Knowledgeable, professional and always has latest tools...
Cameron is friendly and helpful, listens to any questions/ concerns and addresses them. I just need maintenance, it’s always handled well and there’s lots of communication to make sure I know when he’s coming
Cameron is knowledgeable, polite and easy to work with. Always a pleasure.
Cameron was pleasant and very knowledgeable and checked both systems to ensure they were working at peak operation. He is a pleasant conversationalist and answered all my questions and left me with the confidence knowing my systems were in good hands.
Comfort Central installed a cooling/heating system in our home in one day with no issues, it works great. They are one of the best contractors we have ever used.
Performed cooling tune up service on both the Bosch and Mitsubishi systems checking all electrical components, refrigerant balance, unit start up, operation, shutdown, cleaning of indoor and outdoor coils, treatment of drain lines. Everything looks and runs great!
Customer called about a loud banging noise from their hydronic heating system. Diagnosed a faulty zone valve on the Weil-McLain boiler. Performed the boiler repair by replacing the valve and purging air from the affected loop. System now heats silently and effectively.
Serviced a geothermal heat pump system that was showing a low pressure fault. Found a minor leak at a loop fitting. Repaired the fitting, then performed a full loop flush and recharge with new antifreeze solution. The geothermal system is now holding pressure and operating at peak efficiency.
Customer reported no heat from their gas furnace. Performed diagnostic and found a failed hot surface ignitor. Completed furnace repair by replacing the ignitor assembly. Customer also approved a full-system duct cleaning to improve airflow and reduce dust. Furnace now heats properly and air quality is improved.
Found contactor welded shut - replaced contactor and cycled syste to check operation
Performed cooling tune up service on heat pump system checking all electrical components, refrigerant balance, unit start up, operation, shutdown, cleaning of indoor and outdoor units, treatment of drain. Changed customer provided filter 12x20x1. Everything looks and runs great!
Performed AC cooling tune up service on heat pump system checking all electrical components, refrigerant balance, unit start up, operation, shutdown, cleaning of indoor and outdoor coils, treatment of drain. Everything looks and runs great!
Found Mitsubishi unit operating normally - took out of emergency operation mode - performed check of communications and thermisters - found system attempts to overshoot in auto mode but functions normally in heat only. Recommended watch it for a couple days and report back when we return for our tune up service.
Performed heating maintenance tune up service on heat pump system checking all electrical components, refrigerant balance, unit start up, operation, defrost, shutdown. Everything looks and runs great!
Performed AC maintenance tune up service on heat pump system checking all electrical components, refrigerant balance, unit start up, operation, shutdown, cleaning of indoor and outdoor coils, and treatment of drain pan and drain line. Replaced customer provided filter. Everything looks and runs great!
Found compressor bad drawing locked rotor amps 100 amps + and kicking out - tried hard start kit which brought compressor on ranging at 20-25 amps which far exceeds FLA of compressor recommended replacement of system - will call with pricing and availability of replacement compressor - set up estimate for Friday at 10 am to price replacing the system.
Performed AC tune up service for Bosch and Mitsubishi systems checking all electrical components, refrigerant balance, unit start up, operation, shut down, cleaning of indoor and outdoor unit, cleared drain line and treated condensate pump, everything looks and runs great!
No heat caused by filter needing to be changed removed filter and cycled to check operation. Performed heating maintenance tune up on system checking all electrical components, refrigerant balance, unit start up, operation, shut down, defrost. Everything looks and runs great! Will return first am 2/20 to replace filter.
Delta T of 19 in HP mode. 45 in emergency heat. Checked burners. Brushed out trap. Put algae tablets in condensate pump. Changed filter. Ran combustion analysis. CO 8 ppm, O2 9.1 %, Tstac 99 F. Coil is clean. Tested all dampers. System is functioning normally.
Found common wire had come apart in indoor u it separating t Stat indoor unit and outdoor unit not allowing system to cycle on when calling. Redid the wiring on the common wire and checked connections of all other low voltage fittings. Everything operates normally again. If issue persists don't hesitate to give a call.