Cameron  S.

Cameron S. Job Checkin

Performed heating maintenance tune up service on heat pump system checking all electrical components, refrigerant balance, unit start up, operation, defrost, shutdown. Everything looks and runs great!


Cameron  S.

Cameron S. Job Checkin

Performed AC maintenance tune up service on heat pump system checking all electrical components, refrigerant balance, unit start up, operation, shutdown, cleaning of indoor and outdoor coils, and treatment of drain pan and drain line. Replaced customer provided filter. Everything looks and runs great!


Cameron  S.

Cameron S. Job Checkin

Found compressor bad drawing locked rotor amps 100 amps + and kicking out - tried hard start kit which brought compressor on ranging at 20-25 amps which far exceeds FLA of compressor recommended replacement of system - will call with pricing and availability of replacement compressor - set up estimate for Friday at 10 am to price replacing the system.


Cameron  S.

Cameron S. Job Checkin

Performed AC tune up service for Bosch and Mitsubishi systems checking all electrical components, refrigerant balance, unit start up, operation, shut down, cleaning of indoor and outdoor unit, cleared drain line and treated condensate pump, everything looks and runs great!


Cameron  S.

Cameron S. Job Checkin

No heat caused by filter needing to be changed removed filter and cycled to check operation. Performed heating maintenance tune up on system checking all electrical components, refrigerant balance, unit start up, operation, shut down, defrost. Everything looks and runs great! Will return first am 2/20 to replace filter.


Kelsey T.

Kelsey T. Job Checkin

Delta T of 19 in HP mode. 45 in emergency heat. Checked burners. Brushed out trap. Put algae tablets in condensate pump. Changed filter. Ran combustion analysis. CO 8 ppm, O2 9.1 %, Tstac 99 F. Coil is clean. Tested all dampers. System is functioning normally.


Cameron  S.

Cameron S. Job Checkin

Found common wire had come apart in indoor u it separating t Stat indoor unit and outdoor unit not allowing system to cycle on when calling. Redid the wiring on the common wire and checked connections of all other low voltage fittings. Everything operates normally again. If issue persists don't hesitate to give a call.


Cameron  S.

Cameron S. Job Checkin

Found system stuck saying it was calling for cooling but not supplying 24v to unit. Performed a hard power cycle on both indoor and outdoor unit circuit breakers and cycled system to check operation. Everything came on normally. Cycled 3 times from thermostat to insure systems continued operation.


Cameron  S.

Cameron S. Job Checkin

COLEMAN HEAT PUMP - Found condensate pump had failed replaced condensate pump and cycled to check operation


Kelsey T.

Kelsey T. Job Checkin

Blower fault. New blower and board ordered. Advanced diagnostic lvl 1.


Jay E.

Jay E. Job Checkin

System was low on 410a. Charged system to manufactures specs.. tested temps. No other issues found.


Kevin S.

Kevin S. Job Checkin

Delta T of 18-22 on both units. Subcool of 11, superheat of 13 on Bosch. Homeowner mentioned rattling at AC condenser; turned out to be plastic fan cover on top of unit. Filter needs to be replaced. Filters clean in Mitsubishi power head. Treated all coils with coil cleaner. Systems are functioning normally.


Kevin S.

Kevin S. Job Checkin

Discovered condenser motor failing. Swapped out old condenser fan motor for new one. System is functioning normally now.


Jay E.

Jay E. Job Checkin

Spring tune up. Found bad capacitor . Found some oxidation on blower board but seem like no issue right now


Cameron  S.

Cameron S. Job Checkin

Performed Ultimate Cooling Tune-Up on two Trane heat pump systems in Horse Shoe

Performed Ultimate Cooling Tune-Up on two Trane heat pump systems in Horse Shoe