Found boiler attempts to start but strike plate for pilot spark ignition is missing causing system to not spark to ignite recommend replacement of pilot assembly. Ordered 2-6 days
Performed heating maintenance tune up service on three heat pump systems checking all electrical, refrigerant balance, unit start up, operation, defrost, shutdown, cleaning of drain lines. Everything looks and runs great!
Performed heating maintenance tune up service on two dual fuel systems checking all electrical components, refrigerant balance, unit start up, light off, operation, and shutdown. Cleaning of furnace burners and flame sensors, flushing condensate box, trap, and treatment of condensate lines. Checking of all furnace safeties, gas pressure, performed full combustion analysis on furnaces checking Flue gas temperature, CO, CO2, and O2 in furnace flue. Everything looks and runs great!
System making loud noises during boiler operation - found system boiling violently with a lot of sediment in the boiler, drained boiler down, filled with water and refired boiler til boiling, drained again, and filled system until sight glass cleared. Cycled system and ran until all supplies and returns came back hot. Exercised all valves, checked all safeties, performed boiler tune up service checking gas pressure, performed full combustion analysis, cleaned boiler burners and flame sensor. Everything looks and runs great! Will return with sight glass valve handle to replace one that broke during tune up service.
Found insulation off of suction line in basement by post. Nothing is oily so no refrigerant leak just condensation. I wrapped it with foam insulation tape and black tape on top of that to hold it in place.
Replacement of thermostat and programming of thermostat settings - performed full system diagnostic after replacing system thermostat to ensure proper operation of all equipment. Everything looks and runs great!
Found emergency drain pan full of water and the unit still running. Check the drain line trap to see if it was clear of debris. Didn’t see anything that would cause it not to drain. I put a vacuum on the drain trap thinking maybe something was Blocking the drain pipe after the condensate trap. Removing water from the emergency drain pan using a pump Sending the water into the drip drain under the humidifier. At this point, the water didn’t drain either. My guess is there’s something wrong with the plumbing. I pulled the Studer vent off, thinking maybe it needed to be vented and it was bad. This didn’t work. Talk to the plumber about it. He was gonna run a snake through there. I also confirmed with him that he was going to take care of this issue that it was OK for me to go ahead and turn the unit back on. Found the float switches were hooked to red and G on the air handler, which is where the manufacturer says float switches should be hooked up. I talked to Kevin and he said to Gr
Performed a tune up and safety check on boiler for potable hot water. System is in great condition and is working exactly as it should. Checked combustion, cleared condensate line.
Found unit condensate pump running but not pumping - replaced condensate pump - performed unit AC maintenance tune up service on AC system checking all electrical components, refrigerant balance, unit start up, operation, shutdown, cleaning of indoor and outdoor coils, cleaned dehumidifier filter, changed unit media filter, everything looks and runs great!
Ultimate Cooling Tune-Up: cleaned coils, brushed and cleaned traps, added pan treatment tablets to pan. tested and checked all controls, wiring connections. tested temperatures, checked filters. checked refrigerant temperature and pressures, tested static duct pressure. tested blower operation, tested cooling operation to ensure working within manufacturer specifications. Filter in the attic looks like it’s good won’t have to be changed. The one that’s in the basement will have to be replaced on the next tuneup. Replace battery in 2nd floor bedroom
Ultimate Cooling Tune-Up: cleaned coils, brushed and cleaned traps, added pan treatment tablets to pan. tested and checked all controls, wiring connections. tested temperatures, checked filters. checked refrigerant temperature and pressures, tested static duct pressure. tested blower operation, tested cooling operation to ensure working within manufacturer specifications. Guesthouse was a little low on charge. Charged it to manufacture specs. Also went into crawl to check dampers and eccomizer for Theater room. Didn’t find any issues
Cabana system down - found system thermostat not receiving power from indoor unit took off base and reset - thermostat started up again - updated thermostat software and reinstalled thermostat to reset system specific settings. After thermostat reinstallation cycled system to check operation - everything looks and runs great! Performed AC maintenance tune up service on system checking all electrical components, refrigerant balance, unit start up, operation, shutdown, cleaning of indoor and outdoor coils and treatment of drain lines.
Performed AC cooling tune ups on 3 heat pump systems checking all electrical components, refrigerant balance, units start up, operation, shutdown, cleaning of indoor and outdoor units and coils, checking of system filters, treatment of system drain lines, added algae tablets to all drain pans. Reset lights, doors, furniture, attic accesses, and system electrical disconnects and thermostats. Everything looks and runs great! Both main house indoor air filters look like they will last until fall. No recommended changes at this time!
AFUE 94% Make: Weil McLain Model: Ultra 155 Boiler Aqua-Plus 45 Indirect Water Heater Installation shall include: Equipment specified above plus materials and labor to include: • This system will replace the existing boiler and water heater. • All necessary plumbing, pumps, gas pipe and electrical is included. • All work will be completed in a professional workmanlike manner. • Old equipment and trash from installation will be removed from premises. • Weil McLain maunfacturer’s warranty: 5 years all parts; 12 years on heat exchanger. • One (1) Year Labor Warranty Provided by Comfort Central, Inc.