solenoid signal and outgoing gas pressure determined gas would not feed burners properly. Cleaned sediment out of spud and got gas to feed and all burners to ignite, cleaned flame sensor as a courtesy. Furnace got all the way to blower and would not come on. New capacitor got motor to start with extremely labored startup. Best call was to go ahead and change motor to avoid callback. Blower motor and capacitor replaced and heating speed set to medium. Unit fires at this time no issues
AC Maintenance PCSA 2023 AC Check Up Prepaid Completed cooling maintenance, cleaned coils, flushed drain, filter is provided by customer, checked air temps, checked compressor and condenser fan amps, checked capacitor, made sure system is working properly System is cooling at this time
Complaint: No AC - No air blowing through vents. System was not running due to 24v wire being hit and split by weed-eater. Repaired wires and verified operation of system. It is cooling at this time.
Complaint No AC. System was low on refrigerant again, added 4lbs and verified it had a good temp drop and proper sub cool. There is definitely a leak in the system, bubbled a few joints and couldn’t find one. We need to get back out here ASAP and perform a thorough leak search.
AC Repair Complaint: No AC Found unit cycling on low pressure switch, added 3 lbs 410a. Unit holds 8 lbs so it’s apparent there is a leak. Looked over unit, no signs of leaks, checked service valves, no leaks. Would recommend coming back and doing a leak search. In the meantime, system is cooling
Quote for AC repair vs. Air Conditioner replacement