253 Timberlane Dr
Pisgah Forest, NC 28768
828-483-4040

Local Reviews
for mills river, nc

Rated 5.0 out of 5 stars based on 4 customer reviews

Great service

  • Overall Experience
  • Quality
  • Price
  • Convenience

Honest, on time, and Great service.

We have been using Comfort Central for a few years now and have had excellent service with Tech. Alex. He is kind, polite, and courteous, calls before he arrives, and he knows the HVAC systems. When finished, we cannot even tell he was here. Super clean and neat. The company overall is well managed and accommodating to meet our time frames and needs. We highly recommend Comfort Central and Alex to anyone who mentions HVAC. Thank you for your great service to all at Comfort Central. Peter.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great Job

Alex has been servicing our HVAC system for over a year. He is kind, clean, well mannered, and knows the equiptment very well. I would recommend him and Comfort Central to others.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent Service

First off the technician notified me that he was going to be a little early. I always appreciate when the provided service notifies me when they will be either late or early. Also, I really appreciated that he was early. He was also very thorough and explained everything to me. Very professional. Wonderful experience overall in a day where customer service is suffering.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for mills river, nc

Kelsey T.

Kelsey T. Job Checkin

Performed fall maintenance Compressor is pulling 7 amps Outdoor fan motor is pulling 1.2 amps Blower motor is pulling 1.2 amps Temperature difference between the return and supply is 28 Capacitors are within manufacturer specifications.


Kelsey T.

Kelsey T. Job Checkin

Cooling tune up Compressor is pulling 8 amps Outdoor fan motor is pulling 1 amp Capacitor is within manufacturer specifications Subcool is 12 Superheat is 12 Indoor blower is pulling .8 amps Temperature difference between return and supply is 20 Cleaned indoor and outdoor coils Cleared condensate drain System is great working condition.


Cameron  S.

Cameron S. Job Checkin

Performed AC maintenance tune up service on air conditioning system checking all electrical components, refrigerant balance, unit start up, operation, shutdown, cleaning of indoor and outdoor units, flushing and treatment of drains and condensate lines. Everything looks and runs great!


Jay E.

Jay E. Job Checkin

AHRI# 206395975 SEER2 17.5, HSPF2 8.2; EER2 11.7 Make: Bosch Model: BOVB36HDN1M18M Outdoor Unit BVA24WN1M20 Air Handler TEHK08 Electric Heat kit Honeywell T-6 Thermostat Installation shall include: Equipment specified above plus materials and labor to include: • Required Electrical for the outdoor unit is included. • We will install a Buck Thranformer and Surge Protector to protect outdoor unit. • Permit Fee for Installation. • All work will be completed in a professional workmanlike manner. • Old equipment and trash from installation will be removed from premises. • Bosch Manufacturer’s Warranty: Ten (10) Year Limited Parts, including Compressor. • One (1) Year Labor Warranty Provided by Comfort Central, Inc. • First year Comfort Club is included. • 100% Customer Satisfaction Guarantee for the first year.


Kelsey T.

Kelsey T. Job Checkin

Delta T of 23. Smell coming from unit is heat kit turning on. Adjusted blower speed. Homeowner is going to contact Champion (installer) to see if he is owed a tune up (installed last year.) System is functioning normally.


Kelsey T.

Kelsey T. Job Checkin

Delta T of 33 without heat kit. 62 with heat kit on. Tested defrost. Suction line temp of 122F with an outdoor ambient of 33F. Brushed out drain trap. Changed filter. Checked blower wheel and coils for dust and damage. No signs of over amping from blower motor or outdoor condenser fan motor. Outdoor capacitor is good. System is functioning normally.


Kelsey T.

Kelsey T. Job Checkin

Delta T of 42. Suction line temp of 148 in heat mode with an outdoor ambient of 41. All capacitors have good readings. Blower is clean. Used paint brush and wire brush to carefully remove clumps of dust from the EVAP coil. Filter has been changed. Tested pan float switch. No signs of over amping, refrigerant loss, or drain clogs. Power has been restored to the unit and the system is functioning normally.


Cameron  S.

Cameron S. Job Checkin

Performed heating tune up on gas furnace system checking all electrical components, combustion analysis, cleaning all furnace components including burners and flame sensor, flushed and treated drain and trap. Everything looks and runs great!


Kelsey T.

Kelsey T. Job Checkin

123.7 Tstac, 6 ppm CO, 9.6% O2. Burners clean. Blower clean. Blew out drain line. Fixed kink in drain hose inside furnace. Treated condensate pump with algae tablets. Treated outdoor coil with cleaner and cleaned with hose. Patched test hole in ductwork. Checked for leaks on new gas valve. System is functioning normally.


Kevin S.

Kevin S. Job Checkin

ULTIMATE COOLING AC TUNE UP - BOSCH 21 degree delta T. Subcool 10 superheat 14. Changed filter in crawlspace unit. Suction 120 psig, liquid 280 psig. Brushed out drain trap. Crawlspace is dry with no signs of leakage. Blower clean. Replaced stock valve caps with brass caps to prevent refrigerant leaks from Schrader. Treated outdoor coil with cleaner. System is functioning normally. Homeowner never received heating tune up in winter after paying for 1 year plan on heat pump system. Renewal will be during the winter/fall visit.


Jay E.

Jay E. Job Checkin

2 spring tuneups. No issues found everything is running well..Dripping sound Mitsubishi unit is transmitted through all the drain pipes from the main air handler once the drain trap on the air handler has water in it you know longer hear the dripping sound.


Jay E.

Jay E. Job Checkin

Replace a Lennox signature series heat pump with a Bosch inverter heat pump plus a Honeywell t6 thermostat

Replace a Lennox signature series heat pump with a Bosch inverter heat pump plus a Honeywell t6 thermostat

Jay E.

Jay E. Job Checkin

Air conditioning tune up on a Trane air conditioner


Jay E.

Jay E. Job Checkin

Air conditioning tune-up on a two-stage Coleman heat pump


Cameron  S.

Cameron S. Job Checkin

HVAC maintenance tune up heat pump Coleman heat pump electric central heating system