We had Comfort central install a new Mini-Split system in our cottage as well as service the existing unit in our house. On both occasions the workers were exactly on time despite the early hour. I am very technically minded so I could appreciate their professionalism, knowledge of the product (even before the sale was concluded) and neatness (shoe protectors, tarp on the ground, sweep after themselves and not a single scuff mark on the walls or the floor). In addition, they work very well as a team, even under very adverse conditions - South side in full sun on a 90 degree day - and they are every funny with each other yet most respectful with me, the client, answered every question thoroughly and knowledgeably. I recommend them without any reservation at all and, even though I could have possibly paid less elsewhere I am glad that I chose them.
The service was great, he couldn’t have been nicer! He explained everything that even I could understand! And he was even nice to my dog! He also gave me the size of the filter for easy re ordering. That was super thoughtful of him!!
Inspected and maintained a Lennox heat pump for a homeowner, ensuring proper airflow and verifying defrost cycle operation for cold weather.
Tune up on Mitsubishi heat pump and 4 heads. No issues found
Found capacitor on heat pump to be bad causing the compressor not to start. Cheacked refrigerant and vacuumed out drain line Ultimate Cooling Tune-Up: cleaned coils, brushed and cleaned traps, added pan treatment tablets to pan. tested and checked all controls, wiring connections. tested temperatures, checked filters. checked refrigerant temperature and pressures, tested static duct pressure. tested blower operation, tested cooling operation to ensure working within manufacturer specifications.
Replaced defrost board and temperature sensor on outdoor unit. Tested system operation, system is now working properly
Condenser Door was put back incorrectly on last tune up visit leaving a gap. Corrected door issue. Homeowner is going to have her tune up in the spring.
Replaced zone actuator on hot water boiler zone number three. Tested operation from thermostat. Selected high temperature for boiler to 180° from 160°. This will make the baseboard radiators get hotter faster.
End switch not closing on zone 3 common area. While thermostat is calling. Need to replace Honeywell hot water zone actuator valve.
SEER2 26.3, HSPF 11.1 EER 13.8 Make: Mitsubishi Model: MUZ-FS12NAU1 Outdoor Unit MSZ-FS12NAU1 Indoor Unit Mounting rack Installation shall include: Equipment specified above plus materials and labor to include: • Permit Fee for Installation. • We will pull and clean the blower wheel on the existing indoor unit that is next door. • Necessary electrical is included. • All work will be completed in a professional workmanlike manner. • Old equipment and trash from installation will be removed from premises. • Mitsubishi Manufacturer’s Warranty: Twelve (12) Year Limited Parts, including Compressor. • One (1) Year Labor Warranty Provided by Comfort Central, Inc.
Delta T of 21. Changed filter. Brushed out drain line Checked temps, pressures, and amps. SC 8 SH 14. Cleaned condenser unit. System is functioning normally.
Installed Goodman two stage gas furnace with a good man single stage heat pump. Honeywell prestige 3.0 thermostat
Volvo maintenance on two propane gas Bernices train manufacturer 90% of the fish it systems
Fall maintenance on two propane train gas versus 90% efficient systems safety checks on the systems check the gas pipe gas pipe yard
cleared a blocked drain on a carrier heat pump then did a ac tuneup
cleared a blocked drain on a carrier heat pump then did a ac tuneup